Purpose: An implantable radiation dosimeter has been developed to monitor dose delivered at depth in patients undergoing external beam therapy. A clinical pilot study was conducted to test the safety, efficacy, and utility of the device. Methods and Materials: Ten patients, all with unresectable malignant disease, were enrolled to assess implantation risk and movement of the device in the body and to compare the in vivo measured dose to the value predicted by the treatment planning system software. Results: Migration of the sensor away from the point of original placement was noted in only 1 patient (due to unconsolidated host tissue) and no adverse events were recorded during the implantation procedure or thereafter. Daily dose measurements were recorded successfully for all sensors in all patients. Variance between measured and predicted dose values was reported as a frequency of error at the >= 5% and >= 8% levels. The error frequency at the >= 8% level was as high as 47%, 29%, and 21% for lung, prostate, and rectal tumors, respectively. Conclusions: The implantable dosimeter was found to be safe and effective in measuring dose at depth. There are many factors that can influence delivered dose, and the implantable dosimeter measures the net effect of these factors. The daily sensor readings provide a new tool for rigorous treatment quality assurance. (c) 2005 Elsevier Inc.
引用
收藏
页码:606 / 613
页数:8
相关论文
共 50 条
  • [1] An implantable radiation dosimeter for use in external beam radiation therapy
    Scarantino, CW
    Ruslander, DM
    Rini, CJ
    Mann, GG
    Nagle, HT
    Black, RD
    [J]. MEDICAL PHYSICS, 2004, 31 (09) : 2658 - 2671
  • [2] Commissioning of An Implantable Dosimeter for External Beam Radiation Therapy
    Buzurovic, I.
    Showalter, T.
    Dicker, A.
    Cao, J.
    Xiao, Y.
    Yu, Y.
    Harrison, A.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Feasibility Study and First Results of a Real Time Imaging Dosimeter for External Beam Radiation Therapy
    Price, S. G.
    Silvius, A. A.
    Izaguirre, E. W.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2822 - 2826
  • [4] A pilot study on in vivo dosimetry during external beam radiation therapy
    Scarantino, CW
    Rini, C
    Aquino, M
    Carrea, T
    Ornitz, R
    Anscher, M
    Black, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S587 - S587
  • [5] Performance characteristics and commissioning of MOSFET as an in-vivo dosimeter for high energy photon external beam radiation therapy
    Gopiraj, A.
    Billimagga, Ramesh S.
    Ramasubramanian, Velayudham
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2008, 13 (03) : 114 - 125
  • [6] Studies on the safety and efficacy of an in vivo dosimeter during radiation therapy
    Scarantino, C
    Anscher, M
    Aquino, M
    Carrea, T
    Prosnitz, R
    Lee, R
    Black, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S548 - S548
  • [7] Real-time in vivo Cherenkoscopy imaging during external beam radiation therapy
    Zhang, Rongxiao
    Gladstone, David J.
    Jarvis, Lesley A.
    Strawbridge, Rendall R.
    Hoopes, P. Jack
    Friedman, Oscar D.
    Glaser, Adam K.
    Pogue, Brian W.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (11)
  • [8] Initial results of a trial of preoperative external-beam radiation therapy and postoperative brachytherapy for retroperitoneal sarcoma
    Jones, JJ
    Catton, CN
    O'Sullivan, B
    Couture, J
    Heisler, RL
    Kandel, RA
    Swallow, CJ
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2002, 9 (04) : 346 - 354
  • [9] Initial results of a trial of preoperative external-beam radiation therapy and postoperative brachytherapy for retroperitoneal sarcoma
    Julia J. Jones
    Charles N. Catton
    Brian O’Sullivan
    Jean Couture
    Ryan L. Heisler
    Rita A. Kandel
    Carol J. Swallow
    [J]. Annals of Surgical Oncology, 2002, 9 (4) : 346 - 354
  • [10] An analysis of an implantable dosimeter system for external beam therapy
    Black, RD
    Scarantino, CW
    Mann, GG
    Anscher, MS
    Ornitz, RD
    Nelms, BE
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (01): : 290 - 300