A Comparison Study of Sensible and Latent Thermal Energy Storage Used in Domestic Hot Water Solar Heating System

被引:0
|
作者
Batista, Josip [1 ]
Lenic, Kristian [1 ]
Trp, Anica [1 ]
Torbarina, Fran [1 ]
机构
[1] Univ Rijeka, Fac Engn, Dept Thermodynam & Energy Engn, Rijeka, Croatia
关键词
domestic hot water solar system; sensible thermal energy storage; latent thermal energy storage; PHASE-CHANGE; PCM;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Numerical analysis of domestic hot water solar system with sensible and latent thermal energy storages (TES), for specific residential building, has been presented in this paper. Numerical models of systems are developed in the Trnsys environment, consisting of the sensible or latent thermal energy storage tank, the flat-plate solar collectors, pump, differential controller and auxiliary heating source. Realistic meteorological conditions and standard user load profile were used as input parameters. The latent thermal energy storage tank contains sodium acetate trihydrate with added graphite powder, as phase change material (PCM), filled in cylindrical capsules and integrated into the tank, filling approximately 11% of total tank volume. The set of transient numerical simulations has been performed for a different tank volume and collector area ratios, ranging from 0.03 to 0.16 m(3)/m(2) . The performance of latent thermal energy storage system is compared with conventional sensible thermal energy storage system in terms of: collector efficiency, system efficiency, solar fraction and auxiliary energy consumption. The results of simulations indicate that latent thermal energy storage has advantages for specific tank volume to collector ratios, when the average temperature inside the tank is approaching the melting temperature of PCM.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 50 条
  • [41] Numerical modeling of latent heat thermal energy storage integrated with heat pump for domestic hot water production
    Inkeri, E.
    Tynjälä, T.
    Nikku, M.
    Applied Thermal Engineering, 2022, 214
  • [42] Experimental Investigation on a Solar Thermal Energy Packed Bed Sensible Heat Storage Combined with Latent Heat Storage
    Kumar, Vineet
    Sehgal, Anuj Kumar
    Gupta, Abhishek
    ADVANCES IN FLUID AND THERMAL ENGINEERING, 2019, : 647 - 656
  • [43] Study on optimal allocation of solar photovoltaic thermal heat pump integrated energy system for domestic hot water
    Mi, Peiyuan
    Zhang, Jili
    Gao, Jin
    Han, Youhua
    RENEWABLE ENERGY, 2023, 219
  • [44] A novel composite PCM for seasonal thermal energy storage of solar water heating system
    Wu, Wei
    Wang, Xiaoyu
    Xia, Man
    Dou, Yiping
    Yin, Zhengyu
    Wang, Jun
    Lu, Ping
    RENEWABLE ENERGY, 2020, 161 : 457 - 469
  • [45] Parametric study of a scraped surface heat exchanger for latent energy storage for domestic hot water generation
    Egea, A.
    Garcia, A.
    Perez-Garcia, J.
    Herrero-Martin, R.
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [46] A comparison study of different latent thermal energy storage roles in heating systems with heat pump
    Torbarina, Fran
    Lenic, Kristian
    Trp, Anica
    Wolf, Igor
    PROCEEDINGS OF THE INTERNATIONAL RENEWABLE ENERGY STORAGE AND SYSTEMS CONFERENCE, IRES 2023, 2024, 32 : 195 - 204
  • [47] Simulation and experiment of a photovoltaic-air source heat pump system with thermal energy storage for heating and domestic hot water supply
    Da, Junyu
    Li, Ming
    Li, Guoliang
    Wang, Yunfeng
    Zhang, Ying
    BUILDING SIMULATION, 2023, 16 (10) : 1897 - 1913
  • [48] Performance comparison of sensible and latent heat-based thermal storage system during discharging - an experimental study
    Suresh, C.
    Saini, R. P.
    EXPERIMENTAL HEAT TRANSFER, 2022, 35 (01) : 45 - 61
  • [49] Experimental investigation on enhancement of thermal performance with obstacle placing in the horizontal hot water tank used in solar domestic hot water system
    Erdemir, Dogan
    Atesoglu, Hakan
    Altuntop, Necdet
    RENEWABLE ENERGY, 2019, 138 : 187 - 197
  • [50] Experimental Energy Study for Domestic Hot Water Storage Tanks
    Beithou, N.
    Abu Hilal, M.
    JORDAN JOURNAL OF MECHANICAL AND INDUSTRIAL ENGINEERING, 2011, 5 (05): : 471 - 477