A novel energy mapping approach for CT-based attenuation correction in PET

被引:11
|
作者
Teimourian, B. [1 ,2 ]
Ay, M. R. [1 ,3 ,4 ]
Zafarghandi, M. Shamsaie [2 ]
Ghafarian, P. [5 ,6 ]
Ghadiri, H. [1 ,4 ]
Zaidi, H. [7 ,8 ,9 ]
机构
[1] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran, Iran
[2] Amirkabir Univ Technol, Tehran Polytech, Fac Phys & Nucl Engn, Tehran, Iran
[3] Univ Tehran Med Sci, Res Inst Nucl Med, Tehran, Iran
[4] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran, Iran
[5] Shahid Beheshti Univ Med Sci, Telemed Res Ctr, NRITLD, Masih Daneshvari Hosp, Tehran, Iran
[6] Shahid Beheshti Univ Med Sci, Chron Resp Dis Res Ctr, NRITLD, Masih Daneshvari Hosp, Tehran, Iran
[7] Univ Hosp Geneva, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
[8] Univ Geneva, Geneva Neurosci Ctr, CH-1211 Geneva, Switzerland
[9] Univ Groningen, Univ Med Ctr Gronigen, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
基金
瑞士国家科学基金会;
关键词
PET/CT; attenuation correction; attenuation map; energy-mapping; dual-energy CT; ARTIFACTS; IMAGES; TOMOGRAPHY;
D O I
10.1118/1.3694108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Dual-energy CT (DECT) is arguably the most accurate energy mapping technique in CT-based attenuation correction (CTAC) implemented on hybrid PET/CT systems. However, this approach is not attractive for clinical use owing to increased patient dose. The authors propose a novel energy mapping approach referred to as virtual DECT (VDECT) taking advantage of the DECT formulation but using CT data acquired at a single energy (kV(P)). For this purpose, the CT image acquired at one energy is used to generate the CT image at a second energy using calculated kV(P) conversion curves derived from phantom studies. Methods: The attenuation map (mu-map) at 511 keV was generated for the XCAT phantom and clinical studies using the bilinear, DECT, and VDECT techniques. The generated mu-maps at 511 keV are compared to the reference derived from the XCAT phantom serving as ground truth. PET data generated from a predefined activity map for the XCAT phantom were then corrected for attenuation using mu-maps generated using the different energy mapping approaches. In addition, the generated mu-maps using the above described methods for a cylindrical polyethylene phantom containing different concentrations of K2HPO4 in water were compared to actual attenuation coefficients. Likewise, CT images of five clinical whole-body studies were used to generate mu-maps using the various energy-mapping approaches were compared with mu-maps acquired at 511 keV using Ge-68/Ga-68 rod sources for the clinical studies. Results: The results of phantom studies demonstrate that the proposed method is more accurate than the bilinear technique. All three mu-maps yielded almost similar results for soft and lung tissues whereas for bone tissues, the DECT and the VDECT methods produced a much smaller mean relative difference (3.0% and 2.8%, respectively) than the bilinear approach (11.8%). Likewise, the comparison of PET images corrected for attenuation using the various methods showed that the proposed method provides better accuracy (6.5%) than the bilinear method (13.4%). Clinical studies further demonstrated that, compared to the bilinear method, the VDECT approach has better agreement for bony structures with the DECT technique (1.5% versus 8.9%) and transmission scanning (8.8% versus 17.7%). Conclusions: It was concluded that the proposed method outperforms the bilinear method especially in bony structures. Further evaluation using a large clinical PET/CT database is underway to evaluate the potential of the technique in a clinical setting. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3694108]
引用
收藏
页码:2078 / 2089
页数:12
相关论文
共 50 条
  • [31] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    David Izquierdo-Garcia
    Stephen J. Sawiak
    Karin Knesaurek
    Jagat Narula
    Valentin Fuster
    Joseph Machac
    Zahi A. Fayad
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1574 - 1584
  • [32] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    Izquierdo-Garcia, David
    Sawiak, Stephen J.
    Knesaurek, Karin
    Narula, Jagat
    Fuster, Valentin
    Machac, Joseph
    Fayad, Zahi A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (08) : 1574 - 1584
  • [33] Dual energy CT for attenuation correction with PET/CT
    Xia, Ting
    Alessio, Adam M.
    Kinahan, Paul E.
    MEDICAL PHYSICS, 2014, 41 (01)
  • [34] Comparison template-based with CT-based attenuation correction for hybrid MR/PET scanners
    Elena Rota Kops
    Hans Herzog
    N Jon Shah
    EJNMMI Physics, 1 (Suppl 1)
  • [35] Direct Reconstruction of CT-based Attenuation Correction Images for PET with Cluster-Based Penalties
    Kim, Soo Mee
    Alessio, Adam M.
    De Man, Bruno
    Asma, Evren
    Kinahan, Paul E.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [36] Comparison of different CT-based attenuation correction schemes for PET with respiratory motion.
    Qi, J
    Huesman, RH
    Reutter, BW
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 38P - 38P
  • [37] Impact of Ge-68-based versus CT-based attenuation correction on PET imaging
    van Dalen, J. A.
    Visser, E. P.
    Vogel, W. V.
    Corstens, F. H. M.
    Oyen, W. J. G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S314 - S315
  • [38] Simulation-based Assessment of the Impact of Contrast Medium on CT-based Attenuation Correction in PET
    Ay, Mohamad Reza
    Zaidi, Habib
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2731 - 2735
  • [39] Direct Reconstruction of CT-Based Attenuation Correction Images for PET With Cluster-Based Penalties
    Kim, Soo Mee
    Alessio, Adam M.
    De Man, Bruno
    Kinahan, Paul E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (03) : 959 - 968
  • [40] Effect of oral contrast agents on CT-based PET attenuation correction in dual-modality PET/CT tomography
    Antoch, G
    Jentzen, W
    Stattaus, J
    Mueller, SP
    Bockisch, A
    Debatin, JF
    RADIOLOGY, 2002, 225 : 423 - 424