Luminal enhancement in intracranial aneurysms: fact or feature?-A quantitative multimodal flow analysis

被引:7
|
作者
Gaidzik, Franziska [1 ]
Pravdivtseva, Mariya [2 ,3 ]
Larsen, Naomi [3 ]
Jansen, Olav [3 ]
Hoevener, Jan-Bernd [2 ,3 ]
Berg, Philipp [1 ]
机构
[1] Univ Magdeburg, Otto von Guericke Univ, Lab Fluid Dynam & Tech Flows, Forschungscampus STIMULATE, Univ Pl 3, D-39106 Magdeburg, Germany
[2] Univ Kiel, Mol Imaging North Competence Ctr MOIN CC, Sect Biomed Imaging, Kiel, Germany
[3] Univ Med Ctr Schleswig Holstein UKSH, Dept Radiol & Neuroradiol, Kiel, Germany
关键词
Intracranial aneurysms; Luminal enhancement; VW-MRI; Computational fluid dynamics; Phase-contrast-MRI; WALL; HEMODYNAMICS; MORPHOLOGY; RUPTURE;
D O I
10.1007/s11548-021-02486-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose Intracranial aneurysm (IA) wall enhancement on post-contrast vessel wall magnetic resonance imaging (VW-MRI) is assumed to be a biomarker for vessel wall inflammation and aneurysm instability. However, the exact factors contributing to enhancement are not yet clarified. This study investigates the relationship between luminal enhancement and intra-aneurysmal flow behaviour to assess the suitability of VW-MRI as a surrogate method for determining quantitative and qualitative flow behaviour in the aneurysm sac. Methods VW-MRI signal is measured in the lumen of three patient-specific IA flow models and compared with the intra-aneurysmal flow fields obtained using phase-contrast magnetic resonance imaging (PC-MRI) and computational fluid dynamics (CFD). The IA flow models were supplied with two different time-varying flow regimes. Results Overall, the velocity fields acquired using PC-MRI or CFD were in good agreement with the VW-MRI enhancement patterns. Generally, the regions with slow-flowing blood show higher VW-MRI signal intensities, whereas high flow leads to a suppression of the signal. For all aneurysm models, a signal value above three was associated with velocity values below three cm/s. Conclusion Regions with lower enhancements have been correlated with the slow and high flow at the same time. Thus, further factors like flow complexity and stability can contribute to flow suppression in addition to the flow magnitude. Nevertheless, VW-MRI can qualitatively assess intra-aneurysmal flow phenomena and estimate the velocity range present in the corresponding region.
引用
收藏
页码:1999 / 2008
页数:10
相关论文
共 50 条
  • [21] Flow diverter retreatment for intracranial aneurysms: A meta-analysis of efficacy and feasibility
    Lee, Irene
    Kao, Yung-Shuo
    Lai, Yen-Jun
    Yen, Ho-Hsian
    INTERVENTIONAL NEURORADIOLOGY, 2024, 30 (01) : 37 - 42
  • [22] SILK flow diverter for treatment of intracranial aneurysms: initial experience and cost analysis
    Shankar, Jai Jai Shiva
    Vandorpe, Robert
    Pickett, Gwynedd
    Maloney, William
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 : III11 - III15
  • [23] Quantitative Analysis of The Blood Flow Reduction In Brain Aneurysms Treated By Flow Diverter Stents
    Chien, Aichi
    Yu, Qianyi
    Zosso, Dominique
    STROKE, 2015, 46
  • [24] A systematic review and meta-analysis of Surpass flow diverter for the treatment of intracranial aneurysms
    William A. Florez-Perdomo
    Tariq Janjua
    Luis Rafael Moscote-Salazar
    Adesh Shrivastava
    Sumit Raj
    Amit Agrawal
    Egyptian Journal of Neurosurgery, 38
  • [25] Early Versus Delayed Flow Diversion for Ruptured Intracranial Aneurysms: A Meta-Analysis
    Dossani, Rimal Hanif
    Patra, Devi P.
    Kosty, Jennifer
    Jumah, Fareed
    Kuybu, Okkes
    Mohammed, Nasser
    Waqas, Muhammad
    Riaz, Muhammad
    Cuellar, Hugo
    WORLD NEUROSURGERY, 2019, 126 : 41 - 52
  • [26] Flow diversion for the treatment of intracranial bifurcation aneurysms: a systematic review and meta-analysis
    Kashkoush, Ahmed
    El-Abtah, Mohamed Ehab
    Petitt, Jordan C.
    Glauser, Gregory
    Winkelman, Robert
    Achey, Rebecca L.
    Davison, Mark
    Abdulrazzak, Mohammad A.
    Hussain, Shazam M.
    Toth, Gabor
    Bain, Mark
    Moore, Nina
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2024, 16 (09)
  • [27] Flow-Diverter Devices for Intracranial Aneurysms: Systematic Review and Meta-analysis
    Arrese, Ignacio
    Sarabia, Rosario
    Pintado, Rebeca
    Delgado-Rodriguez, Miguel
    NEUROSURGERY, 2013, 73 (02) : 193 - 199
  • [28] A systematic review and meta-analysis of Surpass flow diverter for the treatment of intracranial aneurysms
    Florez-Perdomo, William A.
    Janjua, Tariq
    Moscote-Salazar, Luis Rafael
    Shrivastava, Adesh
    Raj, Sumit
    Agrawal, Amit
    EGYPTIAN JOURNAL OF NEUROSURGERY, 2023, 38 (01)
  • [29] Computational Hemodynamics Analysis of Intracranial Aneurysms Treated with Flow Diverters: Correlation with Clinical Outcomes
    Chong, W.
    Zhang, Y.
    Qian, Y.
    Lai, L.
    Parker, G.
    Mitchell, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (01) : 136 - 142
  • [30] Computational fluid dynamics analysis of intracranial aneurysms treated with flow diverters: A case report
    Zhang, H.
    Li, L.
    Miao, F.
    Yu, J.
    Zhou, B.
    Pan, Y.
    NEUROCHIRURGIE, 2022, 68 (02) : 235 - 238