A Simplified Equivalent Model for the Analysis of Low-Frequency Stability of Multi-Bus DC Microgrids

被引:50
|
作者
Rashidirad, Nasim [1 ]
Hamzeh, Mohsen [1 ]
Sheshyekani, Keyhan [2 ]
Afjei, Ebrahim [1 ]
机构
[1] Shahid Beheshti Univ, Dept Elect Engn, Tehran 1983963113, Iran
[2] Ecole Polytech Montreal, Montreal, PQ H3C 3A7, Canada
基金
美国国家科学基金会;
关键词
Complex conjugate zeros; droop controller; low-frequency stability; multi-bus microgrid; simplified model; voltage-controlled DGs; LOAD; STABILIZATION; IMPEDANCE; DESIGN;
D O I
10.1109/TSG.2017.2705194
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a simplified equivalent model is proposed to investigate low-frequency (LF) stability of dc microgrids. This is done by using an impedance-based approach considering exact models of microgrid components. In order to apply the impedance-based stability criterion, a multi-bus dc microgrid is first categorized as multiple interconnected single-bus de microgrids. Then, each single-bus system is classified into two subsystems: subsystem#1 which only includes voltage-controlled (VC) DGs and subsystem#2 which includes the rest of the dc microgrid components. It is shown that due to the absence of LF interaction between subsystems, the dominant LF modes of a single-bus dc microgrid are mainly determined by the droop controllers of VC-DGs. The studies also show that the droop controller of each VC-DG accounts for the LF complex conjugate zeros at the output impedance of each VC-DG; and the internal interaction among these zeros can result in LF poles, which are the origin of LF current/power oscillations in dc microgrids. Through further analyses, it is shown that our findings for single-bus dc microgrids can be extended to any multi-bus dc microgrid as well. Owing to this fact, a simplified equivalent model, which can lead to the order reduction of the overall system, is proposed for the analysis of LF stability of de microgrids. Thanks to the simplicity and generality of the proposed equivalent model, the effect of different parameters, such as number of VC-DGs, internal voltage controller of VC-DGs, and the microgrid line impedances on the LF stability of de microgrids is comprehensively investigated. The studies also show that the LF stability of a de microgrid is approximately independent of droop types (current or power). A complete set of simulation studies are provided which further supports the effectiveness of the proposed model.
引用
收藏
页码:6170 / 6182
页数:13
相关论文
共 50 条
  • [11] An Effective Method for Low-Frequency Oscillations Damping in MultiBus DC Microgrids
    Rashidirad, Nasim
    Hamzeh, Mohsen
    Sheshyekani, Keyhan
    Afjei, Ebrahim
    [J]. IEEE JOURNAL ON EMERGING AND SELECTED TOPICS IN CIRCUITS AND SYSTEMS, 2017, 7 (03) : 403 - 412
  • [12] Large-Signal Stability Analysis for DC Microgrids Based on the Improved Equivalent Circuit Model
    Wang L.
    Tan Z.
    Zeng X.
    Zhao B.
    Zheng Y.
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (05): : 1284 - 1299
  • [13] A Novel Small Signal Model of Multi-Bus Microgrids for Modeling Interaction of Droop Controllers through the Power Network
    Eskandari, Mohsen
    Li, Li
    [J]. 2017 20TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2017,
  • [14] A PLL-equivalent model for low-frequency stability analysis of voltage source converter connected to weak grid
    Li, Xialin
    Zhang, Chen
    Zhu, Lin
    Wang, Zhi
    Guo, Li
    [J]. IET ENERGY SYSTEMS INTEGRATION, 2023, 5 (02) : 180 - 191
  • [15] A Multi-Model Methodology for Stability Assessment of Complex DC Microgrids
    Tavagnutti, Andrea Alessia
    Bosich, Daniele
    Sulligoi, Giorgio
    [J]. 2021 IEEE FOURTH INTERNATIONAL CONFERENCE ON DC MICROGRIDS (ICDCM), 2021,
  • [16] AN ANALYSIS OF A LOW-FREQUENCY MODEL OF THE COCHLEA
    HOLMES, MH
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1980, 68 (02): : 482 - 488
  • [17] Multi-Model Control Strategy for DC Bus Regulation of a PISO Converter in Microgrids Applications
    Correa, Carlos A.
    Calleja, Hugo
    Rodriguez, Elias
    Lopez-Nunez, Adolfo R.
    Aguilar-Castillo, Carlos
    [J]. 2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 3386 - 3391
  • [18] A generalized DC model and low-frequency dynamic analysis for the class-D converter at fixed frequency
    Cheng, JH
    Witulski, AL
    Vollin, JL
    Shaw, DL
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (06) : 1212 - 1220
  • [19] A generalized DC model and low-frequency dynamic analysis for the Class-D converter at fixed frequency
    Cheng, JH
    Witulski, AF
    Vollin, JL
    Shaw, DL
    [J]. PESC'97: 28TH ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE - RECORD, VOLS I AND II, 1997, : 217 - 223
  • [20] An equivalent skin conductivity model for low-frequency magnetic field dosimetry
    De Santis, Valerio
    Chen, Xi Lin
    Laakso, Ilkka
    Hirata, Akimasa
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2015, 1 (01):