Biomechanical Evaluation of Proximal Hamstring Repair: All-Suture Anchor Versus Titanium Suture Anchor

被引:5
|
作者
Otto, Alexander [1 ,2 ,3 ]
DiCosmo, Alyssa M. [1 ]
Baldino, Joshua B. [1 ]
Mehl, Julian [1 ,2 ]
Obopilwe, Elifho [1 ]
Cote, Mark P. [1 ]
Imhoff, Andreas B. [1 ,2 ]
Beitzel, Knut [1 ,2 ,4 ]
Mazzocca, Augustus D. [1 ,2 ]
Coyner, Katherine [1 ,2 ]
机构
[1] Univ Connecticut, UConn Musculoskeletal Inst, Dept Orthopaed Surg, 263 Farmington Ave, Farmington, CT 06030 USA
[2] Tech Univ Munich, Dept Orthopaed Sports Med, Klinikum Rechts Isar, Munich, Germany
[3] Univ Hosp Augsburg, Dept Trauma Orthopaed Plast & Hand Surg, Augsburg, Germany
[4] ATOS Orthoparc Klin Koln, Cologne, Germany
关键词
proximal hamstring avulsion; hip; all-suture anchor; titanium suture anchor; biomechanics; proximal hamstring repair; SURGICAL REPAIR; AVULSION INJURIES; TENDON RUPTURES; OUTCOMES; SPORTS; ORIGIN; TAPE;
D O I
10.1177/2325967119892925
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Proximal hamstring avulsions are severe tendon injuries and are commonly sports-related. Open and endoscopic techniques as well as different anchor configurations have already been described for proximal hamstring repair. Novel all-suture anchors have been developed to provide decreased bone loss during placement and reduced occupied bone volume when compared with titanium suture anchors. Hypothesis: Complete proximal hamstring avulsions repaired with all-suture anchors will demonstrate equal load to failure and comparable displacement under cyclic loading when compared with titanium suture anchors. Study Design: Controlled laboratory study. Methods: Complete proximal hamstring avulsions were created in 18 paired cadaveric specimens (mean +/- SD age, 63.0 +/- 10.4 years). Either all-suture anchors or titanium suture anchors were used for repair. Cyclic loading from 10 to 125 N at 1 Hz was performed for 1500 cycles with a material testing machine. Displacement was assessed along anterior and posterior aspects of the tendon repair with optical tracking. Specimens were loaded to failure at a rate of 120 mm/min. Displacement, load to failure, and repair construct stiffness were compared between matched pairs with the Wilcoxon signed-rank test. Correlations were determined by Spearman rho analysis. Results: The all-suture anchors showed significantly higher load-to-failure values when compared with the titanium anchor repairs (799.64 +/- 257.1 vs 573.27 +/- 89.9 N; P = .008). There was no significant difference in displacement between all-suture anchors and titanium suture anchors at the anterior aspect (6.60 +/- 2.2 vs 5.49 +/- 1.1 mm; P = .26) or posterior aspect (5.87 +/- 2.08 vs 5.23 +/- 1.37 mm; P = .678) of the repaired hamstring tendons. Conclusion: All-suture anchors demonstrated similar displacement and superior load to failure when compared with titanium suture anchors.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Biomechanical Analysis of Patellar Tendon Repair With Knotless Suture Anchor Tape Versus Transosseous Suture
    Massey, Patrick A.
    Myers, Mitchell
    McClary, Kaylan
    Brown, Jimmy
    Barton, R. Shane
    Solitro, Giovanni F.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (10)
  • [22] Biomechanical Comparison of Transosseous Versus Suture Anchor Repair of the Subscapularis Tendon
    Wheeler, Daniel J.
    Garabekyan, Tigran
    Lugo, Roberto
    Buckley, Jenni M.
    Jones, Christopher
    Lotz, Marielena
    Lotz, Jeffery C.
    Ma, C. Benjamin
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (04): : 444 - 450
  • [23] Comparison of Clinical Outcomes and Computed Tomography Analysis for Tunnel Diameter After Arthroscopic Bankart Repair With the All-Suture Anchor and the Biodegradable Suture Anchor
    Lee, Jae-Hoo
    Park, In
    Hyun, Hwan-Sub
    Kim, Sang-Woo
    Shin, Sang-Jin
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (05): : 1351 - 1358
  • [24] Biomechanical Comparison of a Knotless Suture Anchor With Standard Suture Anchor in the Repair of Type II SLAP Tears
    Sileo, Michael J.
    Lee, Steven J.
    Kremenic, Ian J.
    Orishimo, Karl
    Ben-Avi, Simon
    McHugh, Malachy
    Nicholas, Stephen J.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (04): : 348 - 354
  • [25] Biomechanical Evaluation of a Transtendinous All-Suture Anchor Technique Versus Interference Screw Technique for Suprapectoral Biceps Tenodesis in a Cadaveric Model
    Hong, Chih-Kai
    Hsu, Kai-Lan
    Kuan, Fa-Chuan
    Lin, Cheng-Li
    Yeh, Ming-Long
    Su, Wei-Ren
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2018, 34 (06): : 1755 - 1761
  • [26] Biomechanical Analysis of Medial-Row All-Suture Suture Anchor Fixation for Rotator Cuff Repair in a Pair-Matched Cadaveric Model
    Bernardoni, Eamon D.
    Frank, Rachel M.
    Veera, Shreya S.
    Waterman, Brian R.
    Griffin, Justin W.
    Shewman, Elizabeth F.
    Cole, Brian J.
    Romeo, Anthony A.
    Verma, Nikhil N.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (05): : 1370 - 1376
  • [27] Increased Load to Failure in Biceps Tenodesis With All-Suture Suture Anchor Compared With Interference Screw: A Cadaveric Biomechanical Study
    Smuin, Dallas M.
    Vannatta, Emily
    Ammerman, Brittany
    Stauch, Christopher M.
    Lewis, Gregory S.
    Dhawan, Aman
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2021, 37 (10): : 3016 - 3021
  • [28] Subpectoral Biceps Tenodesis: All-Suture Anchor Onlay Technique
    Lacheta, Lucca
    Imhoff, Andreas B.
    Siebenlist, Sebastian
    Scheiderer, Bastian
    ARTHROSCOPY TECHNIQUES, 2020, 9 (05): : E651 - E655
  • [29] Short-term outcomes after knotless all-suture anchor Bankart repair
    Tross, Anna-K.
    Nolte, Philip-C.
    Horan, Marilee B.
    Ruzbarsky, Joseph
    Elrick, Bryant P.
    Woolson, Thomas E.
    Millett, Peter J.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2021, 16 (01): : 27 - 33
  • [30] Two-Portal Arthroscopic Knotless All-Suture Anchor Posterior Labral Repair
    Khaleel, Mubinah
    Oladeji, Lasun O.
    Smith, Conor A.
    DeFroda, Steven F.
    Nuelle, Clayton W.
    ARTHROSCOPY TECHNIQUES, 2024, 13 (05):