Screening nitrate in forages with a test strip: Collaborative study

被引:0
|
作者
Jain, AV [1 ]
Ross, PF
Carlson, MP
机构
[1] Univ Georgia, Coll Vet Med, Athens Vet Diagnost Lab, Athens, GA 30602 USA
[2] USDA, Natl Vet Serv Labs, Toxicol Sect, Ames, IA 50010 USA
[3] Univ Nebraska, Vet Diagnost Ctr, Lincoln, NE 68583 USA
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A collaborative study was conducted for screening nitrate in forages with a commercially available test strip, The method involves extracting a finely ground sample with deionized water. The test strip is dipped in the sample extract. The color of the reaction zone on the test strip changes from white to pink or purple depending on the nitrate concentration in sample extract. The nitrate present in the extract is determined by comparing the color of the test strip to the color scale on the test strip container. Six blind quintuplicates of forage samples were analyzed by 20 collaborators. Nitrate concentrations in forage samples tested ranged from <1000 ppm nitrate to >10 000 ppm nitrate on dry matter basis. Each collaborator was asked to assign each sample to one of the 4 following nitrate concentration ranges: (1) <1000 ppm, (2) 1000 to 5000 ppm, (3) >5000 ppm to 10 000 ppm, and (4) >10 000 ppm. Nineteen of 20 collaborators reported results. Results from 2 laboratories were rejected as outliers by inspection and chi(2) test, Sensitivity rates (p(+)) ranged from 0.965 to 0.998, with standard errors of 0.006 to 0.16. Specificity rates (p(-)) ranged from 0.991 to 0.997 for the 4 ranges, with standard errors of 0.003 to 0.006, False-positive rates (pf(+)) ranged from 0.006 to 0.046, with standard errors of 0.006 to 0.025, False-negative rates (pf(-)) ranged from 0.003 to 0.007, with standard errors of 0.003 to 0.006, Screening nitrate in forages with a test strip has been adopted first action by AOAC INTERNATIONAL.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 50 条
  • [42] Surface carrier test as a quantitative test of disinfection: A collaborative study
    Hamilton, MA
    DeVries, TA
    Rubino, JR
    JOURNAL OF AOAC INTERNATIONAL, 1995, 78 (04) : 1102 - 1109
  • [43] Accuracy of Leukocyte Esterase Reagent Strip (LERS) test for rapid bedside screening of spontaneous bacterial peritonitis: An observational study
    Khairnar, Harshad
    Ingle, Meghraj
    Pandey, Vikas
    Kolhe, Kailash
    Chauhan, Shamsher
    Sawant, Prabha
    Walke, Swapnil
    Chaudhary, Vipul
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2020, 9 (11) : 5542 - 5546
  • [44] RABBIT EYE IRRITATION TEST - COLLABORATIVE STUDY
    MARZULLI, FN
    RUGGLES, DI
    JOURNAL OF THE ASSOCIATION OF OFFICIAL ANALYTICAL CHEMISTS, 1973, 56 (04): : 905 - 914
  • [45] A COLLABORATIVE STUDY OF A STANDARDIZED AMES TEST PROTOCOL
    ADAMS, N
    CLAXTON, L
    HUGHES, T
    MYERS, L
    ENVIRONMENTAL MUTAGENESIS, 1985, 7 : 45 - 45
  • [46] Colorimetric test strip cassette readout with a smartphone for on-site and rapid screening test of carbamate pesticides in vegetables
    Rakkhun, Waraporn
    Jantra, Jongjit
    Cheubong, Chehasan
    Teepoo, Siriwan
    MICROCHEMICAL JOURNAL, 2022, 181
  • [47] Urinary albumin strip assay as a screening test to replace quantitative technology in certain conditions
    Salinas, Maria
    Lopez-Garrigos, Maite
    Flores, Emilio
    Lugo, Javier
    Leiva-Salinas, Carlos
    Massa-Dominguez, Beatriz
    Gomez-Gras, Antonio
    Iranzo, Norma
    Canals-Baeza, Alejandro
    Lopez-Blasco, Jose L.
    Gonzalez-Alvaro, Esperanza
    Frances, Ramon de Juan
    Gisbert-Segura, Jordi
    Oliver-Ros, Rosario
    Asencio-Aznar, Alberto
    Ballester-Baixauli, Juan J.
    Pardo-Tomas, Carmen
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2019, 57 (02) : 204 - 209
  • [48] A dip-and-read test strip for the determination of nitrite in food samples for the field screening
    Fang, YJ
    Gao, ZX
    Yan, SL
    Wang, HY
    Zhou, HY
    ANALYTICAL LETTERS, 2005, 38 (11) : 1803 - 1811
  • [49] PAPER STRIP SCREENING METHOD FOR DETECTION OF CYANIDE IN BLOOD USING CYANTESMO TEST PAPER
    FLIGNER, CL
    LUTHI, R
    LINKAITYTEWEISS, E
    RAISYS, VA
    AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 1992, 13 (01): : 81 - 84
  • [50] STUDY ON STRIP EDGING .4. ON LINE TEST OF STRIP EDGER BETWEEN FINISHING STANDS
    TAZOE, N
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 : 1141 - 1141