Comparison of nighttime nitric oxide 5.3 μm emissions in the thermosphere measured by MIPAS and SABER

被引:19
|
作者
Gardner, J. L.
Funke, B.
Mlynczak, M. G.
Lopez-Puertas, M.
Martin-Torres, F. J.
Russell, J. M., III
Miller, S. M.
Sharma, R. D.
Winick, J. R.
机构
[1] Stewart Radiance Lab, Bedford, MA 01730 USA
[2] CSIC, Inst Astrofis Andalucia, E-18080 Granada, Spain
[3] NASA Langley Res Ctr, Sci Directorate, Hampton, VA 23681 USA
[4] Analyt Serv & Mat Inc, NASA Langley Res Ctr, Hampton, VA 23681 USA
[5] Hampton Univ, Ctr Atmospher Sci, Hampton, VA 23668 USA
[6] Hanscom AFB, Space Vehicles Directorate, Air Force Res Lab, Bedford, MA 01731 USA
关键词
D O I
10.1029/2006JA011984
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
[1] A comparative study of nitric oxide (NO) 5.3 mu m emissions in the thermosphere measured by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) spectrometer and the Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) radiometer satellite instruments was conducted for nighttime data collected on 14 June 2003. The agreement between the data sets was very good, within similar to 25% over the entire latitude range studied from -58 degrees to + 4 degrees. The MIPAS and SABER data were inverted to retrieve NO volume emission rates. Spectral fitting of the MIPAS data was used to determine the NO(v= 1) rotational and spin-orbit temperatures, which were found to be in nonlocal thermodynamic equilibrium (non-LTE) above 110 km. Near 110 km the rotational and spin-orbit temperatures converged, indicating the onset of equilibrium in agreement with the results of non-LTE modeling. Because of the onset of equilibrium the NO rotational and spin-orbit temperatures can be used to estimate the kinetic temperature near 110 km. The results indicate that the atmospheric model NRLMSISE-00 underestimates the kinetic temperature near 110 km for the locations investigated. The SABER instrument 5.3 mm band filter cuts off a significant fraction of the NO(Delta v = 1) band, and therefore modeling of NO is necessary to predict the total band radiance. The needed correction factors were directly determined from the MIPAS data, providing validation of the modeled values used in SABER operational data processing. The correction factors were applied to the SABER data to calculate densities of NO(v = 1). A feasibility study was also conducted to investigate the use of NO 5.3 mm emission data to derive NO(v = 0) densities in the thermosphere.
引用
收藏
页数:10
相关论文
共 38 条
  • [1] On the rotational distribution of the 5.3-mu m ''thermal'' emission from nitric oxide in the nighttime terrestrial thermosphere
    Sharma, RD
    Dothe, H
    vonEsse, F
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 1996, 101 (A8) : 17129 - 17135
  • [2] Global observations of thermospheric temperature and nitric oxide from MIPAS spectra at 5.3 μm
    Bermejo-Pantaleon, D.
    Funke, B.
    Lopez-Puertas, M.
    Garcia-Comas, M.
    Stiller, G. P.
    von Clarmann, T.
    Linden, A.
    Grabowski, U.
    Hoepfner, M.
    Kiefer, M.
    Glatthor, N.
    Kellmann, S.
    Lu, G.
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2011, 116
  • [3] Comparison of nitric oxide measurements in the mesosphere and lower thermosphere from ACE-FTS, MIPAS, SCIAMACHY, and SMR
    Bender, S.
    Sinnhuber, M.
    von Clarmann, T.
    Stiller, G.
    Funke, B.
    Lopez-Puertas, M.
    Urban, J.
    Perot, K.
    Walker, K. A.
    Burrows, J. P.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2015, 8 (10) : 4171 - 4195
  • [4] Studying nighttime nitric oxide emission at 5.3 μm during the geomagnetic storm in the Earth’s ionosphere
    Abdelaaziz Bouziane
    Mohammed Amin Ferdi
    Mourad Djebli
    Astrophysics and Space Science, 2022, 367
  • [5] Studying nighttime nitric oxide emission at 5.3 μm during the geomagnetic storm in the Earth's ionosphere
    Bouziane, Abdelaaziz
    Amin Ferdi, Mohammed
    Djebli, Mourad
    ASTROPHYSICS AND SPACE SCIENCE, 2022, 367 (01)
  • [6] Spectroscopy, gas kinetics, and opacity of thermospheric nitric oxide and implications for analysis of SABER infrared emission measurements at 5.3 μm
    Mlynczak, Martin G.
    Hunt, Linda A.
    Lopez-Puertas, Manuel
    Funke, Bernd
    Emmert, John
    Solomon, Stan
    Yue, Jia
    Russell, James M.
    Mertens, Chris
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2021, 268 (268):
  • [7] Correlations Between the Thermosphere's Semiannual Density Variations and Infrared Emissions Measured With the SABER Instrument
    Weimer, D. R.
    Mlynczak, M. G.
    Emmert, J. T.
    Doornbos, E.
    Sutton, E. K.
    Hunt, L. A.
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2018, 123 (10) : 8850 - 8864
  • [8] Nighttime nitric oxide densities in the Southern Hemisphere mesosphere-lower thermosphere
    Sheese, P. E.
    Gattinger, R. L.
    Llewellyn, E. J.
    Boone, C. D.
    Strong, K.
    GEOPHYSICAL RESEARCH LETTERS, 2011, 38
  • [9] Contribution of chemical processes to infrared emissions from nitric oxide in the thermosphere
    Venkataramani, Karthik
    Yonker, Justin D.
    Bailey, Scott. M.
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2016, 121 (03) : 2450 - 2461
  • [10] Impact of tropospheric tides on the nitric oxide 5.3 μm infrared cooling of the low-latitude thermosphere during solar minimum conditions
    Oberheide, J.
    Mlynczak, M. G.
    Mosso, C. N.
    Schroeder, B. M.
    Funke, B.
    Maute, A.
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2013, 118 (11) : 7283 - 7293