Chromatographic separation and sample preparation in one step for MALDI mass spectrometric analysis of subpicomole amounts of heterogeneous protein samples

被引:24
|
作者
Rusconi, F
Schmitter, JM
Rossier, J
le Maire, M
机构
[1] Ecole Super Phys & Chim Ind Ville Paris, Neurobiol Lab, CNRS, UMR 7637, F-75231 Paris 05, France
[2] Univ Bordeaux 1, Lab Physico & Toxicochim, CNRS, UPRES A5472, F-33405 Talence, France
[3] CEA, Sect Biophys Prot & Membranes, Dept Biol Cellulaire & Mol, F-91191 Gif Sur Yvette, France
[4] Ctr Etud Saclay, CNRS, URA 2096, F-91191 Gif Sur Yvette, France
关键词
D O I
10.1021/ac9801364
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and efficient sample preparation method is described that allows analysis of biopolymer mixtures by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). Very low amounts of complex biopolymer mixtures can be analyzed by MALDI MS without any apparent loss of material and with a substantial gain in time by combining chromatographic separation and sample preparation in a single operation. This micropurification method is based on both the formation of a submicroliter reversed-phase chromatographic bed and the use of matrix-containing eluent solutions. In this way, desalting, matrix mixing, and micropurification of a biological sample could be performed in one step. A proteolytic mixture containing Ca2+ ATPase fragments ranging from similar to 1000 to similar to 30 000 Da, obtained after endoproteinase AspN cleavage of sarcoplasmic reticulum vesicles, was analyzed by MALDI MS. Direct analysis by MALDI MS of this peptidic mixture did not provide any signal for the higher molecular mass species. When our micropurification technique was applied to this sample, successful mass data acquisitions for as low as 150 fmol of the similar to 30 000-Da fragment were performed.
引用
收藏
页码:3046 / 3052
页数:7
相关论文
共 33 条
  • [31] Quality by design optimization of a liquid chromatographic-tandem mass spectrometric method for the simultaneous analysis of structurally heterogeneous pharmaceutical compounds and its application to the rapid screening in wastewater and surface water samples by large volume direct injection
    Renai, Lapo
    Scordo, Cristina Vanessa Agata
    El Ghadraoui, Ayoub
    Santana-Viera, Sergio
    Santana Rodriguez, Jose Juan
    Orlandini, Serena
    Furlanetto, Sandra
    Fibbi, Donatella
    Lambropoulou, Dimitra
    Del Bubba, Massimo
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1649
  • [32] PREPARATION AND MASS-SPECTROMETRIC ANALYSIS OF C-13 OF CO2 DERIVED FROM BREATH, BODY-FLUIDS AND FROM OR PROTEIN-BOUND AMINO-ACIDS IN HUMAN SAMPLES
    SCRIMGEOUR, CM
    SMITH, K
    SOLLY, ME
    WERYK, B
    JOURNAL OF PHYSIOLOGY-LONDON, 1986, 380 : P18 - P18
  • [33] Preparation of 4,4-Dimethyloxazoline and Pyrrolidine Derivatives from Fatty Acid Methyl Esters Using Sodium Borohydride: Mild and Simple One-Pot Derivatization Procedures for a Gas Chromatographic-Mass Spectrometric Analysis of Fatty Acids
    Santalova, Elena A.
    Svetashev, Vasily, I
    NATURAL PRODUCT COMMUNICATIONS, 2022, 17 (10)