Combined Multichannel Intraluminal Impedance and pH Measurement in Detecting Gastroesophageal Reflux Disease in Children

被引:21
|
作者
Safe, Mark [1 ,2 ]
Cho, Jemma [1 ]
Krishnan, Usha [1 ,2 ]
机构
[1] Univ New South Wales, Sch Womens & Childrens Hlth, Sydney, NSW, Australia
[2] Sydney Childrens Hosp, Dept Pediat Gastroenterol, Sydney, NSW, Australia
关键词
barium meal; esophageal pH monitoring; gastroesophageal reflux; multichannel intraluminal impedance-pH; pediatric; pepsin assay; respiratory aspiration of gastric contents; LARYNGOPHARYNGEAL REFLUX; GASTRIC ASPIRATION; PEDIATRIC-PATIENTS; ESOPHAGEAL PH; PEPSIN; INFANTS; MARKER; ACID; ASSOCIATION; SYMPTOMS;
D O I
10.1097/MPG.0000000000001396
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective:The aim of the study was to evaluate and compare multichannel intraluminal impedance-pH (MII-pH) monitoring with standard investigations including pH testing for detecting gastroesophageal reflux disease (GERD) in children.Methods:A retrospective review of all MII-pH studies performed between July 2007 and March 2013 at Sydney Children's Hospital. Results from MII-pH testing, esophagogastroduodenoscopy (EGD), barium meal and pepsin assay, symptoms, underlying comorbidities, age, and medication usage were evaluated.Results:An additional 47.18% of children had GERD detected by MII-pH testing, which would have been missed by pH testing alone. Based on symptomatology, 50.49% of children with respiratory symptoms as a result of GERD and 47.54% of those with gastrointestinal symptoms would have been missed by pH testing alone. GERD was detected in an additional 39.47% of children with neurological impairment, 44.44% for those with cystic fibrosis, and 52.17% for those with esophageal atresia-tracheoesophageal fistula by MII-pH. In patients with persistent symptoms on anti-reflux medication, GERD would have been missed by pH testing alone in 50.40%. GERD was detected in an additional 62.79% of infants and 42.76% of older children by MII-pH compared with pH testing alone. With reference to MII-pH, the sensitivity of other standard investigations, pH testing (32.35%), barium meal (25.00%), EGD (45.26%), and pepsin assay (48.89%) was significantly lower in the detection of GERD in children. Of all abnormal MII-pH results, 51.1% were abnormal because of symptom association alone.Conclusions:Combined MII-pH testing is superior to standard investigations such as 24-hour pH testing, barium meal, EGD, and pepsin assay in detecting GERD in children, particular because of its ability to associate symptoms with acid and non-acid reflux events.
引用
下载
收藏
页码:E98 / E106
页数:9
相关论文
共 50 条
  • [1] The role of combined multichannel intraluminal impedance and pH- monitoring in newborn with gastroesophageal reflux disease
    Cresi, Francesco
    Locatelli, Emanuela
    REVIEWS IN HEALTH CARE, 2010, 1 (01) : 35 - 52
  • [2] Reflux profile of Chinese gastroesophageal reflux disease patients with combined multichannel intraluminal impedance-pH monitoring
    Xiao, Ying L.
    Lin, Jin K.
    Cheung, Ting K.
    Wong, Nina Y. H.
    Hung, Ivan F. N.
    Wong, Benjamin C. Y.
    Peng, Sui
    Wang, An J.
    Chen, Min H.
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2009, 24 (06) : 1113 - 1118
  • [3] Multichannel Intraluminal Impedance and pH Monitoring are Complementary Methods in the Diagnosis of Gastroesophageal Reflux Disease in Children
    Altay, Derya
    Ozkan, Tanju Basarir
    Ozgur, Taner
    Sahin, Nilufer Ulku
    EURASIAN JOURNAL OF MEDICINE, 2022, 54 (01): : 22 - 26
  • [4] Detection of Gastroesophageal Reflux in Children Using Combined Multichannel Intraluminal Impedance and pH Measurement: Data from the German Pediatric Impedance Group
    Pilic, Denisa
    Froehlich, Thorsten
    Noeh, Frank
    Pappas, Angeliki
    Schmidt-Choudhury, Anjona
    Koehler, Henrik
    Skopnik, Heino
    Wenzl, Tobias G.
    JOURNAL OF PEDIATRICS, 2011, 158 (04): : 650 - U163
  • [5] The sensitivity of multichannel intraluminal impedance and the pH probe in the evaluation of gastroesophageal reflux in children
    Rosen, R
    Lord, C
    Nurko, S
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2006, 4 (02) : 167 - 172
  • [6] Combined multichannel intraluminal impedance and pH monitoring assists the diagnosis of sliding hiatal hernia in children with gastroesophageal reflux disease
    Wu, Jia-Feng
    Hsu, Wei-Chung
    Tseng, Ping-Huei
    Wang, Hsiu-Po
    Hsu, Hong-Yuan
    Chang, Mei-Hwei
    Ni, Yen-Hsuan
    JOURNAL OF GASTROENTEROLOGY, 2013, 48 (11) : 1242 - 1248
  • [7] Combined multichannel intraluminal impedance and pH monitoring assists the diagnosis of sliding hiatal hernia in children with gastroesophageal reflux disease
    Jia-Feng Wu
    Wei-Chung Hsu
    Ping-Huei Tseng
    Hsiu-Po Wang
    Hong-Yuan Hsu
    Mei-Hwei Chang
    Yen-Hsuan Ni
    Journal of Gastroenterology, 2013, 48 : 1242 - 1248
  • [8] Does Combined Multichannel Intraluminal Impedance and pH (MII-pH) Testing Improve Clinical Outcomes in Children With Gastroesophageal Reflux Disease?
    Lee, Adrian L. H.
    Varjavandi, Vincent
    Lemberg, Daniel A.
    Ooi, Chee Y.
    Gupta, Nitin
    Krishnan, Usha
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2020, 71 (05): : 596 - 603
  • [9] Detection of gastroesophageal reflux in children with cerebral palsy using combined multichannel intraluminal impedance-ph procedure
    Caltepe, Gonul
    Yuce, Ozlem
    Comba, Atakan
    Ozyurek, Hamit
    Kalayci, Ayhan Gazi
    Tasdemir, Haydar Ali
    TURKISH JOURNAL OF PEDIATRICS, 2016, 58 (05) : 524 - 531
  • [10] Multichannel intraluminal impedance associated with pH-metry in the study of gastroesophageal reflux disease
    San Juan, A. Ruiz de Leon
    de la Serna Bueno, J. A. Perez
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2008, 100 (02) : 67 - 70