Low-dose computed tomography for axial spondyloarthritis: update on use and limitations

被引:17
|
作者
Lambert, Robert G. W. [1 ]
Hermann, Kay Geert A. [2 ]
Diekhoff, Torsten [2 ]
机构
[1] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB, Canada
[2] Charite Univ Med Berlin, Dept Radiol, Berlin, Germany
关键词
computed tomography; low-dose computed tomography; sacroiliac joint; sacroiliitis; spondyloarthritis; ANKYLOSING-SPONDYLITIS; CT; RADIOGRAPHY; SACROILIITIS; PROGRESSION;
D O I
10.1097/BOR.0000000000000803
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose of reviewRecent developments in low-dose computed tomography (ldCT) have greatly reduced radiation exposure levels. This article reviews what a ldCT is and its use and limitations for imaging axial spondyloarthritis.Recent findingsDetection of structural damage in bone with CT is far superior to radiography and ldCT of the sacroiliac joints (SIJ) can now be done at radiation exposure levels equivalent to, or even less than, conventional radiography. ldCT should be considered a 'first-choice' test for arthritis imaging, and wherever available, SIJ ldCT may completely replace conventional radiography. Radiation exposure in the spine with ldCT is lower than conventional CT. However, it is unclear whether the additional information regarding structural damage changes in the spine provided by ldCT will alter patient management sufficiently often to merit switching from spinal radiography to ldCT in routine clinical practice. In addition, ldCT cannot assess osteitis disease activity for which MRI remains the best test.SummaryldCT of the sacroiliac joints (SIJ) can be done at radiation exposure levels equivalent to, or less than, radiography and ldCT may completely replace SIJ radiography. However, the role of spinal ldCT for spondyloarthritis is not clear and MRI is far superior for detecting disease activity.
引用
收藏
页码:326 / 332
页数:7
相关论文
共 50 条
  • [31] A sinogram denoising algorithm for low-dose computed tomography
    Davood Karimi
    Pierre Deman
    Rabab Ward
    Nancy Ford
    BMC Medical Imaging, 16
  • [32] Low-Dose Cardiovascular Computed Tomography: Where Are the Limits?
    Schoenhagen, Paul
    Thompson, Carla M.
    Halliburton, Sandra S.
    CURRENT CARDIOLOGY REPORTS, 2012, 14 (01) : 17 - 23
  • [33] Lung cancer screening with low-dose computed tomography
    Seijo Maceiras, Luis M.
    MEMO-MAGAZINE OF EUROPEAN MEDICAL ONCOLOGY, 2014, 7 (01) : 6 - 9
  • [34] Lung cancer screening with low-dose computed tomography
    Hartman, TE
    Swensen, SJ
    SEMINARS IN ROENTGENOLOGY, 2003, 38 (01) : 34 - 38
  • [35] Low-dose computed tomography in prior asbestos workers
    Roberts, H.
    LUNG CANCER, 2006, 54 : S3 - S3
  • [36] Lung Cancer Screening With Low-Dose Computed Tomography
    Loebig, Stephanie
    Haegele, Patricia
    Seizer, Peter
    DEUTSCHES ARZTEBLATT INTERNATIONAL, 2023, 120 (41):
  • [37] A sinogram denoising algorithm for low-dose computed tomography
    Karimi, Davood
    Deman, Pierre
    Ward, Rabab
    Ford, Nancy
    BMC MEDICAL IMAGING, 2016, 16
  • [38] Lung cancer screening with low-dose computed tomography
    Luis M. Seijo Maceiras
    memo - Magazine of European Medical Oncology, 2014, 7 (1) : 6 - 9
  • [39] Screening for Lung Cancer With Low-Dose Computed Tomography
    Miller, Anthony B.
    ONCOLOGIST, 2013, 18 (08): : 897 - 899
  • [40] Screening for Lung Cancer With Low-Dose Computed Tomography
    Brodersen, John
    Dirksen, Asger
    Pedersen, Jesper Holst
    ANNALS OF INTERNAL MEDICINE, 2014, 160 (03) : 211 - 212