Optimal supply air temperature with respect to energy use in a constant air volume system

被引:0
|
作者
Johansson, D [1 ]
机构
[1] Lund Univ, Dept Bldg Phys, S-22100 Lund, Sweden
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
As a general rule, the built environment in the EU uses about 40% of the total energy use. A major part of this is used to provide buildings with the necessary heating and cooling. The energy use of a building can be decreased by proper controlling of the ventilation and indoor climate system. One way to decrease the energy use is to control the supply air temperature. This paper presents a method for an optimal supply air temperature regarding energy use for a ventilation system with constant air volume (CAV). A one-zone office with a CAV system, heating radiators and chilled beams was considered. The optimisation was done by minimising the sum of the different powers to heat the air, heat the radiators, cool the air, cool the chilled beams, run the fan and condense the vapour when the air supply air temperature was cooled below the dew point temperature. The energy saving potential was also analysed when the optimal supply air temperature is applied in a northern European climate. The annual energy use can be decreased significantly if the supply air temperature is optimised. An optimised supply air temperature should be possible with the controllers available on the market but the implementation of such a control strategy requires further research.
引用
收藏
页码:699 / 708
页数:10
相关论文
共 50 条
  • [21] Calculating Energy Efficiency Index of VRF System by Supply-Air Temperature Estimation
    Sako, Miho
    Hatano, Hisaaki
    Yano, Toru
    2018 IEEE 7TH GLOBAL CONFERENCE ON CONSUMER ELECTRONICS (GCCE 2018), 2018, : 815 - 817
  • [22] Comparison of constant volume energy storage systems based on compressed air
    Salyga, Stanislaw
    Szablowski, Lukasz
    Badyda, Krzysztof
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (05) : 8030 - 8040
  • [23] CONSTANT TEMPERATURE AIR BATH
    YAGER, BJ
    SMITH, PY
    JOURNAL OF CHEMICAL EDUCATION, 1971, 48 (12) : 839 - &
  • [24] Optimal air-supply mode of hybrid system with radiant cooling and dedicated outdoor air
    Yan Ding
    Zhe Tian
    Neng Zhu
    Journal of Central South University, 2015, 22 : 735 - 746
  • [25] Optimal air-supply mode of hybrid system with radiant cooling and dedicated outdoor air
    Ding Yan
    Tian Zhe
    Zhu Neng
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2015, 22 (02) : 735 - 746
  • [26] Optimal air-supply mode of hybrid system with radiant cooling and dedicated outdoor air
    丁研
    田喆
    朱能
    Journal of Central South University, 2015, 22 (02) : 735 - 746
  • [27] New Optimal Supply Air Temperature and Minimum Zone Air Flow Resetting Strategies for VAV Systems
    Nassif, Nabil
    Tahmasebi, Mostafa
    Ridwana, Iffat
    Ebrahimi, Pejman
    BUILDINGS, 2022, 12 (03)
  • [28] A study on the optimal air, load and source side temperature combination for a variable air and water volume ground source heat pump system
    Lin, Yaolin
    Wang, Huan
    Hu, Pingfang
    Yang, Wei
    Hu, Qiushi
    Zhu, Na
    Lei, Fei
    APPLIED THERMAL ENGINEERING, 2020, 178
  • [29] Required Energy for Outside Air Treatment in a Central Plant with Constant All-Air Volume Operation.
    Clain, Francois
    Promoclim E: Etudes Thermiques et Aerauliques, 1976, 7 E (03): : 217 - 222
  • [30] Optimal fresh-air utilization strategy based on isocost Line: Adaptability analysis for constant temperature and humidity air-conditioning system
    Wang, Cuiling
    Zhao, Zihao
    Wang, Baolong
    Cui, Mengdi
    Sustainable Energy Technologies and Assessments, 2024, 72