Improvement of the reliability of ceramic hip joint implants

被引:22
|
作者
Weisse, B
Zahner, M
Weber, W
Rieger, W
机构
[1] EMPA, Swiss Fed Labs Mat Testing & Res, Lab Strenght Technol, CH-8600 Dubendorf, Switzerland
[2] TKT Metoxit AG, CH-8240 Thayngen, Switzerland
关键词
ceramic ball head; failure; material flaw; finite element; hip joint implant; proof test; reliability;
D O I
10.1016/S0021-9290(03)00186-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The aim of this article is to present the optimization of a proof test procedure of ceramic hip joint ball heads. The proof test rejects defective samples in the production line before being implanted into human body. Thereby on every ceramic ball head a static load is applied, which is somewhat higher than the maximum physiological load. The magnitude of the applied load should not damage the samples which are free of flaws in the high stress area. The configuration of the proof test influences the stress distribution in the ball head, which should be similar to the physiological case. To determine the stress distribution, a non-linear finite element (FE) analysis was performed and the results were validated by measurements. With an iterative approach based on FE calculations the proof test configuration was optimized in such a way that the stress distribution in the ball head is similar to the stress distribution in vivo. In this study all ball heads showed very high fatigue resistance after being proof tested and fulfilled the requirements of the FDA (Food and Drug Administration, USA) described in the Guidance Document for the Preparation of Premarket Notifications for Ceramic Ball Hip System. The probability of a fracture of an implanted ceramic ball head can be decreased by the presented optimized proof test procedure. Latter can thus improve the reliability of ceramic hip joint ball heads. The study was supported by the KTI (Commission for Technology and Innovation, Switzerland). (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1633 / 1639
页数:7
相关论文
共 50 条
  • [31] Analysis of contact mechanics and lubrication in ceramic-on-ceramic hip joint replacements
    Mak, MM
    Jin, ZM
    BIOCERAMICS 14, 2002, 218-2 : 531 - 534
  • [32] Effect of microseparation on contact mechanics in ceramic-on-ceramic hip joint replacements
    Mak, MM
    Besong, AA
    Jin, ZM
    Fisher, J
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H6) : 403 - 408
  • [33] FRICTION-INDUCED SQUEAK OF CERAMIC-ON-CERAMIC HIP IMPLANTS: A STABILITY DESIGN CRITERIA
    Sidebottom, Mark
    Paliwal, Manish
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 2: BIOMEDICAL AND BIOTECHNOLOGY, 2013, : 877 - 881
  • [34] Effects of hydrogen peroxide solutions on artificial hip joint implants
    Shigematsu, M
    Kitajima, M
    Ogawa, K
    Higo, T
    Hotokebuchi, T
    JOURNAL OF ARTHROPLASTY, 2005, 20 (05): : 639 - 646
  • [35] Optimal parameters of abrasive flow finishing for hip joint implants
    Choopani, Yahya
    Khajehzadeh, Mohsen
    Razfar, Mohammad Reza
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 2021, 235 (11) : 1818 - 1831
  • [36] RELIABILITY ASPECTS OF METAL-CERAMIC JOINT STRUCTURES
    GNIRSS, G
    DANNHAUSER, G
    ZIGERLIG, B
    JOINING CERAMICS, GLASS AND METAL, 1989, : 221 - 234
  • [37] Ceramic chip scale package solder joint reliability
    Seyyedi, J
    Padgett, J
    SOLDERING & SURFACE MOUNT TECHNOLOGY, 2001, 13 (03) : 7 - 11
  • [38] Mechanical reliability of ceramic PTC components - Opportunities for improvement
    Supancic, P.
    Danzer, R.
    International Journal of Materials Research, 2004, 95 (07) : 607 - 617
  • [39] INVESTIGATIONS INTO THE MECHANICAL RELIABILITY OF CERAMIC FEMORAL HEADS FOR HIP JOINTS
    MIDDLETON, J
    PANDE, GN
    RICHTER, HG
    WILLMANN, G
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (6-7) : 503 - 506
  • [40] Fatigue test of hip-joint cups with ceramic inserts
    Soltész, U
    Richter, HG
    Schäfer, R
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2002, 33 (08) : 470 - 473