Laboratory X-ray CCD camera electronics - a test bed for the Swift X-ray Telescope

被引:10
|
作者
Hill, JE [1 ]
Zugger, ME [1 ]
Shoemaker, J [1 ]
Witherite, ME [1 ]
Koch, S [1 ]
Chou, L [1 ]
Case, T [1 ]
Burrows, DN [1 ]
机构
[1] Penn State Univ, Dept Astron & Astrophys, University Pk, PA 16802 USA
关键词
X-ray; astronomy; gamma-ray burst; Swift; instrumentation; CCD; scientific satellite;
D O I
10.1117/12.409162
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The Perm State University Department of Astronomy and Astrophysics has been active in the design of X-ray CCD cameras for astronomy for over two decades, including sounding rocket systems, the CUBIC instrument on the SAC-B satellite and the ACIS camera on the Chandra satellite. Currently the group is designing and building an X-ray telescope (XRT), which will comprise part of the Swift Gamma-Ray Burst Explorer satellite. The Swift satellite, selected in October 1999 as one of two winners of NASA Explorer contracts, will - within one minute - detect, locate, and observe gamma-ray bursts simultaneously in the optical, ultraviolet, X-ray, and gamma-ray wavelengths using three co-aligned telescopes. The XRT electronics is required to read out the telescope's CCD sensor in a number of different ways depending on the observing mode selected. Immediately after the satellite re-orientates to observe a newly detected burst, the XRT will enter an imaging mode to determine the exact position of the burst. The location will then be transmitted to the ground, and the XRT wilt autonomously enter other modes as the X-ray intensity of the burst waxes and wanes. This paper will discuss the electronics for a laboratory X-ray CCD camera, which serves as a test bed for development of the Swift XRT camera. It will also touch upon the preliminary design of the flight camera, which is closely related. A major challenge is achieving performance and reliability goals within the cost constraints of an Explorer mission.
引用
收藏
页码:87 / 98
页数:12
相关论文
共 50 条
  • [21] Soft X-ray calibration for the NeXT X-ray telescope
    Maeda, Yoshitonto
    Hayashi, Takayuki
    Mori, Hideyuki
    Nakamura, Ryoko
    Satoh, Takuro
    Sekiguchi, Akiko
    Someya, Kentaro
    Tamura, Kensuke
    Ishida, Manabu
    Osawa, Takeyuki
    Shirata, Takayuki
    Suzuki, Masaki
    Ogasaka, Yasushi
    Furuzawa, Akhiro
    Haba, Yoshito
    Miyazawa, Takuya
    Kunieda, Hideyo
    Yamashita, Koujun
    Okajima, Takashi
    SPACE TELESCOPES AND INSTRUMENTATION 2008: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2008, 7011
  • [22] The X-ray CCD camera onboard the MAXI mission
    Tomida, Hiroshi
    INTERNATIONAL JOURNAL OF MICROGRAVITY SCIENCE AND APPLICATION, 2011, 28 (01): : 29 - 33
  • [23] USE OF A CCD ARRAY IN AN X-RAY PINHOLE CAMERA
    CAVAILLER, C
    HENRY, P
    LAUNSPACH, J
    MENS, A
    ROSTAING, M
    SAUNEUF, R
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 491 : 442 - 450
  • [24] An x-ray TV camera using a CCD array
    Krasnjuk, AA
    Stenin, VJ
    FIFTH CONFERENCE ON CHARGE-COUPLED DEVICES AND CCD SYSTEMS, 1996, 2790 : 100 - 102
  • [25] Soft X-ray response of the CCD camera (XIS)
    Shouho, M
    Katayama, H
    Katayama, K
    Kohmura, T
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Hashimotodani, K
    Koyama, K
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    ASTRONOMISCHE NACHRICHTEN, 1999, 320 (4-5) : 382 - 382
  • [26] Application of X-ray CCD camera in x-ray spot diagnosis of rod-pinch diode
    State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an
    710024, China
    Yuanzineng Kexue Jishu, 4 (759-764):
  • [27] Calibration of the x-ray CCD camera (XIS) for the ASTRO-E in the soft x-ray band
    Katayama, H
    Shouho, M
    Kohmura, T
    Katayama, K
    Ohta, M
    Tsunemi, H
    Kitamoto, S
    Hayashida, K
    Miyata, E
    Yoshita, K
    Koyama, K
    Ricker, G
    Bautz, MW
    Foster, R
    Kissel, S
    Doty, J
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 : 721 - 728
  • [28] Soft X-ray response of the X-ray CCD camera directly coated with Optical Blocking Layer
    Ikeda, S.
    Kohmura, T.
    Kawai, K.
    Kaneko, K.
    Watanabe, T.
    Tsunemi, H.
    Hayashida, K.
    Anabuki, N.
    Nakajima, H.
    Ueda, S.
    Tsuru, T. G.
    Dotani, T.
    Ozaki, M.
    Matsuta, K.
    Fujinaga, T.
    Kitamoto, S.
    Murakami, H.
    Hiraga, J.
    Mori, K.
    SUZAKU 2011: EXPLORING THE X-RAY UNIVERSE: SUZAKU AND BEYOND, 2012, 1427
  • [29] Development of the X-ray CCD camera for the MAXI mission
    Katayama, H
    Tomida, H
    Matsuoka, M
    Tsunemi, H
    Miyata, E
    Kamiyama, D
    Nemes, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 541 (1-2): : 350 - 356
  • [30] The impact of the in-orbit background and the X-ray source intensity on the centroiding accuracy of the Swift X-ray telescope
    Ambrosi, RM
    Hutchinson, IB
    Hill, J
    Cheruvu, C
    Abbey, AF
    Short, ADT
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 493 (1-2): : 67 - 78