THERMAL ANALYSIS OF A MODULAR, MICROFLUIDIC DEVICE FOR THE RAPID DETECTION OF STROKE

被引:0
|
作者
Lowrey, Brooks B. [1 ]
Park, Daniel S. [1 ,2 ]
Murphy, Michael C. [1 ,2 ]
机构
[1] Louisiana State Univ, Dept Mech Engn, Baton Rouge, LA 70803 USA
[2] Louisiana State Univ, Ctr Biomodular Multiscale Syst, Baton Rouge, LA 70803 USA
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A modular, microfluidic device was designed to aid in the rapid detection and treatment of stroke. The device modules process whole blood for the detection of genes expressed in response to a stroke event using a series of assay steps including: cell capture using antibodies, thermal lysis, solid-phase reversible immobilization (SPRI) of nucleic acids, reverse transcription (RT), ligase detection reaction (LDR), and single pair fluorescence resonance energy transfer (spFRET) readout. Cell lysis, RI, and LDR require temperatures of 90 degrees C, 37 degrees C, 65 degrees C and 95 degrees C respectively, therefore strict thermal isolation constraints between thermal zones in the device modules were necessary. Thermal isolation was accomplished using 2 mm and 1 mm air gaps between the fluidic modules and heating elements in the polymer device. Finite element mathematical models (ANSYS v. 12.1, Houston, PA) were used to characterize the thermal zones in two 2D simulations. Section 1 simulation results showed +/- 1.5 degrees C in cell lysis, +/- 1.6 degrees C in RT, and +/- 1.6 degrees C in the denaturation section of LDR. Section 2 simulation showed +/- 2.6 degrees C in denaturation and +/- 0.4 degrees C in the annealing/extension zone of LDR.
引用
收藏
页码:93 / 95
页数:3
相关论文
共 50 条
  • [31] A modular, reversible sealing, and reusable microfluidic device for drug screening
    Vit, Franciele Flores
    Nunes, Rony
    Wu, Yu Tzu
    Soares, Marco Cesar Prado
    Godoi, Naiara
    Fujiwara, Eric
    Carvalho, Hernandes F.
    de la Torre, Lucimara Gaziola
    ANALYTICA CHIMICA ACTA, 2021, 1185
  • [32] Single-pipetting microfluidic assay device for rapid detection of Salmonella from poultry package
    Fronczek, Christopher F.
    You, David J.
    Yoon, Jeong-Yeol
    BIOSENSORS & BIOELECTRONICS, 2013, 40 (01): : 342 - 349
  • [33] A disposable and cost efficient microfluidic device for the rapid chip-based electrical detection of DNA
    Schueler, Thomas
    Kretschmer, Robert
    Jessing, Sven
    Urban, Matthias
    Fritzsche, Wolfgang
    Moeller, Robert
    Popp, Juergen
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (01): : 15 - 21
  • [34] Development of a rapid phenotypic test on a microfluidic device for carbapenemase detection using the chromogenic compound nitrocefin
    Allen, Collette
    Turner, Carrie
    Kalsi, Sumit
    Jamieson, David
    Li, Yuetao
    Morgan, Hywel
    Sutton, J. Mark
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2020, 96 (04)
  • [35] Rapid detection of Mycoplasma pneumonia in a microfluidic device using immunoagglutination assay and static light scattering
    Kim, Keesung
    Jung, Ho-Sup
    Song, Jae-Young
    Lee, Man-Ryul
    Kim, Kye-Seong
    Suh, Kahp-Yang
    ELECTROPHORESIS, 2009, 30 (18) : 3206 - 3211
  • [36] Thermal conductivity measurement of liquids in a microfluidic device
    D. Kuvshinov
    M. R. Bown
    J. M. MacInnes
    R. W. K. Allen
    R. Ge
    L. Aldous
    C. Hardacre
    N. Doy
    M. I. Newton
    G. McHale
    Microfluidics and Nanofluidics, 2011, 10 : 123 - 132
  • [37] Thermal conductivity measurement of liquids in a microfluidic device
    Kuvshinov, D.
    Bown, M. R.
    MacInnes, J. M.
    Allen, R. W. K.
    Ge, R.
    Aldous, L.
    Hardacre, C.
    Doy, N.
    Newton, M. I.
    McHale, G.
    MICROFLUIDICS AND NANOFLUIDICS, 2011, 10 (01) : 123 - 132
  • [38] An integrated microfluidic device for rapid and high-sensitivity analysis of circulating tumor cells
    Jiang, Jianing
    Zhao, Hui
    Shu, Weiliang
    Tian, Jing
    Huang, Yuqing
    Song, Yongxin
    Wang, Ruoyu
    Li, Encheng
    Slamon, Dennis
    Hou, Dongmei
    Du, Xiaohui
    Zhang, Lichuan
    Chen, Yan
    Wang, Qi
    SCIENTIFIC REPORTS, 2017, 7
  • [39] Microfluidic filter device coupled mass spectrometry for rapid bacterial antimicrobial resistance analysis
    Zhang, Dongxue
    Zhang, Yijie
    Yin, Fan
    Qin, Qin
    Bi, Hongyan
    Liu, Baohong
    Qiao, Liang
    ANALYST, 2021, 146 (02) : 515 - 520
  • [40] An integrated microfluidic device for rapid and high-sensitivity analysis of circulating tumor cells
    Jianing Jiang
    Hui Zhao
    Weiliang Shu
    Jing Tian
    Yuqing Huang
    Yongxin Song
    Ruoyu Wang
    Encheng Li
    Dennis Slamon
    Dongmei Hou
    Xiaohui Du
    Lichuan Zhang
    Yan Chen
    Qi Wang
    Scientific Reports, 7