Practical guidelines for the high-sensitivity detection and monitoring of paroxysmal nocturnal hemoglobinuria clones by flow cytometry

被引:103
|
作者
Sutherland, D. Robert [1 ]
Keeney, Michael [2 ]
Illingworth, Andrea [3 ]
机构
[1] Toronto Gen Hosp, Lab Med Program, Toronto, ON M5G 2C4, Canada
[2] London Lab Serv Grp, London, ON, Canada
[3] Dahl Chase Diagnost Serv, Bangor, ME USA
关键词
high-sensitivity flow cytometry; paroxysmal nocturnal hemoglobinuria; practical guidelines; COMPLEMENT INHIBITOR ECULIZUMAB; PIG-A GENE; DIAGNOSIS; CELLS; PNH; ERYTHROCYTES; DEFICIENCY; PROTEIN; FLAER;
D O I
10.1002/cyto.b.21023
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Paroxysmal nocturnal hemoglobinuria (PNH) is a life-threatening disorder caused by an inability to make glyco-phosphatidyl-inositol (GPI) anchors. While flow cytometry is the method of choice to detect the loss of GPI-linked proteins, the development and validation of sensitive, standardized, methodologies have been hampered by the rarity of this disease and by technical difficulties in the accurate identification of PNH cells. Methods: Guidelines for the diagnosis and monitoring of PNH by flow cytometry were recently published by the International Clinical Cytometry Society (ICCS). However, specific reagent cocktails, and associated detailed analytic strategies were not directly addressed therein. In this supporting document based on the ICCS guidelines, we provide concise practical protocols for the high-sensitivity detection of PNH RBCs and WBCs (both granulocytes and monocytes). Results: The CD235aFITC/CD59PE assay described was capable of detecting as few as 20 Type III PNH RBCs per million cells. Frequencies of Type III PNH cells in 10 normal samples were in the 06 per million RBCs. The high-resolution granulocyte/neutrophil assays described in this study could detect PNH phenotypes consistently at a level of 0.01% sensitivity. Frequencies of PNH phenotypes in normal individuals were in the 010 per million granulocytes/neutrophils range. Conclusions: The careful screening and selection of specific antibody conjugates has allowed the development of reagent cocktails suitable for high-sensitivity flow cytometric detection of PNH RBCs and PNH WBCs. The reagent cocktails described herein can be used on a variety of clinical flow cytometers equipped with four or more photo multiplier tubes. (c) 2012 International Clinical Cytometry Society
引用
收藏
页码:195 / 208
页数:14
相关论文
共 50 条
  • [41] Flow cytometry screening for paroxysmal nocturnal hemoglobinuria: A single-center experience in Saudi Arabia
    AlGhasham, Nahlah
    Abulkhair, Yasmeen
    Khalil, Salem
    [J]. CYTOMETRY PART B-CLINICAL CYTOMETRY, 2015, 88 (06) : 389 - 394
  • [42] DETECTION OF CYTOKINE RECEPTORS BY HIGH-SENSITIVITY IMMUNOFLUORESCENCE FLOW-CYTOMETRY
    ZOLA, H
    FLEGO, L
    SHELDON, A
    [J]. IMMUNOBIOLOGY, 1992, 185 (2-4) : 350 - 365
  • [43] IDENTIFICATION AND MONITORING OF PAROXYSMAL NOCTUNAL HEMOGLOBINURIA CLONES IN HIGH RISK PATIENT GROUPS
    Ciriello, Maria Matilde
    Bensi, Thea
    Cattana, Elena
    Petruzza, Alessandra
    Guaschino, Roberto
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 : 28 - 28
  • [44] Comparison of a dual color flow cytometry (FC) assay and the RedQuant/CellQuant kit for detection of paroxysmal nocturnal hemoglobinuria (PNH) cells
    Stahl, S
    Maciejewski, JP
    Hsi, ED
    [J]. CYTOMETRY PART B-CLINICAL CYTOMETRY, 2005, 68B (01) : 66 - 67
  • [45] Multiparameter FLAER-based flow cytometry for screening of paroxysmal nocturnal hemoglobinuria enhances detection rates in patients with aplastic anemia
    Sachdeva, Man Updesh Singh
    Varma, Neelam
    Chandra, Dinesh
    Bose, Parveen
    Malhotra, Pankaj
    Varma, Subhash
    [J]. ANNALS OF HEMATOLOGY, 2015, 94 (05) : 721 - 728
  • [46] Multiparameter FLAER-based flow cytometry for screening of paroxysmal nocturnal hemoglobinuria enhances detection rates in patients with aplastic anemia
    Man Updesh Singh Sachdeva
    Neelam Varma
    Dinesh Chandra
    Parveen Bose
    Pankaj Malhotra
    Subhash Varma
    [J]. Annals of Hematology, 2015, 94 : 721 - 728
  • [47] Diagnosis of paroxysmal nocturnal hemoglobinuria in peripheral blood and bone marrow with six-color flow cytometry
    Yang, Hai-Su
    Yang, Min
    Li, Xiaoyu
    Tugulea, Sorina
    Dong, Henry
    [J]. BIOMARKERS IN MEDICINE, 2013, 7 (01) : 99 - 111
  • [48] PERFORMANCE CHARACTERISTICS OF CONSENSUAL APPROACHES FOR SMALL AND MINOR PAROXYSMAL NOCTURNAL HEMOGLOBINURIA CLONE DETERMINATION BY FLOW CYTOMETRY
    Marinov, I.
    Kohoutova, M.
    Tkacova, V.
    Pesek, A.
    Cermak, J.
    Cetkovsky, P.
    [J]. HAEMATOLOGICA, 2013, 98 : 575 - 575
  • [49] Evaluation of Paroxysmal Nocturnal Hemoglobinuria Screening by Flow Cytometry Through Multicentric Interlaboratory Comparison in Four Countries
    Debliquis, Agathe
    Wagner-Ballon, Orianne
    Le Garff-Tavernier, Magali
    Fossat, Chantal
    Chatelain, Bernard
    Letestu, Remi
    Drenou, Bernard
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2015, 144 (06) : 858 - 868
  • [50] Performance characteristics of consensus approaches for small and minor paroxysmal nocturnal hemoglobinuria clone determination by flow cytometry
    Marinov, Iuri
    Kohoutova, Martina
    Tkacova, Vlasta
    Pesek, Adam
    Cermak, Jaroslav
    Cetkovsky, Petr
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (11) : 2133 - 2139