A dosimetric comparison of two intensity modulated radiotherapy techniques: Tomotherapy versus dynamic linear accelerator

被引:0
|
作者
Whitelaw, G. [1 ]
Blasiak-Wal, I.
Cooke, K.
Usher, C. [1 ]
MacDougall, N. D.
Plowman, P. N. [2 ]
机构
[1] St Bartholomews Hosp, London, England
[2] St Bartholomews Hosp, Dept Radiotherapy, London, England
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
407
引用
收藏
页码:S182 / S182
页数:1
相关论文
共 50 条
  • [1] A dosimetric comparison between two intensity-modulated radiotherapy techniques:: tomotherapy vs dynamic linear accelerator
    Whitelaw, G. L.
    Blasiak-Wal, I.
    Cooke, K.
    Usher, C.
    Macdougall, N. D.
    Plowman, P. N.
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (964): : 333 - 340
  • [2] Dosimetric comparison of helical tomotherapy and intensity-modulated radiotherapy in cervical cancer
    Liu, J.
    Zhu, L.
    Li, S.
    Gao, S.
    Yan, J.
    Xie, L.
    Hou, Z.
    Zhou, X.
    Liu, B.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1005 - S1006
  • [3] A Dosimetric Comparison of Helical Tomotherapy Versus Intensity Modulated Proton for Lung Cancer
    Mo, X.
    Perumal, K.
    Mackie, R.
    MEDICAL PHYSICS, 2012, 39 (06) : 3836 - 3836
  • [4] Radiotherapy for Esophageal Cancer Using Simultaneous Integrated Boost Techniques: Dosimetric Comparison of Helical TomoTherapy, Volumetric-modulated Arc Therapy (RapidArc) and Dynamic Intensity-Modulated Radiotherapy
    Wang, Yao-Ching
    Chen, Shang-Wen
    Chien, Chun-Ru
    Hsieh, Te-Chun
    Yu, Chun-Yen
    Kuo, Yu-Cheng
    Yang, Shih-Neng
    Kao, Chia-Hung
    Liang, Ji-An
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (06) : 485 - 491
  • [5] Comparison of conformal radiotherapy, intensity-modulated radiotherapy and tomotherapy irradiation techniques in prostate cancers
    Tugrul, Taylan
    Olacak, Nezahat
    Koylu, Murat
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (03) : 276 - 279
  • [6] Dosimetric comparison of MLC leaf sequencing techniques for static and dynamic intensity modulated radiotherapy for nasopharyngeal carcinoma
    Kishore, RG
    Vellaiyan, S
    Chander, JR
    Tharmar, G
    Subhash, C
    Gopishankar, N
    Kumar, S
    Kumar, BA
    Rajvir, S
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S545 - S546
  • [7] Dosimetric comparison of intensity modulated radiotherapy techniques and standard wedged tangents for whole breast radiotherapy
    Fong, Andrew
    Bromley, Regina
    Beat, Mardi
    Vien, Din
    Dineley, Jude
    Morgan, Graeme
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2009, 53 (01) : 92 - 99
  • [8] Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
    Kinhikar, Rajesh Ashok
    Ghadi, Yogesh G.
    Sahoo, Priyadarshini
    Laskar, Sarbani Ghosh
    Deshpande, Deepak D.
    Shrivastava, Shyam K.
    Agarwal, Jaiprakash
    JOURNAL OF MEDICAL PHYSICS, 2015, 40 (04) : 190 - 197
  • [9] DOSIMETRIC COMPARISON OF FIELD IN FIELD INTENSITY MODULATED RADIOTHERAPY TECHNIQUE WITH CONFORMAL RADIOTHERAPY TECHNIQUES IN BREAST CANCER
    Ercan, T.
    Igdem, S.
    Alco, G.
    Zengin, F.
    Ozgules, R.
    Atilla, S.
    Dincer, M.
    Okkan, S.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S201 - S202
  • [10] Comparison of two different plan validation techniques for intensity modulated radiotherapy with dynamic multileaf collimator
    Selvaraj, RN
    Wu, A
    King, GC
    Moreland, R
    Lalonde, R
    Gerszten, K
    Varlotto, J
    Kalnicki, S
    MEDICAL PHYSICS, 2003, 30 (06) : 1500 - 1500