Development and Validation of Liquid Chromatography-Tandem Mass Spectrometry Method for Simple Analysis of Sumatriptan and its Application in Bioequivalence Study

被引:10
|
作者
Wichitnithad, Wisut [1 ,2 ]
Nantaphol, Siriwan [1 ,3 ]
Vicheantawatchai, Petploy [1 ,3 ]
Kiatkumjorn, Thanyaporn [1 ,3 ]
Wangkangwan, Wachirasak [3 ]
Rojsitthisak, Pornchai [2 ,4 ]
机构
[1] Pharma Nueva Co Ltd, Dept Bioanalyt Dev, Bangkok 10900, Thailand
[2] Chulalongkorn Univ, Nat Prod Ageing & Chron Dis Res Unit, Bangkok 10330, Thailand
[3] Pharma Nueva Co Ltd, Dept Clin Dev, Bangkok 10900, Thailand
[4] Chulalongkorn Univ, Fac Pharmaceut Sci, Dept Food & Pharmaceut Chem, Bangkok 10330, Thailand
关键词
sumatriptan; LC-MS; MS; liquid-liquid extraction; pharmacokinetics; bioequivalence; SOLID-PHASE EXTRACTION; HUMAN PLASMA; HUMAN SERUM; QUANTITATION; SUCCINATE; ASSAY;
D O I
10.3390/ph13020021
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
This work demonstrated a sensitive, selective, and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for quantitation of sumatriptan in human plasma samples. Terazosin was used as an internal standard to minimize the variability during sample processing and detection. Sample cleanup prior to chromatographic analysis was accomplished by liquid-liquid extraction (LLE) with tert-butyl methyl ether (t-BME). The separation was performed on a reversed-phase Symmetry (R) C18 column (150 x 4.6 mm i.d., 5 mu m) under a gradient mode, using a 0.2% formic acid aqueous solution and acetonitrile at a flow rate of 0.5 mL/min. Sumatriptan (m/z 296.26 (R) 251.05) and terazosin (m/z 388.10 (R) 290.25) were quantified using a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) under the positive ion mode. The method was fully validated following US-FDA and EMA guidelines. The LC-MS/MS assay had a calibration range of 0.5-50.0 ng/mL. The assay was precise and accurate with a between-run precision of <9.51%, and between-run accuracy between -7.27 to 8.30%. The developed method was subsequently applied in the determination of plasma concentration-time profile of a sumatriptan 50-mg tablet following oral administration in healthy volunteers.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Method development, validation and bioequivalence of varenicline in human plasma by liquid chromatography tandem mass spectrometry
    Al-Haj, Ayoub
    Alawi, Mahmoud
    Arafat, Tawfiq
    Hourani, Mohammad Khair
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 931 : 134 - 139
  • [22] A simple and accurate liquid chromatography-tandem mass spectrometry method for quantification of zonisamide in plasma and its application to a pharmacokinetic study
    Matar, Kamal M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 961 : 103 - 109
  • [23] Development and validation of a simple and sensitive liquid chromatography-tandem mass spectrometry method for quantifying trimetazidine in human plasma
    Zhou, Gan
    Tan, Zhi-Rong
    Ouyang, Dong-Sheng
    Chen, Yao
    Guo, Dong
    Xie, Hai-Tang
    Liu, Ying-Zi
    Fan, Lan
    Deng, Han-Wu
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2010, 37 (04) : 501 - 505
  • [24] Sensitive and selective liquid chromatography-tandem mass spectrometry method for the determination of metoclopramide in human plasma: application to a bioequivalence study
    Inamadugu, Jaswanth Kumar
    Damaramadugu, Rajasekhar
    Mullangi, Ramesh
    Ponneri, Venkateswarlu
    BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (09) : 1006 - 1014
  • [25] Application of a rapid and sensitive liquid chromatography-tandem mass spectrometry method for determination of bumetanide in human plasma for a bioequivalence study
    Patel, Dinesh S.
    Sharma, Naveen
    Patel, Mukesh C.
    Patel, Bhavin N.
    Shrivastav, Pranav S.
    Sanyal, Mallika
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 365 - 370
  • [26] Development and validation of a multiclass method for the analysis of antibiotic residues in eggs by liquid chromatography-tandem mass spectrometry
    Jimenez, V.
    Rubies, A.
    Centrich, F.
    Companyo, R.
    Guiteras, J.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (11) : 1443 - 1451
  • [27] Validation of liquid chromatography-tandem mass spectrometry method for urinary cortisol
    Li, D.
    White, A.
    Kao, T.
    Pudek, M.
    CLINICAL BIOCHEMISTRY, 2008, 41 (14-15) : 1276 - 1277
  • [28] Application of a high performance liquid chromatography-tandem mass spectrometry method for determination of buflomedil in human plasma for a bioequivalence study
    Ren, Li
    Yang, Chun
    Peng, Yan
    Li, Fan
    Li, Ying-hui
    Zheng, Heng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 935 : 41 - 46
  • [29] Ultrafast liquid chromatography-tandem mass spectrometry determination of donepezil in human plasma: application to a bioequivalence study
    Huang, Yan-Wen
    Ding, Li
    Chen, Yuan-Ming
    Lin, Wei-chen
    Lin, Fei
    Hsieh, Yunsheng
    TRANSLATIONAL AND CLINICAL PHARMACOLOGY, 2022, 30 (01) : 37 - 48
  • [30] Bioanalytical Method Development and Validation of Memantine in Human Plasma by High Performance Liquid Chromatography with Tandem Mass Spectrometry: Application to Bioequivalence Study
    Konda, Ravi Kumar
    Challa, B. R.
    Chandu, Babu Rao
    Chandrasekhar, Kothapalli B.
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2012, 2012