Respiratory-gated 18F-FDG PET imaging in lung cancer: effects on sensitivity and specificity

被引:18
|
作者
Daouk, Joel [1 ,2 ]
Leloire, Marie [2 ]
Fin, Loic [3 ]
Bailly, Pascal [1 ]
Morvan, Julie [1 ,2 ]
El Esper, Isabelle [1 ,2 ]
Saidi, Lazhar [1 ]
Moullart, Veronique [1 ]
Francois, Geraldine [4 ]
Jounieaux, Vincent [2 ,4 ]
Meyer, Marc-Etienne [1 ,2 ]
机构
[1] Amiens Univ Hosp, Dept Nucl Med, Amiens, France
[2] Univ Picardy Jules Verne, Sch Med, Amiens, France
[3] Amiens Univ Hosp, Clin Trial & Innovat Dept, Amiens, France
[4] Amiens Univ Hosp, Dept Resp Med, Amiens, France
关键词
PET; fluorine-18; fluorodeoxyglucose; respiratory motion; lung cancer; POSITRON-EMISSION-TOMOGRAPHY; PULMONARY-LESIONS; CORRELATED PET; NODULES; MOTION; QUANTITATION; DIAGNOSIS; ACCURACY;
D O I
10.1258/ar.2011.110018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Respiratory motion is known to deteriorate positron emission tomography (PET) images and may lead to potential diagnostic errors when a standardized uptake value (SUV) cut-off threshold is used to discriminate between benign and malignant lesions. Purpose: To evaluate and compare ungated and respiratory-gated 18F-fluorodeoxyglucose PET/computed tomography (CT) methods for the characterization of pulmonary nodules. Material and Methods: The list-mode acquisition during respiratory-gated PET was combined with a short breath-hold CT scan to form the CT-based images. We studied 48 lesions in 43 patients. PET images were analyzed in terms of the maximum SUV (SUVmax) and the lesion location. Results: Using receiver-operating characteristic (ROC) curves, the optimal SUV cut-off thresholds for the ungated and CT-based methods were calculated to be 2.0 and 2.2, respectively. The corresponding sensitivity values were 83% and 92%, respectively, with a specificity of 67% for both methods. The two methods gave equivalent performance levels for the upper and middle lobes (sensitivity 93%, specificity 62%). They differed for the lower lobes, where the CT-based method outperformed the ungated method (sensitivity values of 90% and 70%, respectively, and a specificity of 73% with both methods) - especially for lesions smaller than 15 mm. Conclusion: The CT-based method increased sensitivity and did not diminish specificity, compared with the ungated method. It was more efficient than the ungated method for imaging the lower lobes and smallest lesions, which are most affected by respiratory motion.
引用
收藏
页码:651 / 657
页数:7
相关论文
共 50 条
  • [41] Respiratory-gated FDG PET/CT for evaluation of pulmonary nodules
    Aga, Fumitoshi
    Yamamoto, Yuka
    Maeda, Yukito
    Takahashi, Yosuke
    Nishiyama, Yoshihiro
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [42] Evaluation of Gynecologic Cancer with MR Imaging, 18F-FDG PET/CT, and PET/MR Imaging
    Lee, Susanna I.
    Catalano, Onofrio A.
    Dehdashti, Farrokh
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03) : 436 - 443
  • [43] 18F-FDG PET/CT Imaging in Primary Staging of Colorectal Cancer
    Mihailovic, Jasna
    Ivanov, Olivera
    Matovina, Emil
    Ivanov, Dejan
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [44] The value of 18F-FDG PET/CT imaging in breast cancer staging
    Yararbas, Ulkem
    Avci, Neslihan Cetin
    Yeniay, Levent
    Argon, Aziz Murat
    BOSNIAN JOURNAL OF BASIC MEDICAL SCIENCES, 2018, 18 (01) : 72 - 79
  • [45] 18F-FDG PET/CT imaging of breast cancer in a lactating woman
    Aksoy, S. Y.
    Gortan, F. A.
    Ozdemir, E.
    Turkolmez, S.
    Halac, M.
    Sonmezoglu, K.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2016, 35 (02): : 135 - 136
  • [46] Imaging biomarkers in ovarian cancer: the role of 18F-FDG PET/CT
    Mapelli, Paola
    Incerti, Elena
    Fallanca, Federico
    Gianolli, Luigi
    Picchio, Maria
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 60 (02): : 93 - 102
  • [47] The role of 18F-FDG PET/CT imaging in the diagnosis of ovarian cancer
    Rubello, D.
    Marzola, M. C.
    Colletti, P. M.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2019, 38 (01): : 50 - 51
  • [48] Monte Carlo simulations of respiratory gated 18F-FDG PET for the assessment of volume measurement methods
    Vauclin, Sebastien
    Hapdey, Sebastien
    Michel, Christian
    Rebani, Hafid
    Buvat, Irene
    Edet-Sanson, Agathe
    Doyeux, Kaya
    Gardin, Isabelle
    Vera, Pierre
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3325 - +
  • [49] Reduction of respiratory effects on lung PET imaging with respiratory-gated acquisition associated with breath-hold CT
    Morvan, J.
    El Esper, I.
    Saidi, L.
    Moullart, V.
    Daouk, J.
    Fin, L.
    Bailly, P.
    Meyer, M. -E.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2008, 32 (12): : 600 - 606
  • [50] Prospective comparison of 18F-FDG PET/MRI and 18F-FDG PET/CT for thoracic staging of non-small cell lung cancer
    Julian Kirchner
    Lino M. Sawicki
    Felix Nensa
    Benedikt M. Schaarschmidt
    Henning Reis
    Marc Ingenwerth
    Simon Bogner
    Clemens Aigner
    Christian Buchbender
    Lale Umutlu
    Gerald Antoch
    Ken Herrmann
    Philipp Heusch
    European Journal of Nuclear Medicine and Molecular Imaging, 2019, 46 : 437 - 445