Fast Registration of Intraoperative Ultrasound and Preoperative MR Images Based on Calibrations of 2D and 3D Ultrasound Probes

被引:4
|
作者
Chen, Fang [1 ]
Liao, Ruizhi [1 ]
Liao, Hongen [1 ]
机构
[1] Tsinghua Univ, Sch Med, Dept Biomed Engn, 1 Qinghuayuan, Beijing 100084, Peoples R China
关键词
calibration; registration; ultrasound guidance; TRACKING;
D O I
10.1007/978-3-319-19387-8_53
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
During the intraoperative-ultrasound-guided intervention, ultrasound (US) is often registered with other high-quality preoperative images like computed tomography (CT) or magnetic resonance (MR) to improve the navigation accuracy. However, real-time registration is difficult to achieve due to the difference of image modality and dimensionality. To solve this problem, we apply preoperative 3D US image collected with a 3D calibrated probe to simplify 2D US and 3D MR image registration into two easy-achieved steps: 2D-3D US intra-modal registration and 3D US 3D MR pre-operative registration. To achieve fast intraoperative 2D US and preoperative 3D US registration, we take advantage of effective 2D and 3D US probes' calibration results and get a near optimal registration transform. Then intraoperatively we just need to do an automatic local adjustment, which will make real-time registration become possible. To achieve effective calibrations, we design an improved calibration phantom and propose a warm-start iterative closest points (ICP) method.
引用
收藏
页码:220 / 223
页数:4
相关论文
共 50 条
  • [1] 3D Rigid Registration of Intraoperative Ultrasound and Preoperative MR Brain Images Based on Hyperechogenic Structures
    Coupe, Pierrick
    Hellier, Pierre
    Morandi, Xavier
    Barillot, Christian
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2012, 2012
  • [2] Model-Based Deformable Registration of Preoperative 3D to Intraoperative Low-Resolution 3D and 2D Sequences of MR Images
    Marami, Bahram
    Sirouspour, Shahin
    Capson, David W.
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 460 - 467
  • [3] Rigid 2D/3D registration of intraoperative digital X-ray images and preoperative CT and MR images
    Tomazevic, D
    Likar, B
    Pernus, F
    [J]. MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 507 - 517
  • [4] Efficient automatic 2D/3D registration of cardiac ultrasound and CT images
    Scott, Katy
    Stuart, Duncan
    Peoples, Jacob J.
    Bisleri, Gianluigi
    Ellis, Randy E.
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2021, 9 (04): : 438 - 446
  • [5] Registration of intraoperative 3D ultrasound with MR data for the navigated computer based surgery
    Dekomien, Claudia
    Mildenstein, Markus
    Hensel, Karin
    Hold, Stephanie
    Winter, Susanne
    [J]. ADVANCES IN MEDICAL ENGINEERING, 2007, 114 : 252 - +
  • [6] Automated Registration of 3D Ultrasound and CT/MR Images for Liver
    Haque, Hasnine
    Omi, Yasuo
    Rusko, Laszlo
    Annangi, Pavan
    Kazuyuki, Ohmura
    [J]. 2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [7] Fast Learning Framework for Denoising of Ultrasound 2D Videos and 3D Images
    Cammarasana, Simone
    Nicolardi, Paolo
    Patane, Giuseppe
    [J]. IMAGE ANALYSIS AND PROCESSING, ICIAP 2022 WORKSHOPS, PT I, 2022, 13373 : 475 - 486
  • [8] Elastic registration of 3D ultrasound images
    Foroughi, P
    Abolmaesumi, P
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 1, 2005, 3749 : 83 - 90
  • [9] Model-based 3D/2D Deformable Registration of MR Images
    Marami, Bahram
    Sirouspour, Shahin
    Capson, David W.
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 4880 - 4883
  • [10] Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images
    Weon, Chijun
    Nam, Woo Hyun
    Lee, Duhgoon
    Lee, Jae Young
    Ra, Jong Beom
    [J]. MEDICAL PHYSICS, 2015, 42 (01) : 335 - 347