Evaluation of intra-aneurysmal hemodynamics after flow diverter placement in a patient-specific aneurysm model

被引:9
|
作者
Balasso, Andrea [1 ]
Bauer, Jan S. [1 ]
Liebig, Thomas [2 ]
Dorn, Franziska [2 ]
Zimmer, Claus [1 ]
Liepsch, Dieter [3 ]
Prothmann, Sascha [1 ]
机构
[1] Tech Univ Munich, Klinikum Rechts Isar, Dept Neuroradiol, D-80290 Munich, Germany
[2] Univ Cologne, Dept Neuroradiol, D-50931 Cologne, Germany
[3] Munich Univ Appl Sci, Munich, Germany
关键词
Stent; flow diversion; endovascular; non-Newtonian fluid; laser Doppler anemometry; PIPELINE EMBOLIZATION DEVICE; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; SACCULAR ANEURYSMS; STENT; ARTERY; RECONSTRUCTION; THROMBOSIS; RUPTURE; STRESS;
D O I
10.3233/BIR-14019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
BACKGROUND: The growth and rupture of cerebral aneurysms is intrinsically related to the hemodynamics prevailing in the diseased area. Therefore, a better understanding of intra-aneurysmal hemodynamics is essential for developing effective treatment methods. OBJECTIVE: The intention of this study was to evaluate the intra-aneurysmal flow and flow reduction induced by flow diverters in a true-to-scale elastic aneurysm model, obtained from real patient data. METHODS: Based on the computed tomography angiography (CTA) data of a fusiform aneurysm of a 34 year old patient, an elastic silicon rubber model of the aneurysm was produced. A physiologic pulsatile flow was created with a circulatory experimental set-up, and a non-Newtonian perfusion fluid was used as a substitute for human blood. Hemodynamics were measured by LDA before and after flow diverter implantation. RESULTS: Implantation of a flow diverter device resulted in a reduction of intra-aneurysmal maximum flow velocities of 97.8% at the inflow zone, 89.1% in the dome and 89.3% at the outflow zone, when compared to the native model. A significant reduction of 94% in the mean intra-aneurysmal velocity was found. CONCLUSIONS: This promising methodology can optimize patient treatment and will correlate with computational simulations to evaluate their reliability.
引用
收藏
页码:341 / 354
页数:14
相关论文
共 50 条
  • [41] Intra-aneurysmal flow rates are reduced by two flow diverters: an experiment using tomographic particle image velocimetry in an aneurysm model
    Dennis, Kendall D.
    Rossman, Timothy L.
    Kallmes, David F.
    Dragomir-Daescu, Dan
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (12) : 937 - 942
  • [42] CFD and MRI studies of hemodynamic changes after flow diverter implantation in a patient-specific model of the cerebral artery
    S. V. Frolov
    S. V. Sindeev
    J. S. Kirschke
    P. Arnold
    S. Prothmann
    D. Liepsch
    A. Balasso
    A. Potlov
    I. Larrabide
    S. Kaczmarz
    Experiments in Fluids, 2018, 59
  • [43] Intra-aneurysmal hemodynamics during the growth of an unruptured aneurysm: In vitro study using longitudinal CT angiogram database
    Tateshima, S.
    Tanishita, K.
    Omura, H.
    Villablanca, J. P.
    Vinuela, F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (04) : 622 - 627
  • [44] The pretzel sign: angiographic pattern of tortuous intra-aneurysmal blood flow in a giant serpentine aneurysm
    Fanning, NF
    Kelleher, MO
    Ryder, DQ
    BRITISH JOURNAL OF NEUROSURGERY, 2003, 17 (01) : 67 - 71
  • [45] De novo aneurysm formation after flow diverter stent placement
    Imaoka, Yukihiro
    Iihoshi, Satoshi
    Iijima, Shohei
    Sato, Hiroki
    Kohyama, Shinya
    NEUROLOGICAL SCIENCES, 2023, 44 (11) : 4129 - 4132
  • [46] De novo aneurysm formation after flow diverter stent placement
    Yukihiro Imaoka
    Satoshi Iihoshi
    Shohei Iijima
    Hiroki Sato
    Shinya Kohyama
    Neurological Sciences, 2023, 44 : 4129 - 4132
  • [47] Numerical simulation of hemodynamics in stented internal carotid aneurysm based on patient-specific model
    Fu, Wenyu
    Gu, Zhaoyong
    Meng, Xianlong
    Chu, Bo
    Qiao, Aike
    JOURNAL OF BIOMECHANICS, 2010, 43 (07) : 1337 - 1342
  • [48] Effect of aneurysm and ICA morphology on hemodynamics before and after flow diverter treatment
    Larrabide, Ignacio
    Geers, Arjan J.
    Morales, Hernan G.
    Aguilar, Martha L.
    Ruefenacht, Daniel A.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (04) : 272 - 280
  • [49] Analysis of flow patterns in a patient-specific thoracic aortic aneurysm model
    Tan, F. P. P.
    Borghi, A.
    Mohiaddin, R. H.
    Wood, N. B.
    Thom, S.
    Xu, X. Y.
    COMPUTERS & STRUCTURES, 2009, 87 (11-12) : 680 - 690
  • [50] Efficient parallel simulation of hemodynamics in patient-specific abdominal aorta with aneurysm
    Qin, Shanlin
    Wu, Bokai
    Liu, Jia
    Shiu, Wen-Shin
    Yan, Zhengzheng
    Chen, Rongliang
    Cai, Xiao-Chuan
    Chen, Rongliang (rl.chen@siat.ac.cn); Cai, Xiao-Chuan (xccai@um.edu.mo), 1600, Elsevier Ltd (136):