Valve-in-Valve Transcatheter Aortic Valve Replacement in a High-Risk Patient with a Biocor Bioprosthesis and a Flail Prosthetic Valve Leaflet

被引:0
|
作者
Abela, Oliver [1 ]
Schoeller, Michael [1 ,2 ]
Williams, Parker [1 ]
Lambert, Charles [1 ]
Bloom, Marc [3 ]
机构
[1] AdventHlth Tampa Pepin Heart Inst, Cardiol, 3100 East Fletcher Ave, Tampa, FL 33613 USA
[2] Lincoln Mem Univ, Cardiol, DeBusk Coll Osteopath Med, 6965 Cumberland Gap Pkwy, Harrogate, TN 37752 USA
[3] AdventHlth Tampa Pepin Heart Inst, Cardiothorac Surg, 3100 East Fletcher Ave, Tampa, FL 33613 USA
关键词
Bioprosthetic; TAVR; Regurgitation; HEART-VALVES; PREDICTORS; SURGERY; SOCIETY;
D O I
10.15212/CVIA.2021.0031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
An 80-year-old woman with a history of surgical aortic valve replacement with a 21 mm St. Jude Medical Biocor porcine aortic valve 14 years prior presented with New York Heart Association (NYHA) class III symptoms, severe aortic insufficiency from a degenerated prosthesis, and a large echocardiographic mobile mass representing a highly mobile prosthetic leaflet. The patient worsened to NYHA class IV symptoms despite medical management. The Society of Thoracic Surgery mortality risk score was extremely high. However, a valve-in-valve transcatheter aortic valve replacement (TAVR) was found to be a reasonable option. We used a 20 mm SAPIEN 3 Ultra valve (Edwards Lifesciences Inc., Irvine, CA, USA) with a SENTINEL embolic protection device (Boston Scientific, Marlborough, MA, USA). During valve deployment, the echocardiographic mobile mass was visually pinned between the new TAVR valve and the surgical bioprosthetic valve. No large embolic debris was noted within the embolic protection device, and the patient remained without any new focal neurologic deficits in the perioperative period and at the 30-day follow-up. The severe aortic insufficiency resolved, and the patient clinically improved to NYHA class II symptoms.
引用
收藏
页码:191 / 194
页数:4
相关论文
共 50 条
  • [41] Bioprosthetic aortic valve leaflet disruption with high energy electrocautery to prevent coronary artery obstruction during valve-in-valve transcatheter aortic valve replacement
    Nelson, Bradley C.
    Chadderdon, Scott
    Song, Howard
    Zahr, Firas E.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (01) : 164 - 168
  • [42] Reversible thrombotic aortic valve restenosis after valve-in-valve transcatheter aortic valve replacement
    Goleski, Patrick J.
    Reisman, Mark
    Don, Creighton W.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (01) : 165 - 168
  • [43] Valve-in-Valve Transcatheter Aortic Valve Replacement Following 2 Surgical Aortic Valve Replacements
    Moubarak, Ghadi
    Gupta, Swapnil
    Ladner, Jonathan
    Kluis, Austin
    Banwait, Jasjit
    Dimaio, J. Michael
    Mack, Michael J.
    Szerlip, Molly I.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (11) : E013305
  • [44] Successful Evolut R Valve-in-Valve Transcatheter Aortic Valve Replacement
    Reardon, Michael J.
    Bapat, Vinayak Nilkanth
    Popma, Jeffrey J.
    ANNALS OF THORACIC SURGERY, 2017, 103 (01): : 365 - 366
  • [45] CoreValve bioprosthesis dysfunction treated with a Sapien 3 valve-in-valve transcatheter aortic valve replacement and BASILICA technique
    Sharma, Ravi K.
    Tuttle, Mark K.
    Poulin, Marie-France
    Laham, Roger J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (02) : 403 - 406
  • [46] Valve-in-valve transcatheter aortic valve implantation into a novel, sutureless bioprosthesis: technical considerations
    Andreas, Martin
    Coti, Iuliana
    Laufer, Guenther
    Kastner, Johannes
    EUROINTERVENTION, 2018, 13 (16) : 1902 - 1903
  • [47] Outcomes of Valve-in-Valve Transcatheter Aortic Valve Replacement With and Without Bioprosthetic Valve Fracture
    Brinkmann, Christina
    Schofer, Joachim
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (19) : B9 - B9
  • [48] Bioprosthesis leaflet thrombosis following self-expanding valve-in-valve transcatheter aortic valve replacement in patient taking factor Xa inhibitor and warfarin: A case report
    Buchanan, Kyle D.
    Alraies, M. Chadi
    Weissman, Gaby
    Ben-Dor, Itsik
    Satler, Lowell F.
    Waksman, Ron
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2018, 19 (01) : 29 - 32
  • [49] Valve-in-valve Transcatheter Aortic Valve Replacement in a Patient with Late Failure of a Bioprosthetic Bentall Procedure
    Budassi, Simone
    Verheye, Stefan
    Agostoni, Pierfrancesco
    Zivelonghi, Carlo
    Scott, Benjamin
    Vermeersch, Paul
    STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2020, 4 (03): : 236 - 239
  • [50] Deformation of Transcatheter Heart Valve Following Valve-in-Valve Transcatheter Aortic Valve Replacement Implications for Hemodynamics
    Fukui, Miho
    Sorajja, Paul
    Cavalcante, Joao L.
    Thao, Kiahltone R.
    Okada, Atsushi
    Sato, Hirotomo
    Wang, Cheng
    Koike, Hideki
    Hamid, Nadira
    Enriquez-Sarano, Maurice
    Lesser, John R.
    Bapat, Vinayak N.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (05) : 515 - 526