Rapid detection of common viruses using multi-analyte suspension arrays

被引:15
|
作者
Yu, Daojun [1 ,2 ]
Wu, Shenghai [2 ]
Wang, Baohong [1 ]
Chen, Yunbo [1 ]
Li, Lanjuan [1 ]
机构
[1] Zhejiang Univ, Sch Med, Affiliated Hosp 1, State Key Lab Diag & Treatment Infect Dis, Hangzhou 310003, Zhejiang, Peoples R China
[2] Hangzhou First Peoples Hosp, Dept Clin Labs, Hangzhou 310006, Zhejiang, Peoples R China
关键词
Multi-analyte suspension arrays; Herpes virus (HSV); Human papilloma virus (HPV); Hepatitis B virus (HBV); Symmetric PCR; Asymmetric PCR; MICROARRAY; ASSAY; PCR;
D O I
10.1016/j.jviromet.2011.06.017
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method that uses specific oligonucleotide probes coupled to a specific array of fluorescent microspheres in multi-analyte suspension arrays was employed for the detection of common viruses, such as Herpes virus (HSV), Human papillomavirus (HPV) and Hepatitis B virus (HBV). Sixteen species-specific probes and 9 sets of specific primers were designed based on conserved sequences of these viruses in the GenBank database. Serial symmetric PCR, asymmetric PCR and multiple PCR assays were employed to evaluate the sensitivity, specificity and reproducibility of multi-analyte suspension arrays analyzed on a Luminex-100 analyzer instrument. The symmetric PCR amplification of four types of HSV, four types of HPV and HBV genotypes of B, C and D, combined with their corresponding species-specific probes and specificities were completely concordant with the results from a comparative sequence analyses. There was no significant difference in the median fluorescence intensity (MFI) value between symmetric PCR and asymmetric PCR when the viral DNA concentration was above 10(4) copies/test. Both PCR products were negative in the multi-analyte suspension arrays with viral DNA concentrations less than 10(3) copies/test. A multi-analyte suspension array is a flexible, high-throughput, relatively simple method for rapid identification of common viruses in the clinical laboratory. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 70
页数:7
相关论文
共 50 条
  • [31] A MULTI-ANALYTE BLOOD TEST FOR ACCURATE AND EARLY DETECTION OF HEPATOCELLULAR CARCINOMA
    Lin, Nan
    Lin, Yongping
    Xu, Jianfeng
    Li, Mingzhen
    Liu, Dan
    Gallant, Max A.
    Kubota, Naoto
    Roy, Dhruvajyoti
    Li, Jason
    Gorospe, Emmanuel Cruz
    Sherman, Morris
    Gish, Robert G.
    Abou-Alfa, Ghassan K.
    Nguyen, Mindie H.
    Taggart, David J.
    Van Etten, Richard A.
    Hoshida, Yujin
    Li, Wei
    HEPATOLOGY, 2021, 74 (06) : 1418A - 1418A
  • [32] Study on gene markers of thrombosis in coronary heart disease by multi-analyte suspension array technology
    He, W.
    Hu, Y.
    Yu, J.
    Guo, T.
    Zhang, X.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 85 - 85
  • [33] Polarization Selective PCF-Based Plasmonic Biosensor for Multi-Analyte Detection
    Azman, Mohd Fahmi
    Mashrafi, Md.
    Haider, Firoz
    Ahmed, Rajib
    Aoni, Rifat Ahmmed
    Junayed, Md
    Ru, Wong Wei
    Mahdiraji, Ghafour Amouzad
    Adikan, Faisal Rafiq Mahamd
    PLASMONICS, 2024, 19 (06) : 2847 - 2856
  • [34] Chronoamperometric Detection of Heavy Metal Ions for Multi-analyte Water Analysis with Microsensors
    Uka, Besnik
    Kieninger, Jochen
    Rupitsch, Stefan J.
    Urban, Gerald A.
    Weltin, Andreas
    2022 IEEE SENSORS, 2022,
  • [35] A multi-analyte selective dansyl derivative for the fluorescence detection of Cu(ii) and cysteine
    Anand Thangaraj
    Vinita Bhardwaj
    Suban K. Sahoo
    Photochemical & Photobiological Sciences, 2019, 18 : 1533 - 1539
  • [36] Multi-analyte analysis system using an antibody-based biochip
    Maria Moreno-Bondi
    Jean Alarie
    Tuan Vo-Dinh
    Analytical and Bioanalytical Chemistry, 2003, 375 : 120 - 124
  • [37] Automated fluidic system with a chaotic microfluidic reaction chamber for rapid, multi-analyte immunosensing
    Kai, Junhai
    Zoo, Zhiwei
    Han, Jungyoup
    Lee, Soo-Hyun
    Hong, Bin
    Ren, Yongjie
    Kang, Kyung A.
    Ahn, Chong H.
    TRANSDUCERS '07 & EUROSENSORS XXI, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007,
  • [38] Development and clinical evaluation of an automated multi-analyte biochip array for rapid stroke diagnosis
    Harte, E.
    CLINICA CHIMICA ACTA, 2019, 493
  • [39] A multi-analyte selective dansyl derivative for the fluorescence detection of Cu(ii) and cysteine
    Thangaraj, Anand
    Bhardwaj, Vinita
    Sahoo, Suban K.
    PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2019, 18 (06) : 1533 - 1539
  • [40] Detection and Quantification of Multi-Analyte Mixtures Using a Single Sensor and Multi-Stage Data-Weighted RLSE
    Sothivelr, Karthick
    Bender, Florian
    Josse, Fabien
    Yaz, Edwin E.
    Ricco, Antonio J.
    2018 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (IFCS), 2018, : 48 - 49