Model-Based Deformable Registration of Preoperative 3D to Intraoperative Low-Resolution 3D and 2D Sequences of MR Images

被引:0
|
作者
Marami, Bahram [1 ]
Sirouspour, Shahin [1 ]
Capson, David W. [1 ]
机构
[1] McMaster Univ, Dept Elect & Comp Engn, Hamilton, ON L8S 4K1, Canada
关键词
Image registration; soft-tissue deformation; MR imaging; breast biopsy; continuum mechanics; finite element method;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
We have developed an automatic model-based deformable registration method applicable to MR soft-tissue imaging. The registration algorithm uses a dynamic finite element (FE) continuum mechanics model of the tissue deformation to register its 3D preoperative images with intraoperative 1) 3D low-resolution or 2) 2D MR images. The registration is achieved through a filtering process that combines information from the deformation model and observation errors based on correlation ratio, mutual information or sum of square differences between images. Experimental results with a breast phantom show that the proposed method converges in few iterations in the presence of very large deformations, similar to those typically observed in breast biopsy applications.
引用
收藏
页码:460 / 467
页数:8
相关论文
共 50 条
  • [1] Model-based 3D/2D Deformable Registration of MR Images
    Marami, Bahram
    Sirouspour, Shahin
    Capson, David W.
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 4880 - 4883
  • [2] Fast Registration of Intraoperative Ultrasound and Preoperative MR Images Based on Calibrations of 2D and 3D Ultrasound Probes
    Chen, Fang
    Liao, Ruizhi
    Liao, Hongen
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 220 - 223
  • [3] Rigid 2D/3D registration of intraoperative digital X-ray images and preoperative CT and MR images
    Tomazevic, D
    Likar, B
    Pernus, F
    [J]. MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 507 - 517
  • [4] Towards 2D/3D Registration of the Preoperative MRI to Intraoperative Fluoroscopic Images for Visualisation or Bone Defects
    Ku, Ping-Cheng
    Martin-Gomez, Alejandro
    Gao, Cong
    Grupp, Robert
    Mears, Simon C.
    Armand, Mehran
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2023, 11 (04): : 1096 - 1105
  • [5] 3D Model-Based Segmentation of 3D Biomedical Images
    Woerz, Stefan
    [J]. MATHEMATICAL AND ENGINEERING METHODS IN COMPUTER SCIENCE, MEMICS 2014, 2014, 8934 : 40 - 46
  • [6] A robust and precise approach for model-based 3D/2D registration and tracking
    Meilhac, C
    Nastar, C
    [J]. SCIA '97 - PROCEEDINGS OF THE 10TH SCANDINAVIAN CONFERENCE ON IMAGE ANALYSIS, VOLS 1 AND 2, 1997, : 635 - 642
  • [7] 3D Rigid Registration of Intraoperative Ultrasound and Preoperative MR Brain Images Based on Hyperechogenic Structures
    Coupe, Pierrick
    Hellier, Pierre
    Morandi, Xavier
    Barillot, Christian
    [J]. INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2012, 2012
  • [8] Using multiple images and contours for deformable 3D–2D registration of a preoperative CT in laparoscopic liver surgery
    Yamid Espinel
    Lilian Calvet
    Karim Botros
    Emmanuel Buc
    Christophe Tilmant
    Adrien Bartoli
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 2211 - 2219
  • [9] 2D/3D deformable registration using a hybrid atlas
    Tang, TSY
    Ellis, RE
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 223 - 230
  • [10] LiftReg: Limited Angle 2D/3D Deformable Registration
    Tian, Lin
    Lee, Yueh Z.
    Estepar, Raul San Jose
    Niethammer, Marc
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2022, PT VI, 2022, 13436 : 207 - 216