Embedded Quantitative MRI T1ρ Mapping Using Non-Linear Primal-Dual Proximal Splitting

被引:2
|
作者
Hanhela, Matti [1 ]
Paajanen, Antti [1 ]
Nissi, Mikko J. [1 ]
Kolehmainen, Ville [1 ]
机构
[1] Univ Eastern Finland, Dept Appl Phys, Kuopio 70211, Finland
基金
芬兰科学院;
关键词
compressed sensing; embedded reconstruction; model-based reconstruction; quantitative MRI; T1rho mapping; MAGNETIC-RESONANCE; CEREBRAL-ISCHEMIA; CARTILAGE; RECONSTRUCTION; DISPERSION; FIBROSIS; TIME;
D O I
10.3390/jimaging8060157
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Quantitative MRI (qMRI) methods allow reducing the subjectivity of clinical MRI by providing numerical values on which diagnostic assessment or predictions of tissue properties can be based. However, qMRI measurements typically take more time than anatomical imaging due to requiring multiple measurements with varying contrasts for, e.g., relaxation time mapping. To reduce the scanning time, undersampled data may be combined with compressed sensing (CS) reconstruction techniques. Typical CS reconstructions first reconstruct a complex-valued set of images corresponding to the varying contrasts, followed by a non-linear signal model fit to obtain the parameter maps. We propose a direct, embedded reconstruction method for T-1 rho mapping. The proposed method capitalizes on a known signal model to directly reconstruct the desired parameter map using a non-linear optimization model. The proposed reconstruction method also allows directly regularizing the parameter map of interest and greatly reduces the number of unknowns in the reconstruction, which are key factors in the performance of the reconstruction method. We test the proposed model using simulated radially sampled data from a 2D phantom and 2D cartesian ex vivo measurements of a mouse kidney specimen. We compare the embedded reconstruction model to two CS reconstruction models and in the cartesian test case also the direct inverse fast Fourier transform. The T-1 rho RMSE of the embedded reconstructions was reduced by 37-76% compared to the CS reconstructions when using undersampled simulated data with the reduction growing with larger acceleration factors. The proposed, embedded model outperformed the reference methods on the experimental test case as well, especially providing robustness with higher acceleration factors.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Primal-dual block-proximal splitting for a class of non-convex problems
    Mazurenko S.
    Jauhiainen J.
    Valkonen T.
    1600, Kent State University (52): : 509 - 552
  • [2] PRIMAL-DUAL BLOCK-PROXIMAL SPLITTING FOR A CLASS OF NON-CONVEX PROBLEMS
    Mazurenko, Stanislav
    Jauhiainen, Jyrki
    Valkonen, Tuomo
    ELECTRONIC TRANSACTIONS ON NUMERICAL ANALYSIS, 2020, 52 : 509 - 552
  • [3] Primal-Dual Proximal Splitting and Generalized Conjugation in Non-smooth Non-convex Optimization
    Clason, Christian
    Mazurenko, Stanislav
    Valkonen, Tuomo
    APPLIED MATHEMATICS AND OPTIMIZATION, 2021, 84 (02): : 1239 - 1284
  • [4] A primal-dual active set strategy for non-linear multibody contact problems
    Hüeber, S
    Wohlmuth, BI
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2005, 194 (27-29) : 3147 - 3166
  • [5] Lagrange multipliers and the primal-dual method in the non-linear static equilibrium of multibody systems
    Aviles, R
    Ajuria, G
    Bilbao, A
    Vallejo, J
    COMMUNICATIONS IN NUMERICAL METHODS IN ENGINEERING, 1998, 14 (05): : 463 - 472
  • [6] COUPLED PRIMAL-DUAL SYMMETRIC FORMULATION AND ADDED MASS CONCEPT IN NON-LINEAR ELASTODYNAMICS
    VALID, R
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE II, 1988, 306 (03): : 165 - 168
  • [7] Solving non-linear portfolio optimization problems with the primal-dual interior point method
    Gondzio, Jacek
    Grothey, Andreas
    EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2007, 181 (03) : 1019 - 1029
  • [8] SYMMETRIC PRIMAL-DUAL FORMULATION AND ADDED MASS FOR NON-LINEAR FLUID-STRUCTURE INTERACTIONS
    VALID, R
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE II, 1988, 307 (08): : 879 - 882
  • [9] Unilateral non-linear dynamic contact of thin-walled structures using a primal-dual active set strategy
    Hartmann, S.
    Brunssen, S.
    Ramm, E.
    Wohlmuth, B.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2007, 70 (08) : 883 - 912
  • [10] Quantitative T1 mapping and absolute water content measurement using MRI
    Neeb, H
    Dierkes, T
    Shah, NJ
    QUANTITATION IN BIOMEDICAL IMAGING WITH PET AND MRI, 2004, (1265): : 113 - 123