Hepatic MR imaging: comparison of 2D and 3D gradient echo techniques

被引:31
|
作者
Kim, MJ [1 ]
Mitchell, DG [1 ]
Ito, K [1 ]
Kim, PN [1 ]
机构
[1] Thomas Jefferson Univ Hosp, Dept Radiol, Philadelphia, PA 19107 USA
来源
ABDOMINAL IMAGING | 2001年 / 26卷 / 03期
关键词
liver; MR-MR; pulse sequence;
D O I
10.1007/s002610000177
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: To compare fat-suppressed three-dimensional gradient echo (3D-GRE) and two-dimensional gradient echo (2D-GRE) techniques for hepatic magnetic resonance imaging. Methods: For 107 patients with suspected focal hepatic lesions, unenhanced 2D-GRE multislice in-phase and opposed-phase images and 3D-GRE images were obtained. Two radiologists independently and in random order reviewed the images. Quantitative analysis compared contrast-to-noise ratio (C/N) of liver masses and of the liver to spleen and signal-to-noise ratio (S/N) of the liver. Subjective grading of lesion conspicuity, confidence for lesion detection, artifacts, and overall image quality were also evaluated. Results: Conspicuity and confidence for focal lesions was statistically significantly higher on 3D-GRE than on 2D-GRE images, Liver-to-spleen C/N was higher on 3D-GRE images than on in-phase and opposed-phase 2D-GRE images (p < 0.01). Liver S/N was higher on in-phase 2D-GRE images than on 3D-GRE and opposed-phase 2D-GRE images (p < 0.001). Lesion-to-liver C/N was higher on 3D-GRE images than on 2D-GRE images for nonsolid lesions (p < 0.05), but there was no significant difference for solid lesions. Motion and pulsation artifacts were significantly fewer on 3D-GRE images, but graininess and shading were significantly higher. Overall image quality was not significantly different for the three sequences. Conclusion: Fat-suppressed 3D-GRE sequences can afford comparable or better image quality than 2D-GRE images and may have the potential to detect more focal hepatic lesions.
引用
收藏
页码:269 / 276
页数:8
相关论文
共 50 条
  • [41] SIMULATION OF SUSCEPTIBILITY ARTIFACTS IN 2D AND 3D FOURIER-TRANSFORM SPIN-ECHO AND GRADIENT-ECHO MAGNETIC-RESONANCE-IMAGING
    BAKKER, CJG
    BHAGWANDIEN, R
    MOERLAND, MA
    RAMOS, LMP
    MAGNETIC RESONANCE IMAGING, 1994, 12 (05) : 767 - 774
  • [42] Cervical spinal cord multiple sclerosis: evaluation with 2D multi-echo recombined gradient echo MR imaging
    White, Matthew L.
    Zhang, Yan
    Healey, Kathleen
    JOURNAL OF SPINAL CORD MEDICINE, 2011, 34 (01): : 93 - 98
  • [43] MR-IMAGING OF THE NORMAL MENINGES - COMPARISON OF CONTRAST-ENHANCEMENT PATTERNS ON 3D GRADIENT-ECHO AND SPIN-ECHO IMAGES
    FARN, JW
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 131 - 135
  • [44] Joint 2D and 3D phase processing for quantitative susceptibility mapping: application to 2D echo-planar imaging
    Wei, Hongjiang
    Zhang, Yuyao
    Gibbs, Eric
    Chen, Nan-Kuei
    Wang, Nian
    Liu, Chunlei
    NMR IN BIOMEDICINE, 2017, 30 (04)
  • [45] Use of speckle tracking to quantify global LV function: A comparison with 2D and 3D echo and magnetic resonance imaging
    Brown, Joseph K.
    Marwick, Thomas H.
    CIRCULATION, 2007, 116 (16) : 403 - 404
  • [46] Detecting brain gadolinium retention in MS with MRI: a comparison of 2D Spin Echo, 3D gradient echo, quantitative susceptibility mapping and magnetization transfer
    Cananau, C.
    Forslin, Y.
    Sjostrom, H.
    Bergendal, A.
    Fink, K.
    Wiberg, M. Kristoffersen
    Ouellette, R.
    Fredrikson, S.
    Granberg, T.
    MULTIPLE SCLEROSIS JOURNAL, 2021, 27 (2_SUPPL) : 408 - 409
  • [47] GUIDED 3D ECHOCARDIOGRAPHY - COMPARISON TO 1D AND 2D ECHO AND MAGNETIC-RESONANCE-IMAGING FOR LV MASS IN HUMANS
    KING, DL
    GOPAL, AS
    SHEN, ZQ
    KELLER, AM
    HYPERTENSION, 1993, 22 (03) : 440 - 440
  • [48] Gradient-based registration of 3D MR and 2D x-ray images
    Tomazevic, D
    Likar, B
    Pernus, F
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 327 - 332
  • [49] Imaging articular cartilage defects in the ankle joint with 3D fat-suppressed echo planar imaging: Comparison with conventional 3D fat-suppressed gradient echo imaging
    Ba-Ssalamah, A
    Schibany, N
    Puig, S
    Herneth, AM
    Noebauer-Huhmann, IM
    Trattnig, S
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) : 209 - 216
  • [50] Flexural modelling of continental lithosphere deformation: a comparison of 2D and 3D techniques
    Hodgetts, D
    Egan, SS
    Williams, GD
    TECTONOPHYSICS, 1998, 294 (1-2) : 1 - 20