Comparison of nighttime nitric oxide 5.3 μm emissions in the thermosphere measured by MIPAS and SABER

被引:19
|
作者
Gardner, J. L.
Funke, B.
Mlynczak, M. G.
Lopez-Puertas, M.
Martin-Torres, F. J.
Russell, J. M., III
Miller, S. M.
Sharma, R. D.
Winick, J. R.
机构
[1] Stewart Radiance Lab, Bedford, MA 01730 USA
[2] CSIC, Inst Astrofis Andalucia, E-18080 Granada, Spain
[3] NASA Langley Res Ctr, Sci Directorate, Hampton, VA 23681 USA
[4] Analyt Serv & Mat Inc, NASA Langley Res Ctr, Hampton, VA 23681 USA
[5] Hampton Univ, Ctr Atmospher Sci, Hampton, VA 23668 USA
[6] Hanscom AFB, Space Vehicles Directorate, Air Force Res Lab, Bedford, MA 01731 USA
关键词
D O I
10.1029/2006JA011984
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
[1] A comparative study of nitric oxide (NO) 5.3 mu m emissions in the thermosphere measured by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) spectrometer and the Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) radiometer satellite instruments was conducted for nighttime data collected on 14 June 2003. The agreement between the data sets was very good, within similar to 25% over the entire latitude range studied from -58 degrees to + 4 degrees. The MIPAS and SABER data were inverted to retrieve NO volume emission rates. Spectral fitting of the MIPAS data was used to determine the NO(v= 1) rotational and spin-orbit temperatures, which were found to be in nonlocal thermodynamic equilibrium (non-LTE) above 110 km. Near 110 km the rotational and spin-orbit temperatures converged, indicating the onset of equilibrium in agreement with the results of non-LTE modeling. Because of the onset of equilibrium the NO rotational and spin-orbit temperatures can be used to estimate the kinetic temperature near 110 km. The results indicate that the atmospheric model NRLMSISE-00 underestimates the kinetic temperature near 110 km for the locations investigated. The SABER instrument 5.3 mm band filter cuts off a significant fraction of the NO(Delta v = 1) band, and therefore modeling of NO is necessary to predict the total band radiance. The needed correction factors were directly determined from the MIPAS data, providing validation of the modeled values used in SABER operational data processing. The correction factors were applied to the SABER data to calculate densities of NO(v = 1). A feasibility study was also conducted to investigate the use of NO 5.3 mm emission data to derive NO(v = 0) densities in the thermosphere.
引用
收藏
页数:10
相关论文
共 38 条
  • [11] Empirical model of the nitric oxide emission 5.3 μm in the upper atmosphere
    Semenov, A. I.
    Medvedeva, I. V.
    Perminov, V. I.
    Khomich, V. Yu.
    Zheleznov, Yu. A.
    24TH INTERNATIONAL SYMPOSIUM ON ATMOSPHERIC AND OCEAN OPTICS: ATMOSPHERIC PHYSICS, 2018, 10833
  • [12] Thermospheric nitric oxide infrared emissions measured by CRISTA
    Grossmann, KU
    Kaufmann, M
    Vollmann, K
    MIDDLE AND UPPER ATMOSPHERES: SMALL SCALE STRUCTURES AND REMOTE SENSING, 1997, 19 (04): : 591 - 594
  • [13] A first-principles model of spectrally resolved 5.3 μm nitric oxide emission from aurorally dosed nighttime high-altitude terrestrial thermosphere -: art. no. L17108
    Duff, JW
    Dothe, H
    Sharma, RD
    GEOPHYSICAL RESEARCH LETTERS, 2005, 32 (17) : 1 - 4
  • [14] Solar Cycle Variability of Nonmigrating Tides in the 5.3 and 15 μm Infrared Cooling of the Thermosphere (100-150 km) from SABER
    Nischal, N.
    Oberheide, J.
    Mlynczak, M. G.
    Marsh, D. R.
    Gan, Q.
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2019, 124 (03) : 2338 - 2356
  • [15] The natural thermostat of nitric oxide emission at 5.3 μm in the thermosphere observed during the solar storms of April 2002 -: art. no. 2100
    Mlynczak, M
    Martin-Torres, FJ
    Russell, J
    Beaumont, K
    Jacobson, S
    Kozyra, J
    Lopez-Puertas, M
    Funke, B
    Mertens, C
    Gordley, L
    Picard, R
    Winick, J
    Wintersteiner, P
    Paxton, L
    GEOPHYSICAL RESEARCH LETTERS, 2003, 30 (21)
  • [16] Spatial and Temporal Variations of Infrared Emissions in the Upper Atmosphere. 3. 5.3-μm Nitric Oxide Emission
    Semenov, A. I.
    Medvedeva, I. V.
    Perminov, V. I.
    GEOMAGNETISM AND AERONOMY, 2018, 58 (02) : 273 - 280
  • [17] Spatial and Temporal Variations of Infrared Emissions in the Upper Atmosphere. 3. 5.3-μm Nitric Oxide Emission
    A. I. Semenov
    I. V. Medvedeva
    V. I. Perminov
    Geomagnetism and Aeronomy, 2018, 58 : 273 - 280
  • [18] MIPAS temperature from the stratosphere to the lower thermosphere: Comparison of vM21 with ACE-FTS, MLS, OSIRIS, SABER, SOFIE and lidar measurements
    Garcia-Comas, M.
    Funke, B.
    Gardini, A.
    Lopez-Puertas, M.
    Jurado-Navarro, A.
    von Clarmann, T.
    Stiller, G.
    Kiefer, M.
    Boone, C. D.
    Leblanc, T.
    Marshall, B. T.
    Schwartz, M. J.
    Sheese, P. E.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2014, 7 (11) : 3633 - 3651
  • [19] Line mixing study on the fundamental rovibrational band of nitric oxide near 5.3 μm
    Su, Wey-Wey
    Boulet, Christian
    Almodovar, Christopher A.
    Ding, Yiming
    Strand, Christopher L.
    Hanson, Ronald K.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2022, 278
  • [20] Retrieval of stratospheric NOx from 5.3 and 6.2 μm nonlocal thermodynamic equilibrium emissions measured by Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) on Envisat -: art. no. D09302
    Funke, B
    López-Puertas, M
    von Clarmann, T
    Stiller, GP
    Fischer, H
    Glatthor, N
    Grabowski, U
    Höpfner, M
    Kellmann, S
    Kiefer, M
    Linden, A
    Tsidu, GM
    Milz, M
    Steck, T
    Wang, DY
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 2005, 110 (D9) : 1 - 13