A Realistic Breast Phantom Proposal for 3D Image Reconstruction in Digital Breast Tomosynthesis

被引:1
|
作者
Polat, Adem [1 ]
Kumrular, Raziye Kubra [2 ]
机构
[1] Canakkale Onsekiz Mart Univ, Dept Elect Elect Engn, TR-17100 Canakkale, Turkey
[2] Univ Southampton, Inst Sound & Vibrat Res, Southampton, Hants, England
关键词
DBT; digital breast tomosynthesis; SART; FBP; breast phantom; breast cancer; breast imaging; PHASE-CONTRAST TOMOGRAPHY; ITERATIVE RECONSTRUCTION; SOFTWARE PACKAGE; ALGORITHM; FRAMEWORK; TOOLBOX; OBJECTS;
D O I
10.1177/15330338221104567
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objectives: Iterative (eg, simultaneous algebraic reconstruction technique [SART]) and analytical (eg, filtered back projection [FBP]) image reconstruction techniques have been suggested to provide adequate three-dimensional (3D) images of the breast for capturing microcalcifications in digital breast tomosynthesis (DBT). To decide on the reconstruction method in clinical DBT, it must first be tested in a simulation resembling the real clinical environment. The purpose of this study is to introduce a 3D realistic breast phantom for determining the reconstruction method in clinical applications. Methods: We designed a 3D realistic breast phantom with varying dimensions (64(3)-512(3)) mimicking some structures of a real breast such as milk ducts, lobules, and ribs using TomoPhantom software. We generated microcalcifications, which mimic cancerous cells, with a separate MATLAB code and embedded them into the phantom for testing and benchmark studies in DBT. To validate the characterization of the phantom, we tested the distinguishability of microcalcifications by performing 3D image reconstruction methods (SART and FBP) using Laboratory of Computer Vision (LAVI) open-source reconstruction toolbox. Results: The creation times of the proposed realistic breast phantom were seconds of 2.5916, 8.4626, 57.6858, and 472.1734 for 64(3), 128(3), 256(3), and 512(3), respectively. We presented reconstructed images and quantitative results of the phantom for SART (1-2-4-8 iterations) and FBP, with 11 to 23 projections. We determined qualitatively and quantitatively that SART (2-4 iter.) yields better results than FBP. For example, for 23 projections, the contrast-to-noise ratio (CNR) values of SART (2 iter.) and FBP were 2.871 and 0.497, respectively. Conclusions: We created a computationally efficient realistic breast phantom that is eligible for reconstruction and includes anatomical structures and microcalcifications, successfully. By proposing this breast phantom, we provided the opportunity to test which reconstruction methods can be used in clinical applications vary according to various parameters such as the No. of iterations and projections in DBT.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [1] 3D Medical Image Reconstruction on Digital Breast Tomosynthesis
    Duarte, Isabel Catarina
    Janela, Filipe
    Caldeira, Liliana
    Soares, Filipe
    Silva, Jose Silvestre
    2012 IEEE 2ND PORTUGUESE MEETING IN BIOENGINEERING (ENBENG), 2012,
  • [2] Validation of the Textural Realism of a 3D Anthropomorphic Phantom for Digital Breast Tomosynthesis
    Acciavatti, Raymond J.
    Hsieh, Meng-Kang
    Gastounioti, Aimilia
    Hu, Yifan
    Chen, Jinbo
    Maidment, Andrew D. A.
    Kontos, Despina
    14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [3] 3D Digital Breast Tomosynthesis Image Reconstruction Using Anisotropic Total Variation Minimization
    Seyyedi, Saeed
    Yildirim, Isa
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6052 - 6055
  • [4] Digital breast tomosynthesis image reconstruction using 2D and 3D total variation minimization
    Ertas, Metin
    Yildirim, Isa
    Kamasak, Mustafa
    Akan, Aydin
    BIOMEDICAL ENGINEERING ONLINE, 2013, 12
  • [5] Digital breast tomosynthesis image reconstruction using 2D and 3D total variation minimization
    Metin Ertas
    Isa Yildirim
    Mustafa Kamasak
    Aydin Akan
    BioMedical Engineering OnLine, 12
  • [6] Technical Note: Realization and uncertainty analysis for an adjustable 3D structured breast phantom in digital breast tomosynthesis
    Salomon, Elisabeth
    Unger, Ewald
    Homolka, Peter
    Cockmartin, Lesley
    Petrov, Dimitar
    Semturs, Friedrich
    Songsaeng, Chatsuda
    Panagiotis, Kapetas
    Vancoillie, Liesbeth
    Figl, Michael
    Sommer, Alexander
    Bosmans, Hilde
    Hummel, Johann
    MEDICAL PHYSICS, 2023, 50 (08) : 4816 - 4824
  • [7] Analysis of the utility of 3D digital breast tomosynthesis
    Kikuyama, M.
    Kato, M.
    Kaisaki, S.
    Yao, Y.
    Sakatani, T.
    BREAST, 2019, 44 : S51 - S52
  • [8] Development of an analytic breast phantom for quantitative comparison of reconstruction algorithms for digital breast tomosynthesis
    Reiser, I.
    Sidky, E. Y.
    Nishikawa, R. M.
    Pan, X.
    DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 190 - 196
  • [9] Validation and Optimization of Digital Breast Tomosynthesis Reconstruction using an Anthropomorphic Software Breast Phantom
    Bakic, Predrag R.
    Ng, Susan
    Ringer, Peter
    Carton, Ann-Katherine
    Conant, Emily F.
    Maidment, Andrew D. A.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [10] 3D digital breast tomosynthesis versus US in evaluating breast asymmetries
    Mokhtar, Omnia
    Abd Elsalam, Sahar
    Gamal, Gehan
    Naguib, Eman
    Gomaa, Manal
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2020, 51 (01):