Minification of fundus optical coherence tomographic images in gas-filled eye

被引:1
|
作者
Yamashita, Toshifumi [1 ]
Terasaki, Hiroto [1 ]
Sakamoto, Taiji [1 ]
机构
[1] Kagoshima Univ, Dept Ophthalmol, Grad Sch Med & Dent Sci, Kagoshima, Japan
来源
BMC OPHTHALMOLOGY | 2016年 / 16卷
关键词
Macular hole; SD-OCT; Gas-filled eye; MACULAR HOLE SURGERY; CLOSURE; TAMPONADE; THICKNESS; FEATURES; NERVE; OCT;
D O I
10.1186/s12886-016-0306-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Optical coherence tomography (OCT) is being used increasingly to evaluate and manage a variety of retinal diseases, but not much is known about the minification of the OCT images in gas-filled eyes. The purpose of this study was to investigate the effect of gas-filled eyes on the size of the OCT images. Methods: This was retrospective case series of 81 consecutive eyes of 79 patients who had macular hole surgery between April 2012 and September 2014. Images of the optic disc were taken with a spectral domain-OCT instrument 2 days after surgery in gas-filled, pseudophakic eyes and from the same eyes but fluid-filled one month after the surgery. The vertical length, horizontal width, and the area of the optic disc were measured in the OCT images. Results: Clear images were obtained from 50 eyes of 49 patients (mean age 66.4 +/- 5.9 years). The mean vertical length and mean horizontal width of the optic disc in the gas-filled eyes were about 25 % shorter than that of fluid-filled eyes (vertical, 1213.8 +/- 170.5 and 1650.6 +/- 195.9 mu m, P < 0.01; horizontal, 1169.4 +/- 143.1 and 1526.4 +/- 219.9 mu m, P < 0.01). The mean area of the optic disc was 1.12 +/- 0.34 mm(2) in gas-filled eyes which was significantly smaller than that in fluid-filled eyes (1.88 +/- 0.37 mm(2)) by 40.4 %. Conclusions: The fundus images of gas-filled eyes are significantly smaller than that in the same fluid-filled eyes. The minification of the OCT images should be considered when analyzing images obtained from gas-filled eyes.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Kago-Eye2 software for semi-automated segmentation of subfoveal choroid of optical coherence tomographic images
    Sonoda, Shozo
    Terasaki, Hiroto
    Kakiuchi, Naoko
    Shiihara, Hideki
    Sakoguchi, Tomonori
    Tomita, Masatoshi
    Shinohara, Yuki
    Yamashita, Takehiro
    Uchino, Eisuke
    Sakamoto, Taiji
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2019, 63 (01) : 82 - 89
  • [32] Technique to alter field of view during vitrectomy with phacoemulsification and aspiration in gas-filled eye
    Oyagi, T
    Emi, K
    Futamura, H
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (05) : 935 - 937
  • [33] Binarization of enhanced depth imaging optical coherence tomographic images of an eye with Wyburn-Mason syndrome: a case report
    Iwata, Akiko
    Mitamura, Yoshinori
    Niki, Masanori
    Semba, Kentaro
    Egawa, Mariko
    Katome, Takashi
    Sonoda, Shozo
    Sakamoto, Taiji
    BMC OPHTHALMOLOGY, 2015, 15
  • [34] Binarization of enhanced depth imaging optical coherence tomographic images of an eye with Wyburn-Mason syndrome: a case report
    Akiko Iwata
    Yoshinori Mitamura
    Masanori Niki
    Kentaro Semba
    Mariko Egawa
    Takashi Katome
    Shozo Sonoda
    Taiji Sakamoto
    BMC Ophthalmology, 15
  • [35] Kago-Eye2 software for semi-automated segmentation of subfoveal choroid of optical coherence tomographic images
    Shozo Sonoda
    Hiroto Terasaki
    Naoko Kakiuchi
    Hideki Shiihara
    Tomonori Sakoguchi
    Masatoshi Tomita
    Yuki Shinohara
    Takehiro Yamashita
    Eisuke Uchino
    Taiji Sakamoto
    Japanese Journal of Ophthalmology, 2019, 63 : 82 - 89
  • [36] Enhancement and quantitative measurement of layer structures in optical coherence tomographic images
    Department of Optoelectronic Engineering, Ji'nan University, Guangzhou 510632, China
    不详
    Guangxue Xuebao, 2007, 3 (515-520):
  • [37] A Dynamic Wavelet Filtering for Anterior Chamber Optical Coherence Tomographic Images
    Du, Wenliang
    Tian, Xiaolin
    Sun, Yankui
    MATERIALS RESEARCH AND APPLICATIONS, PTS 1-3, 2014, 875-877 : 1982 - +
  • [38] A dynamic wavelet filtering for anterior chamber optical coherence Tomographic images
    Du, Wen Liang
    Tian, Xiao Lin
    Sun, Yan Kui
    Advanced Materials Research, 2014, 875-877 : 1982 - 1988
  • [39] Photoreceptor impairment on optical coherence tomographic images in patients with retinitis pigmentosa
    Hagiwara, Akira
    Mitamura, Yoshinori
    Kumagai, Ken
    Baba, Takayuki
    Yamamoto, Shuichi
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (02) : 237 - U186
  • [40] Deep learning of fundus images and optical coherence tomography images for ocular disease detection – a review
    Rizvana M.
    Narayanan S.
    Multimedia Tools and Applications, 2024, 83 (41) : 88745 - 88789