Demonstration of KHILS' two-color infrared (IR) projection capability

被引:4
|
作者
Jones, LE [1 ]
Coker, JS [1 ]
Garbo, DL [1 ]
Olson, EM [1 ]
Murrer, RL [1 ]
Bergin, T [1 ]
Goldsmith, GC [1 ]
Crow, DR [1 ]
Guertin, AW [1 ]
Dougherty, M [1 ]
Marler, TM [1 ]
Timms, VG [1 ]
机构
[1] Sci Applicat Int Corp, Shalimar, FL 32579 USA
关键词
IR two-color; KHILS; WISP; LWIR; MWIR; blackbody calibration; GWEF;
D O I
10.1117/12.316367
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
For more than a decade, there has been considerable discussion about using different IR bands for the detection of low contrast military targets. Theory predicts that a target can have little to no contrast against the background in one IR band while having a discernible signature in another IR band. A significant amount of effort has been invested towards establishing hardware that is capable of simultaneously imaging in two IR bands to take advantage of this phenomenon Focal plane arrays (FPA) are starting to materialize with this simultaneous two-color imaging capability. The Kinetic Kill Vehicle Hardware-in-the-loop Simulator (KHILS) team of the Air Force Research Laboratory and the Guided Weapons Evaluation Facility (GWEF), bath at Eglin AFB, FL, have spent the last 10 years developing the ability to project dynamic IR scenes to imaging IR seekers. Through the Wideband Infrared Scene Projector (WISP) program, the capability to project two simultaneous IR scenes to a dual color seeker has been established at KHILS. WISP utilizes resistor arrays to produce the IR energy. Resistor arrays are not ideal blackbodies. The projection of two IR colors with resistor arrays, therefore, requires two optically coupled arrays. This paper documents the first demonstration of two-color simultaneous projection at KHILS. Agema cameras were used for the measurements. The Agema's HgCdTe detector has responsivity from 4 to 14 microns. A blackbody and two IR filters (MWIR = 4.2 to 7.4 microns, LWIR = 7.7 to 13 microns) were used to calibrate the Agema in two bands. Each filter was placed in front of the blackbody one at a time, and the temperature of the blackbody was stepped up in incremental amounts. The output counts from the Agema were recorded at each temperature. This calibration process established the radiance to Agema output count curves for the two bands. The WISP optical system utilizes a dichroic beam combiner to optically couple the two resistor arrays. The transmission path of the beam combiner provided the LWIR (6.75 to 12 microns), while the reflective path produced the MWIR (3 to 6.5 microns). Each resistor array was individually projected into the Agema through the beam combiner at incremental output levels. Once again the Agema's output counts were recorded at each resistor array output level. These projections established the resistor array output to Agema count curves for the MWIR and LWIR resistor arrays. Using the radiance to Agema counts curves, the MWIR and LWIR resistor array output to radiance curves were established. With the calibration curves established a two-color movie was projected and compared to the generated movie radiance values. By taking care to correctly account for the spectral qualities of the Agema camera, the calibration filters, and the diachroic beam combiner, the projections matched the theoretical calculations. In the near future, a Lockheed-Martin Multiple Quantum Well camera with true two-color IR capability will be tested.
引用
收藏
页码:202 / 215
页数:14
相关论文
共 50 条
  • [31] SPECTRAL STUDY ON RESPONSE OF HgCdTe IR TWO-COLOR DETECTOR ARRAYS
    Ye Zhen-Hua
    Zhou Wen-Hong
    Hu Wei-Da
    Hu Xiao-Ning
    Ding Rui-Jun
    He Li
    JOURNAL OF INFRARED AND MILLIMETER WAVES, 2009, 28 (01) : 4 - 7
  • [32] Quantum-dot focal plane array has two-color capability
    Fischer, AL
    PHOTONICS SPECTRA, 2005, 39 (07) : 102 - 102
  • [33] A Two-Color Tumor
    Ramirez-Bellver, J. L.
    Enguita Valls, A. B.
    Sanchez-Carpintero, I.
    ACTAS DERMO-SIFILIOGRAFICAS, 2020, 111 (05): : 423 - 423
  • [34] Two-color nanoscopy
    不详
    SCIENTIST, 2007, 21 (05): : 72 - 72
  • [35] On two-color partitions
    Robbins, N
    UTILITAS MATHEMATICA, 2004, 65 : 193 - 199
  • [36] Development of a 2-color projection system for the KHILS VAcuum Cold Chamber (KVACC)
    Flynn, DS
    Marlow, SA
    Kircher, JR
    Glattke, EW
    Murrer, RL
    Weir, JS
    TECHNOLOGIES FOR SYNTHETIC ENVIRONMENTS: HARDWARE-IN-THE-LOOP TESTING V, 2000, 4027 : 236 - 247
  • [37] Two-color photoionization and photoelectron studies by combining infrared and vacuum ultraviolet
    Ng, CY
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 2005, 142 (03) : 179 - 192
  • [38] Two-color mid-infrared spectroscopy of isoelectronic centers in silicon
    Vinh, NQ
    Gregorkiewicz, T
    OPTOELECTRONICS OF GROUP-IV-BASED MATERIALS, 2003, 770 : 11 - 14
  • [39] Voltage tunable two-color infrared detection using semiconductor superlattices
    Majumdar, A
    Choi, KK
    Reno, JL
    Tsui, DC
    APPLIED PHYSICS LETTERS, 2003, 83 (25) : 5130 - 5132
  • [40] Multi-chord IR-visible two-color interferometer on KSTAR
    Juhn, June-Woo
    Lee, K. C.
    Lee, T. G.
    Wi, H. M.
    Kim, Y. S.
    Hahn, S. H.
    Nam, Y. U.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (04):