PATIENT DOSE ASSESSMENT AND OPTIMISATION OF PELVIC RADIOGRAPHY WITH COMPUTED RADIOGRAPHY SYSTEMS

被引:2
|
作者
Abbeyquaye, D. [1 ,2 ]
Inkoom, S. [1 ,3 ]
Hammond, N. B. [1 ,4 ]
Fletcher, J. J. [1 ,5 ]
Botwe, B. O. [6 ]
机构
[1] Univ Ghana, Sch Nucl & Allied Sci, Dept Med Phys, Atom Energy Campus,POB AE 1, Atomic Energy Accra, Ghana
[2] Koforidua Tech Univ, Fac Hlth & Allied Sci, Dept Biomed Engn Technol, POB KF-981, Koforidua, Ghana
[3] Ghana Atom Energy Commiss, Radiat Protect Inst, Radiat Protect & Consultancy Ctr, POB LG 80, Legon, Ghana
[4] Korle Bu Teaching Hosp, Natl Ctr Radiotherapy & Nucl Med, Dept Nucl Med, POB 77, Accra, Ghana
[5] Univ Dev Studies, Fac Appl Sci, Dept Appl Phys, Navrongo Campus,Upper East Reg,POB TL 1350, Tamale, Ghana
[6] Univ Ghana, Coll Hlth Sci, Sch Biomed & Allied Hlth Sci, Dept Radiog, POB KB143,Korle Bu Campus, Accra, Ghana
关键词
X-RAY EXAMINATIONS; IMAGE QUALITY; PARAMETERS; MANAGEMENT; RADIOLOGY; CHEST;
D O I
10.1093/rpd/ncab111
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Digital radiography systems can reduce radiation dose, this capability was harnessed to explore dose and image quality (IQ) optimisation strategies. Entrance surface dose (ESD), effective dose (ED) and organ doses were determined by the indirect method for patients undergoing pelvic anteroposterior X-ray examinations with computed radiography systems. The IQ of patients' radiographs was assessed in terms of signal-to-noise ratio (SNR). An anthropomorphic phantom was exposed with varying tube potential (kVp), tube current-time product (mAs), and focus-to-detector distance (FDD) to determine phantom-entrance dose for the optimisation studies. SNR of each phantom radiograph was determined. Patients' mean ESD of 2.38 +/- 0.60 mGy, ED of 0.25 +/- 0.07 mSv and SNR of 8.5 +/- 2.2 were obtained. After optimisation, entrance dose was reduced by 29.2% with 5 cm increment in FDD, and 5 kVp reduction in tube potential. kVp and/or mAs reduction with an increment in FDD reduced entrance dose without adversely compromising radiographic-IQ.
引用
收藏
页码:41 / 49
页数:9
相关论文
共 50 条
  • [41] Studies on image quality optimisation in Computed Radiography for weld inspection
    Beckmann, Joerg
    Zscherpel, Uwe
    Ewert, Uwe
    [J]. MATERIALS TESTING-MATERIALS AND COMPONENTS TECHNOLOGY AND APPLICATION, 2008, 50 (10): : 552 - 559
  • [42] AEC set-up optimisation with computed radiography imaging
    Mazzocchi, S
    Belli, G
    Busoni, S
    Gori, C
    Menchi, I
    Salucci, P
    Taddeucci, A
    Zatelli, G
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 169 - 173
  • [43] Flat panel digital radiography compared with storage phosphor computed radiography - Assessment of dose versus image quality in phantom studies
    Fischbach, F
    Ricke, J
    Freund, T
    Werk, M
    Spors, B
    Baumann, C
    Pech, M
    Felix, R
    [J]. INVESTIGATIVE RADIOLOGY, 2002, 37 (11) : 609 - 614
  • [44] Optimisation of patient doses in programmable dental panoramic radiography
    Lecomber, AR
    Downes, SL
    Mokhtari, M
    Faulkner, K
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (02) : 107 - 112
  • [45] PATIENT DOSE MEASUREMENT AND DOSE REDUCTION IN CHEST RADIOGRAPHY
    Milatovic, Aleksandra A.
    Spasic Jokic, Vesna M.
    Jovanovic, Slobodan I.
    [J]. NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2014, 29 (03): : 220 - 225
  • [46] New computed radiography technologies in digital radiography
    Fasbender, R
    Schaetzing, R
    [J]. RADIOLOGE, 2003, 43 (05): : 367 - 373
  • [47] PELVIC LIPOMATOSIS - ITS APPEARANCE ON RADIOGRAPHY AND COMPUTED-TOMOGRAPHY
    HOLD, M
    OLBERT, F
    SCHLEGL, A
    KLUMAIR, J
    FOCHEM, K
    [J]. RADIOLOGE, 1981, 21 (06): : 300 - 302
  • [48] Computed Radiography Dose Measurements of External Radiotherapy Beams
    Aberle, C.
    Kapsch, R.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3383 - 3383
  • [49] THE CONTRAST-DETAIL-DOSE EVALUATION OF IMAGE QUALITY, WITH APPLICATION TO COMPUTED RADIOGRAPHY, COMPUTED-TOMOGRAPHY, AND CONVENTIONAL RADIOGRAPHY
    COHEN, G
    AMTEY, SR
    WAGNER, LK
    KATRAGADDA, C
    FOGEL, S
    HANDEL, SF
    LESTER, RG
    DIBIANCA, FA
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 775 - 775
  • [50] Quality assurance of computed and digital radiography systems
    Walsh, C.
    Gorman, D.
    Byrne, P.
    Larkin, A.
    Dowling, A.
    Malone, J. F.
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 271 - 275