TOF-SIMS with Argon Gas Cluster Ion Beams: A Comparison with C60+

被引:170
|
作者
Rabbani, Sadia [1 ]
Barber, Andrew M. [2 ]
Fletcher, John S. [1 ]
Lockyer, Nicholas P. [1 ]
Vickerman, John C. [1 ]
机构
[1] Univ Manchester, Sch Chem Engn & Analyt Sci, Manchester Interdisciplinary Bioctr, Manchester M13 9PL, Lancs, England
[2] Ionoptika Ltd, Southampton, Hants, England
基金
英国工程与自然科学研究理事会;
关键词
MASS-SPECTROMETRY; THIN-FILMS; SURFACES; YIELD; BOMBARDMENT; EMISSION; LAYERS; MODEL;
D O I
10.1021/ac200288v
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Time-of-flight secondary ion mass spectrometry (TOF-SIMS) is an established technique for the characterization of solid sample surfaces. The introduction of polyatomic ion beams, such as C-60, has provided the associated ability to perform molecular depth-profiling and 3D molecular imaging. However, not all samples perform equally under C-60 bombardment, and it is probably naive to think that there will be an ion beam that will be applicable in all situations. It is therefore important to explore the potential of other candidates. A systematic study of the suitability of argon gas cluster ion beams (Ar-GCIBs) of general composition Ar-n(+), where n = 60-3000, as primary particles in TOP-SIMS analysis has been performed. We have assessed the potential of the Ar-GCIBs for molecular depth-profiling in terms of damage accumulation and sputter rate and also as analysis beams where spectral quality and secondary ion yields are considered. We present results with direct comparison with C-60 ions on the same sample in the same instrument on polymer, polymer additive, and biomolecular samples, including lipids and small peptides. Large argon clusters show reduced damage accumulation compared with C-60 with an approximately constant sputter rate as a function of Ar cluster size. Further, on some samples, large argon clusters produce changes in the mass spectra indicative of a more gentle ejection mechanism. However, there also appears to be a reduction in the ionization of secondary species as the size of the Ar cluster increases.
引用
收藏
页码:3793 / 3800
页数:8
相关论文
共 50 条
  • [31] ToF-SIMS analysis of a fluorocarbon-grafted PET with a gold cluster ion source
    Zhu, Zhengmao
    Kelley, Michael J.
    APPLIED SURFACE SCIENCE, 2006, 252 (19) : 6619 - 6623
  • [32] Stretching the limits of static SIMS with C60+
    Delcorte, A.
    Poleunis, C.
    Bertrand, P.
    APPLIED SURFACE SCIENCE, 2006, 252 (19) : 6494 - 6497
  • [33] Polymerization of solid C60 under C60+ cluster ion bombardment
    Lavrentiev, Vasily
    Vacik, Jiri
    Naramoto, Hiroshi
    Narumi, Kazumasa
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2009, 95 (03): : 867 - 873
  • [34] The use of argon cluster bombardment for the surface preparation of paint cross-sections for analysis by ToF-SIMS
    Vermeulen, M.
    Poleunis, C.
    Delcorte, A.
    Bertrand, P.
    Sanyova, J.
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 (10-11) : 781 - 785
  • [35] Polymerization of solid C60 under C60+ cluster ion bombardment
    Vasily Lavrentiev
    Jiri Vacik
    Hiroshi Naramoto
    Kazumasa Narumi
    Applied Physics A, 2009, 95
  • [36] Ion extraction from insulating fibers in ToF-SIMS
    Avci, R
    Hagenston, AM
    Equall, NL
    Groenewold, GS
    Gresham, GL
    Dahl, DA
    SURFACE AND INTERFACE ANALYSIS, 1999, 27 (08) : 789 - 796
  • [37] TOF-SIMS analysis of ion-water interactions
    Souda, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 232 : 125 - 133
  • [38] Optimizing C60 incidence angle for polymer depth profiling by ToF-SIMS
    Iida, Shin-ichi
    Miyayama, Takuya
    Sanada, Noriaki
    Suzuki, Mineharu
    Fisher, Gregory L.
    Bryan, Scott R.
    SURFACE AND INTERFACE ANALYSIS, 2011, 43 (1-2) : 214 - 216
  • [39] C60 sputtering of organics: A study using TOF-SIMS, XPS and nanoindentation
    Fisher, Gregory L.
    Dickinson, Michelle
    Bryan, Scott R.
    Moulder, John
    APPLIED SURFACE SCIENCE, 2008, 255 (04) : 819 - 823
  • [40] Cluster TOF-SIMS imaging:: A new light for in situ metabolomics?
    Mas, Sebastian
    Perez, Raul
    Martinez-Pinna, Roxana
    Egido, Jesus
    Vivanco, Fernando
    PROTEOMICS, 2008, 8 (18) : 3735 - 3745