Assessment of Regional Xenon Ventilation, Perfusion, and Ventilation-Perfusion Mismatch Using Dual-Energy Computed Tomography in Chronic Obstructive Pulmonary Disease Patients

被引:30
|
作者
Hwang, Hye Jeon [1 ,2 ,3 ]
Seo, Joon Beom [2 ,3 ]
Lee, Sang Min [2 ,3 ]
Kim, Namkug [2 ,3 ]
Oh, Sang Young [2 ,3 ]
Lee, Jae Seung [4 ,5 ]
Lee, Sei Won [4 ,5 ]
Oh, Yeon-Mok [4 ,5 ]
机构
[1] Hallym Univ, Sacred Heart Hosp, Coll Med, Dept Radiol, Anyang, Gyeonggi, South Korea
[2] Univ Ulsan, Coll Med, Dept Radiol, Seoul 138736, South Korea
[3] Univ Ulsan, Coll Med, Res Inst Radiol, Seoul 138736, South Korea
[4] Univ Ulsan, Coll Med, Dept Pulm & Crit Care Med, Seoul 138736, South Korea
[5] Univ Ulsan, Coll Med, Asan Med Ctr, Clin Res Ctr Chron Obstruct Airway Dis, Seoul 138736, South Korea
关键词
ventilation-perfusion imbalance; chronic obstructive pulmonary disease; dual-energy CT; HYPERPOLARIZED HE-3 MRI; AIRWAY-OBSTRUCTION; LUNG PERFUSION; BLOOD-VOLUME; SOURCE CT; EMPHYSEMA; EMBOLISM; QUANTIFICATION; SCINTIGRAPHY; SPECT;
D O I
10.1097/RLI.0000000000000239
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aim of this study was to assess the feasibility of combined xenon-enhanced ventilation (V) and iodine-enhanced perfusion (Q) dual-energy computed tomography (DECT) to evaluate regional V and Q status in patients with chronic obstructive pulmonary disease (COPD). Materials and Methods Combined V and Q DECT imaging was performed in 52 prospectively enrolled male COPD patients. Virtual noncontrast images, V maps, and Q maps were anatomically coregistered with deformable registration and evaluated using in-house software. After normalization of the V and Q values of each pixel, normalized V and Q, V/Q(ratio), and VQ(min) (ie, the smaller of the V and Q in each pixel) maps were generated. For visual analysis, the V/Q(ratio) pattern was determined to be matched, mismatched, or reversed mismatched and compared with the regional disease patternsemphysema with/without bronchial wall thickening, bronchial wall thickening, or normal parenchymain each segment. The mean V, Q, V/Q(ratio), and VQ(min) values and the standard deviation of the V/Q(ratio) (V/Q(SD)) of each patient were quantified and compared with pulmonary function test (PFT) parameters using the Pearson correlation test. Results Segments with normal parenchyma showed a matched V/Q(ratio) pattern, whereas segments with bronchial wall thickening commonly showed a reversed mismatched V/Q(ratio) pattern. In the emphysema areas, the matched, mismatched, and reversed mismatched patterns were mixed without a dominant pattern. In quantitative analysis, the mean V, Q, VQ(min), and V/Q(ratio) values were significantly and positively correlated with PFT parameters (r = 0.290-0.819; P < 0.05). The V/Q(SD) was significantly and negatively correlated with PFT parameters (r = -0.439 to -0.736; P < 0.001). VQ(min) values showed the best correlation with PFT parameters (r = 0.483-0.819; P < 0.001). Conclusions Visual and quantitative assessment of the regional V, Q, V/Q(ratio), and VQ(min) is feasible with combined V and Q DECT imaging and significantly correlate with PFT results in COPD patients. Assessing disease patterns using conventional computed tomography images may not provide correct evaluation of regional V and Q in COPD patients with emphysema.
引用
收藏
页码:306 / 315
页数:10
相关论文
共 50 条
  • [31] Computed tomography scan versus ventilation-perfusion lung scan in the detection of pulmonary embolism
    Cueto, SM
    Cavanaugh, SH
    Benenson, RS
    Redclift, MS
    JOURNAL OF EMERGENCY MEDICINE, 2001, 21 (02): : 155 - 164
  • [32] QUANTIFICATION OF LUNG PERFUSION BLOOD VOLUME AND XENON VENTILATION BY DUAL-ENERGY CT IN PATIENTS WITH COMBINED PULMONARY FIBROSIS AND EMPHYSEMA
    Nakamura, Yasuhiko
    Sugino, Keishi
    Gocho, Kyoko
    Ishida, Fumiaki
    Isobe, Kazutoshi
    Kobayashi, Masahiro
    Shiraga, Nobuyuki
    Homma, Sakae
    RESPIROLOGY, 2013, 18 : 137 - 137
  • [33] Quantitative Assessment of Lung Ventilation-Perfusion Imbalance in Patients with Pulmonary Embolism
    Lazareva, A.
    Stephens, E.
    Enescu, M.
    Bond, S.
    Gooding, M.
    Scuffham, J. W.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S329 - S330
  • [34] Findings in Lung Perfusion and Ventilation-Perfusion Scintigraphy in patients with suspicion of Chronic Thromboembolic Pulmonary Hypertension
    Guzman, G.
    Calderon, M.
    Nieto, L.
    Falgas, M.
    Navarro, P.
    Sangros, M.
    Alvarez, S.
    De la Cueva, L.
    Abos, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S331 - S331
  • [35] Dual Energy Computed Tomography Demonstrated Lung Ventilation/Perfusion Mismatch in a 19-Year-Old Patient With Pulmonary Embolism
    Zhang, Long Jiang
    Zhou, Chang Sheng
    Lu, Guang Ming
    CIRCULATION, 2012, 126 (20) : 2441 - 2443
  • [36] Evaluation of Lung Perfusion With Dual-Energy Computed Tomography in a Chronic Pulmonary Thromboembolism Patient
    Hong, Yoo Jin
    Kim, Young Jin
    Lee, Sak
    Choe, Kyu-Ok
    ANNALS OF THORACIC SURGERY, 2011, 91 (04): : E62 - E62
  • [37] REGIONAL VENTILATION-PERFUSION MISMATCH IN LUNG FIBROSIS - A FALSE POSITIVE PULMONARY-EMBOLISM SCAN
    HUGHES, JMB
    HART, D
    CARR, D
    LAVENDER, JP
    PRIDE, NB
    THORAX, 1987, 42 (03) : 229 - 229
  • [38] VENTILATION-PERFUSION DISTRIBUTIONS AND CENTRAL HEMODYNAMICS IN CHRONIC OBSTRUCTIVE PULMONARY-DISEASE - EFFECTS OF TERBUTALINE ADMINISTRATION
    RINGSTED, CV
    ELIASEN, K
    ANDERSEN, JB
    HESLET, L
    QVIST, J
    CHEST, 1989, 96 (05) : 976 - 983
  • [39] Krypton Ventilation Imaging Using Dual-Energy CT in Chronic Obstructive Pulmonary Disease Patients: Initial Experience
    Hachulla, Anne-Lise
    Pontana, Francois
    Wemeau-Stervinou, Lidwine
    Khung, Suonita
    Faivre, Jean-Baptiste
    Wallaert, Benoit
    Cazaubon, Jean-Francois
    Duhamel, Alain
    Perez, Thierry
    Devos, Patrick
    Remy, Jacques
    Remy-Jardin, Martine
    RADIOLOGY, 2012, 263 (01) : 253 - 259
  • [40] Combined Assessment of Pulmonary Ventilation and Perfusion with Single-Energy Computed Tomography and Image Processing
    Fujita, Yukio
    Kent, Michael
    Wisner, Erik
    Johnson, Lynelle
    Stern, Joshua
    Qi, Lihong
    Boone, John
    Yamamoto, Tokihiro
    ACADEMIC RADIOLOGY, 2021, 28 (05) : 636 - 646