Hemolysis and cytotoxicity mechanisms of biodegradable magnesium and its alloys

被引:157
|
作者
Zhen, Zhen [1 ]
Liu, Xiaoli [2 ]
Huang, Tao [3 ]
Xi, TingFei [1 ,4 ,5 ]
Zheng, Yufeng [1 ,3 ,5 ]
机构
[1] Peking Univ, Ctr Biomed Mat & Tissue Engn, Acad Adv Interdisciplinary Studies, Beijing 100871, Peoples R China
[2] Univ Sci & Technol Beijing, Sch Mat Sci & Engn, Beijing 100083, Peoples R China
[3] Peking Univ, Coll Engn, Dept Mat Sci & Engn, State Key Lab Turbulence & Complex Syst, Beijing 100871, Peoples R China
[4] Peking Univ, Shenzhen Inst, Biomed Engn Res Ctr, Shenzhen 518057, Peoples R China
[5] Peking Univ, Shenzhen Inst, Shenzhen Key Lab Human Tissue Regenerat & Repair, Shenzhen 518057, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
Biodegradable magnesium; 1929; cells; Hemolysis ratio; Magnesium ion concentration; pH values; CAPACITATIVE CA2+ ENTRY; IN-VITRO CORROSION; EXTRACELLULAR MG2+; PH; STENTS; PERFORMANCE; METAL; IMPLANTATION; DEGRADATION; BEHAVIOR;
D O I
10.1016/j.msec.2014.08.038
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Good hemocompatibility and cell compatibility are essential requirements for coronary stents, especially-for biodegradable magnesium alloy stents, which could change the in situ environment after implanted. In this work, the effects of magnesium ion concentration and pH value on the hemolysis and cytotoxicity have been evaluated. Solution with different Mg2+ concentration gradients and pH values of normal saline and cell culture media DMEM adjusted by MgCl2 and NaOH respectively were tested for the hemolysis and cell viability. Results show that even when the concentration of Mg2+ reaches 1000 mu g/mL, it has little destructive effect on erythrocyte, and the high pH value over 11 caused by the degradation is the real reason for the high hemolysis ratio. Low concentrations of Mg2+ (<100 mu g/mL) cause no cytotoxicity to L929 cells, of which the cell viability is above 80%, Mg2+ (>300 high concentrations of m(>300 mu g/mL) could induce obvious death of the L929 cells. The pH of the extract plays a synergetic effect on cytotoxicity, due to the buffer action of the cell culture medium. To validate this conclusion, commercial pure Mg using normal saline and PBS as extract was tested with the measurement of pH and Mg2+ concentration. Pure Mg leads to a higher hemolysis ratio in normal saline (47.76%) than in buffered solution (4.38%) with different pH values and low concentration of Mg2+. The Mg extract culture media caused no cytotoxicity, with pH = 8.44 and 47.80 mu g/mL Mg2+. It is suggested that buffered solution and dynamic condition should be adopted in the hemolysis evaluation. (C) 2014 Published by Elsevier B.V.
引用
收藏
页码:202 / 206
页数:5
相关论文
共 50 条
  • [21] Nondestructive Evaluation of Biodegradable Magnesium Alloys
    Faktorova, Dagmar
    Novy, Frantisek
    Steigmann, Rozina
    Istrate, Bogdan
    Munteanu, Corneliu
    Savin, Adriana
    13TH INTERNATIONAL CONFERENCE ON ELEKTRO (ELEKTRO 2020), 2020,
  • [22] A review on magnesium alloys as biodegradable materials
    Gu X.-N.
    Zheng Y.-F.
    Frontiers of Materials Science in China, 2010, 4 (2): : 111 - 115
  • [23] Surface modification (o)f biodegradable magnesium and its alloys for biomedical applications
    Tian, Peng
    Liu, Xuanyong
    REGENERATIVE BIOMATERIALS, 2015, 2 (02) : 135 - 151
  • [24] Plastic deformation micro-mechanisms in magnesium and its alloys
    Wu, J.
    Si, S.
    Ghori, U.
    Chiu, Y. L.
    ADVANCES IN ENGINEERING MATERIALS, STRUCTURES AND SYSTEMS: INNOVATIONS, MECHANICS AND APPLICATIONS, 2019, : 379 - 382
  • [25] Research progress on surface modification of biodegradable magnesium and magnesium alloys
    Hu, Yi-Juan
    Bi, Yan-Ze
    He, Dong-Lei
    Yu, Hong-Yan
    Li, Yan
    Surface Technology, 2019, 48 (09): : 11 - 19
  • [26] Biodegradable Magnesium Alloys for Personalised Temporary Implants
    Hendea, Radu Emil
    Raducanu, Doina
    Claver, Adrian
    Garcia, Jose Antonio
    Cojocaru, Vasile Danut
    Nocivin, Anna
    Stanciu, Doina
    Serban, Nicolae
    Ivanescu, Steliana
    Trisca-Rusu, Corneliu
    Campian, Radu Septimiu
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2023, 14 (08)
  • [27] Surface design of biodegradable magnesium alloys - A review
    Wu, Guosong
    Ibrahim, Jamesh Mohammed
    Chu, Paul K.
    SURFACE & COATINGS TECHNOLOGY, 2013, 233 : 2 - 12
  • [28] Review on magnesium alloys as biodegradable implant materials
    Gill, Puneet
    Munroe, Norman
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 10 (04) : 383 - 398
  • [29] METAL OXIDE COATING ON BIODEGRADABLE MAGNESIUM ALLOYS
    Pesode, Pralhad
    Barve, Shivprakash
    Wankhede, Sagar, V
    Chipade, Amar
    3C EMPRESA, 2023, 12 (01): : 392 - 421
  • [30] Progress in Research on Biodegradable Magnesium Alloys: A Review
    Li, Huan
    Wen, Jiuba
    Liu, Ya
    He, Junguang
    Shi, Huina
    Tian, Peiwu
    ADVANCED ENGINEERING MATERIALS, 2020, 22 (07)