Gas laser lidar system optimization for hydrogen molecules monitoring in atmosphere

被引:2
|
作者
Laktushkin, GV [1 ]
Privalov, VE [1 ]
Shemanin, VG [1 ]
机构
[1] Balt State Tech Univ, St Petersburg, Russia
来源
关键词
D O I
10.1117/12.311952
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Back scattered vibrational Raman lidar eqution computer simulation for hydrogen molecules and its heavy isotopes with cuprum vapour and eximer lasers have been made to choose optimal lidar system for studied molecules monitoring in atmosphere. Background stray sunlight power were calculated to determine the minimum molecules concentration at ranging distance up to 6 km.
引用
收藏
页码:276 / 284
页数:9
相关论文
共 50 条
  • [41] A hydrogen gas concentration measurement method using the Raman lidar system
    Choi, In Young
    Baik, Sung Hoon
    Cha, Jung Ho
    Kim, Jin Ho
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2019, 30 (05)
  • [42] Remotely measuring the hydrogen gas by using portable Raman lidar system
    Choi, In Young
    Baik, Sung Hoon
    Choi, Young Soo
    OPTICA APPLICATA, 2021, 51 (01) : 37 - 49
  • [43] Probing hydrogen molecules with a laboratory Raman lidar
    E. I. Voronina
    V. E. Privalov
    V. G. Shemanin
    Technical Physics Letters, 2004, 30 : 178 - 179
  • [44] Probing hydrogen molecules with a laboratory raman lidar
    Voronina, EI
    Privalov, VE
    Shemanin, VG
    TECHNICAL PHYSICS LETTERS, 2004, 30 (03) : 178 - 179
  • [45] AN IMPROVED RAMAN LIDAR SYSTEM FOR THE REMOTE MEASUREMENT OF NATURAL-GAS RELEASES INTO THE ATMOSPHERE
    BILBE, RM
    BULLMAN, SJ
    SWAFFIELD, F
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1990, 1 (06) : 495 - 499
  • [46] Laser sensing of HF molecules in atmosphere
    Voronina, Ellina I.
    Privalov, Vadim E.
    Shemanin, Valery G.
    LASERS FOR MEASUREMENTS AND INFORMATION TRANSFER 2007, 2008, 7006
  • [47] Self-aligning lidar for the continuous monitoring of the atmosphere
    INFM , Università Federico II, Complesso Universitario di Monte S. Angelo, Via Cintia, 80126 Naples, Italy
    不详
    不详
    不详
    不详
    不详
    Appl. Opt., 21 (4758-4764):
  • [48] Self-aligning lidar for the continuous monitoring of the atmosphere
    Fiorani, L
    Armenante, M
    Capobianco, R
    Spinelli, N
    Wang, X
    APPLIED OPTICS, 1998, 37 (21): : 4758 - 4764
  • [49] Optimization of sampling structure on unmanned aerial vehicle for gas leakage monitoring in the atmosphere
    Ma, Denglong
    Guo, Sicheng
    Zhou, Yuxiang
    ROBOTICA, 2024,
  • [50] Coherent laser spectroscopy and Doppler lidar sensing in the atmosphere
    Vaughan, JM
    PHYSICA SCRIPTA, 1998, T78 : 73 - 81