Secondary electron emission in DC operation of the retarding field analyzer

被引:1
|
作者
Nedzelskiy, I. S. [1 ]
Silva, C. [1 ]
Fernandes, H. [1 ]
机构
[1] Univ Lisbon, Inst Super Tecn, Inst Plasmas & Fusao Nucl, P-1049001 Lisbon, Portugal
来源
关键词
Plasma diagnostics - charged-particle spectroscopy; Plasma diagnostics - probes;
D O I
10.1088/1748-0221/12/11/C11019
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The DC operation of a retarding field analyzer (RFA) has been proposed for the direct measurements of the ion temperature fluctuations in the plasma scrape-off-layer [1]. The method is based on the relation for the RFA current-voltage (I-V) characteristic resulting from a common RFA model of shifted Maxwellian distribution of the analyzed ions and the measurements of two points on the exponentially decaying region of the I-V characteristic with two differently DC biased RFA electrodes. It was mentioned that the secondary electron emission (SEE) from the RFA electrodes could be a serious problem for the correct application of the method. From the experiments on the tokamak ISTTOK (R = 0.46 m, a = 0.085 m, B = 0.5 T) in ref. [1], the SEE yield for hydrogen ions was measured as gamma similar to 0.2, estimating similar to 10% contribution to the average ion temperature and assuming no influence on the measurements of ion temperature fluctuations. However, in the followed investigations it was observed that the SEE yield could be up to gamma similar to 0.5. In this paper, the influence of the secondary electron emission on the ion temperature fluctuations measurements in RFA DC mode of operation is analyzed and detection scheme improving the measurements is proposed.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] A hemispherical retarding field energy analyzer to characterize spatially and angularly extended electron beams
    Cipriani, Fabrice
    Leblanc, Frederic
    Illiano, Jean-Marie
    Berthelier, Jean-Jacques
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2012, 60 (02): : 21002-p1 - 21002-p7
  • [22] Secondary electron detection efficiency for magnetic lenses with a retarding electrostatic field
    Nakasuji, M
    Shimizu, H
    JOURNAL OF ELECTRON MICROSCOPY, 1996, 45 (05): : 359 - 363
  • [23] FALSE PEAKS IN ENERGY-DISTRIBUTION OF SECONDARY ELECTRONS MEASURED WITH A SPHERICAL RETARDING FIELD ANALYZER
    CROSS, JA
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1973, 6 (05) : 622 - 627
  • [24] Development and utilization of a retarding analyzer for field emission investigation of LaB6/W emitter
    Al-Tabbakh, Ahmed A. A.
    More, Mahendra A.
    Joag, Dilip S.
    TURKISH JOURNAL OF PHYSICS, 2013, 37 (02): : 219 - 228
  • [25] Instrumentation for a retarding potential analyzer for measurement of electron parameters
    Rajput, SS
    Garg, SC
    INDIAN JOURNAL OF ENGINEERING AND MATERIALS SCIENCES, 2002, 9 (05) : 315 - 322
  • [26] High Dynamic Range Retarding Potential Analyzer Operation Verification
    Maystrenko, D. A.
    Shagayda, A. A.
    Kravchenko, D. A.
    Tomilin, D. A.
    Selivanov, M. Yu.
    PLASMA PHYSICS REPORTS, 2024, 50 (09) : 1142 - 1157
  • [27] SOME PROBLEMS OF ELECTRON-SPECTROSCOPY (AES, EPES) USING A RETARDING-FIELD ANALYZER
    SULYOK, A
    GERGELY, G
    GRUZZA, B
    BIDEUX, L
    VACUUM, 1994, 45 (2-3) : 325 - 327
  • [28] LOCAL FIELD EFFECTS ON VOLTAGE MEASUREMENT USING A RETARDING-FIELD ANALYZER IN THE SCANNING ELECTRON-MICROSCOPY
    FUJIOKA, H
    NAKAMAE, K
    URA, K
    SCANNING ELECTRON MICROSCOPY, 1981, : 323 - 332
  • [29] Multi-channel retarding field analyzer for EAST
    Henkel, M.
    Hoeschen, D.
    Liang, Y.
    Li, Y.
    Liu, S. C.
    Nicolai, D.
    Sandri, N.
    Satheeswaran, G.
    Yan, N.
    Zhang, H. X.
    PLASMA SCIENCE & TECHNOLOGY, 2018, 20 (05)
  • [30] A SIMPLE CYLINDRICAL RETARDING-FIELD ENERGY ANALYZER
    FUJII, Y
    ISHIGURO, E
    KITADA, T
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1990, 29 (10): : 2176 - 2179