Combined Multichannel Intraluminal Impedance and pH Measurement in Detecting Gastroesophageal Reflux Disease in Children

被引:21
|
作者
Safe, Mark [1 ,2 ]
Cho, Jemma [1 ]
Krishnan, Usha [1 ,2 ]
机构
[1] Univ New South Wales, Sch Womens & Childrens Hlth, Sydney, NSW, Australia
[2] Sydney Childrens Hosp, Dept Pediat Gastroenterol, Sydney, NSW, Australia
关键词
barium meal; esophageal pH monitoring; gastroesophageal reflux; multichannel intraluminal impedance-pH; pediatric; pepsin assay; respiratory aspiration of gastric contents; LARYNGOPHARYNGEAL REFLUX; GASTRIC ASPIRATION; PEDIATRIC-PATIENTS; ESOPHAGEAL PH; PEPSIN; INFANTS; MARKER; ACID; ASSOCIATION; SYMPTOMS;
D O I
10.1097/MPG.0000000000001396
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective:The aim of the study was to evaluate and compare multichannel intraluminal impedance-pH (MII-pH) monitoring with standard investigations including pH testing for detecting gastroesophageal reflux disease (GERD) in children.Methods:A retrospective review of all MII-pH studies performed between July 2007 and March 2013 at Sydney Children's Hospital. Results from MII-pH testing, esophagogastroduodenoscopy (EGD), barium meal and pepsin assay, symptoms, underlying comorbidities, age, and medication usage were evaluated.Results:An additional 47.18% of children had GERD detected by MII-pH testing, which would have been missed by pH testing alone. Based on symptomatology, 50.49% of children with respiratory symptoms as a result of GERD and 47.54% of those with gastrointestinal symptoms would have been missed by pH testing alone. GERD was detected in an additional 39.47% of children with neurological impairment, 44.44% for those with cystic fibrosis, and 52.17% for those with esophageal atresia-tracheoesophageal fistula by MII-pH. In patients with persistent symptoms on anti-reflux medication, GERD would have been missed by pH testing alone in 50.40%. GERD was detected in an additional 62.79% of infants and 42.76% of older children by MII-pH compared with pH testing alone. With reference to MII-pH, the sensitivity of other standard investigations, pH testing (32.35%), barium meal (25.00%), EGD (45.26%), and pepsin assay (48.89%) was significantly lower in the detection of GERD in children. Of all abnormal MII-pH results, 51.1% were abnormal because of symptom association alone.Conclusions:Combined MII-pH testing is superior to standard investigations such as 24-hour pH testing, barium meal, EGD, and pepsin assay in detecting GERD in children, particular because of its ability to associate symptoms with acid and non-acid reflux events.
引用
收藏
页码:E98 / E106
页数:9
相关论文
共 50 条
  • [31] Esophageal combined multichannel intraluminal impedance-pH monitoring and its clinical value in the diagnosis of various types of gastroesophageal reflux disease
    Morozov, S.
    Kukushkina, M.
    Isakov, V.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2012, 24 : 96 - 96
  • [32] GASTROESOPHAGEAL REFLUX DISEASE IN INFANT: RELATIONSHIP BETWEEN MULTICHANNEL INTRALUMINAL IMPEDANCE-PH MONITORING AND CLINICAL OUTCOME
    Cresi, F.
    Locatelli, E.
    Marinaccio, C.
    Grasso, G.
    Castagno, E.
    Silvestro, L.
    PEDIATRIC RESEARCH, 2010, 68 : 142 - 142
  • [33] Multichannel Intraluminal Impedance Measurement of Gastroesophageal Reflux in Patients with Different Stages of Morbid Obesity
    Schneider, Juliane M. E.
    Bruecher, Bjoern L. D. M.
    Kueper, Markus
    Saemann, Kathrin
    Koenigsrainer, Alfred
    Schneider, Joachim H.
    OBESITY SURGERY, 2009, 19 (11) : 1522 - 1529
  • [34] Multichannel Intraluminal Impedance Measurement of Gastroesophageal Reflux in Patients with Different Stages of Morbid Obesity
    Juliane M.E. Schneider
    Björn L.D.M. Brücher
    Markus Küper
    Kathrin Saemann
    Alfred Königsrainer
    Joachim H. Schneider
    Obesity Surgery, 2009, 19 : 1522 - 1529
  • [35] Reproducibility of multichannel intraluminal electrical impedance monitoring of gastroesophageal reflux
    Bredenoord, AJ
    Weusten, BLAM
    Timmer, R
    Smout, AJPM
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2005, 100 (02): : 265 - 269
  • [36] Mean nocturnal baseline impedance, a novel metric of multichannel intraluminal impedance-pH monitoring in diagnosing gastroesophageal reflux disease
    Wu, Yanhong
    Guo, Zihao
    Zhang, Chuan
    Zhan, Yutao
    THERAPEUTIC ADVANCES IN GASTROENTEROLOGY, 2022, 15
  • [37] Combined multichannel intraluminal impedance and pH-metry: An evolving technique to measure type and proximal extent of gastroesophageal reflux
    Castell, DO
    Vela, M
    AMERICAN JOURNAL OF MEDICINE, 2001, 111 : 157 - 159
  • [38] Evaluation of Esophageal Motility Using Multichannel Intraluminal Impedance in Healthy Children and Children With Gastroesophageal Reflux
    Di Pace, Maria Rita
    Caruso, Anna Maria
    Catalano, Pieralba
    Casuccio, Alessandra
    De Grazia, Enrico
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2011, 52 (01): : 26 - 30
  • [39] The Correlation between Endoscopic Reflux Esophagitis and Combined Multichannel Intraluminal Impedance-pH Monitoring in Children
    Liu, Yu-Wen
    Wu, Jia-Feng
    Chen, Huey-Ling
    Hsu, Hong-Yuan
    Chang, Mei-Hwei
    Hsu, Wei-Chung
    Tseng, Ping-Huei
    Wang, Hsiu-Po
    Ni, Yen-Hsuan
    PEDIATRICS AND NEONATOLOGY, 2016, 57 (05): : 385 - 389
  • [40] Combined multi-channel intraluminal impedance measurement and pHmetry in the detection of gastroesophageal reflux disease in children with cystic fibrosis
    Goncalves, Emilia da Silva
    Ribeiro, Jose Dirceu
    Marson, Fernando Augusto Lima
    Montes, Ciro Garcia
    Ribeiro, Antonio Fernando
    Mainz, Jochen Georg
    Toro, Adyleia Aparecida Dalbo Contrera
    Zamariola, Juliana Helena
    Borgli, Daniela Souza Paiva
    Lomazi, Elizete Aparecida
    Servidoni, Maria de Fatima Correa Pimenta
    JORNAL DE PEDIATRIA, 2023, 99 (03) : 269 - 277