Amperometric glucose biosensor based on platinum nanoparticle encapsulated with a clay

被引:21
|
作者
Han, Xiao [1 ]
Zhu, Yihua [1 ]
Yang, Xiaoling [1 ]
Li, Chunzhong [1 ]
机构
[1] E China Univ Sci & Technol, Key Lab Ultrafine Mat, Minist Educ, Sch Mat Sci & Engn, Shanghai 200237, Peoples R China
基金
中国国家自然科学基金;
关键词
Clay; Dendrimer; Pt nanoparticles; Glucose; Biosensor; DIRECT ELECTRON-TRANSFER; DIRECT ELECTROCHEMISTRY; CARBON-NANOTUBES; HEMOGLOBIN; CATALYSIS; OXIDASE; ELECTROCATALYSIS; FILMS;
D O I
10.1007/s00604-010-0424-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A hybrid system was constructed in neutral aqueous solution that consisted of clay clusters incorporated with platinum nanoparticles that were encapsulated with a poly(amidoamine) dendrimer through electrostatic interaction. Glucose oxidase was immobilized in this hybrid and used to modify a glassy carbon electrode so to obtain an enzymatic glucose biosensor. The nanohybrid material and the sensor were characterized by cyclic voltammetry and amperometry. The sensor has a response time of <3 s and a dynamic range from 0.01 to 16 mM. The detection limit is 4 mu M at a signal-to-noise ratio of 3.
引用
收藏
页码:233 / 239
页数:7
相关论文
共 50 条
  • [11] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the platinum electrode modified with NiO doped ZnO nanorods
    Chu, Xiangfeng
    Zhu, Xiaohua
    Dong, Yongping
    Chen, Tongyun
    Ye, Mingfu
    Sun, Wenqi
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 676 : 20 - 26
  • [12] Amperometric glucose biosensor based on electroconductive hydrogels
    Kotanen, Christian N.
    Tlili, Chaker
    Guiseppi-Elie, Anthony
    TALANTA, 2013, 103 : 228 - 235
  • [13] Amperometric glucose biosensor based on lipid film
    Wu, ZY
    Wang, BQ
    Dong, SJ
    Wang, EK
    BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4): : 143 - 147
  • [14] Amperometric glucose biosensor based on silver nanowires and glucose oxidase
    Wang, Lisha
    Gao, Xia
    Jin, Lingyan
    Wu, Qi
    Chen, Zhichun
    Lin, Xianfu
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 9 - 14
  • [15] Amperometric glucose biosensor based on layer-by-layer films of microperoxidase-11 and liposome-encapsulated glucose oxidase
    Graca, J. S.
    de Oliveira, R. F.
    de Moraes, M. L.
    Ferreira, M.
    BIOELECTROCHEMISTRY, 2014, 96 : 37 - 42
  • [16] Thermoresponsive amperometric glucose biosensor
    Pinyou, Piyanut
    Ruff, Adrian
    Poeller, Sascha
    Barwe, Stefan
    Nebel, Michaela
    Alburquerque, Natalia Guerrero
    Wischerhoff, Erik
    Laschewsky, Andre
    Schmaderer, Sebastian
    Szeponik, Jan
    Plumere, Nicolas
    Schuhmann, Wolfgang
    BIOINTERPHASES, 2016, 11 (01) : 1 - 7
  • [17] Non-enzymatic amperometric glucose biosensor based on nickel hexacyanoferrate nanoparticle film modified electrodes
    Wang, Xiaoyan
    Zhang, Yun
    Banks, Craig E.
    Chen, Qiyuan
    Ji, Xiaobo
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2010, 78 (02) : 363 - 366
  • [18] Amperometric glucose biosensor based on electrodeposition of platinum nanoparticles onto covalently immobilized carbon nanotube electrode
    Chu, Xia
    Duan, Daxue
    Shen, Guoli
    Yu, Ruqin
    TALANTA, 2007, 71 (05) : 2040 - 2047
  • [19] An amperometric glucose biosensor based on poly(o-aminophenol) and Prussian blue films at platinum electrode
    Pan, DW
    Chen, JH
    Nie, LH
    Tao, WY
    Yao, SZ
    ANALYTICAL BIOCHEMISTRY, 2004, 324 (01) : 115 - 122
  • [20] A microflow amperometric glucose biosensor
    Towe, Bruce C.
    Pizziconi, Vincent B.
    Biosensors and Bioelectronics, 1997, 12 (9-10): : 893 - 899