Improvement of the reliability of ceramic hip joint implants

被引:22
|
作者
Weisse, B
Zahner, M
Weber, W
Rieger, W
机构
[1] EMPA, Swiss Fed Labs Mat Testing & Res, Lab Strenght Technol, CH-8600 Dubendorf, Switzerland
[2] TKT Metoxit AG, CH-8240 Thayngen, Switzerland
关键词
ceramic ball head; failure; material flaw; finite element; hip joint implant; proof test; reliability;
D O I
10.1016/S0021-9290(03)00186-6
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The aim of this article is to present the optimization of a proof test procedure of ceramic hip joint ball heads. The proof test rejects defective samples in the production line before being implanted into human body. Thereby on every ceramic ball head a static load is applied, which is somewhat higher than the maximum physiological load. The magnitude of the applied load should not damage the samples which are free of flaws in the high stress area. The configuration of the proof test influences the stress distribution in the ball head, which should be similar to the physiological case. To determine the stress distribution, a non-linear finite element (FE) analysis was performed and the results were validated by measurements. With an iterative approach based on FE calculations the proof test configuration was optimized in such a way that the stress distribution in the ball head is similar to the stress distribution in vivo. In this study all ball heads showed very high fatigue resistance after being proof tested and fulfilled the requirements of the FDA (Food and Drug Administration, USA) described in the Guidance Document for the Preparation of Premarket Notifications for Ceramic Ball Hip System. The probability of a fracture of an implanted ceramic ball head can be decreased by the presented optimized proof test procedure. Latter can thus improve the reliability of ceramic hip joint ball heads. The study was supported by the KTI (Commission for Technology and Innovation, Switzerland). (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1633 / 1639
页数:7
相关论文
共 50 条
  • [1] Improvement of the reliability of ceramic hip joint implants
    Weisse, Bernhard
    Zahner, Marcel
    EMPA (Swiss Federal Laboratories for Materials Testing and Research) Publication, 2002, (SPEC.RAPORT):
  • [2] Proof testing of ceramic femoral heads for hip joint implants
    Weisse, B.
    Affolter, C.
    Koller, R. E.
    Stutz, A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H9) : 1051 - 1059
  • [3] NONDESTRUCTIVE TESTING OF CERAMIC HIP JOINT IMPLANTS WITH LASER SPOT THERMOGRAPHY
    Roemer, J.
    Pieczonka, L.
    Juszczyk, M.
    Uhl, T.
    ARCHIVES OF METALLURGY AND MATERIALS, 2017, 62 (04) : 2133 - 2139
  • [4] Ceramic-on-ceramic implants in total hip arthroplasty
    Colwell, C
    D'Antonio, JA
    Capello, WN
    Hardwick, ME
    BIOCERAMICS 17, 2005, 284-286 : 1003 - 1006
  • [5] CERAMIC-ON-CERAMIC HIP IMPLANTS: ANALYSIS OF FRICTION INDUCED SQUEAL
    Sidebottom, Mark
    Allan, D. G.
    Paliwal, Manish
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2014, VOL 3, 2015,
  • [6] Ceramic/ceramic total hip replacement: The American experience with stryker implants
    Bierbaum, BE
    D'Antonio, J
    Capello, W
    Manley, M
    Deshmukh, R
    BIOCERAMICS IN JOINT ARTHROPLASTY, 2004, : 21 - 34
  • [7] Improvement of solder joint reliability between multilayer ceramic package and printed wiring board by new ceramic material
    Yamaguchi, K
    Higashi, M
    Hamada, N
    Yonekura, H
    Kunimatsu, Y
    47TH ELECTRONIC COMPONENTS & TECHNOLOGY CONFERENCE, 1997 PROCEEDINGS, 1997, : 1277 - 1282
  • [8] Comparative Effectiveness of Ceramic-on-Ceramic Implants in Stemmed Hip Replacement
    Sedrakyan, Art
    Graves, Stephen
    Bordini, Barbara
    Pons, Miquel
    Havelin, Leif
    Mehle, Susan
    Paxton, Elizabeth
    Barber, Thomas
    Cafri, Guy
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A : 34 - 41
  • [9] Improvement of solder joint reliability between multilayer ceramic package and printed wiring board
    Yamaguchi, K
    Higashi, M
    Hamada, N
    Yonekura, H
    Oike, S
    Kunimatsu, Y
    1ST 1997 IEMT/IMC SYMPOSIUM, 1997, : 342 - 347
  • [10] Stress and Reliability Analyses of the Hip Joint Endoprosthesis Ceramic Head with Macro and Micro Shape Deviations
    Fuis, V.
    Janicek, P.
    Houfek, L.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 1580 - +