Non-destructive detection of defects in artificial skin tissue by Optical Coherence Tomography

被引:0
|
作者
Schmitt, Robert [1 ]
Marx, Ulrich [1 ]
Heymer, Andrea [2 ]
Kaufmann, Michaela [2 ]
机构
[1] Fraunhofer Inst Prod Technol IPT, Steinbachstr 17, D-52074 Aachen, Germany
[2] Fraunhofer Inst Interfacial Engn & Biotechnol IGB, D-70569 Stuttgart, Germany
关键词
D O I
暂无
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The application of optical coherence tomography (OCT) in tissue engineering facilities offers great potential for the automated detection of defects or inhomogeneities in tissue products. This non-invasive and non-destructive measurement technique allows the high speed generation of two dimensional cross sections of tissue with micron resolution. By the integration into a tissue production facility, the monitoring and quality control of the products will be possible. This allows the selective exclusion of products with insufficient quality from the production chain. In a first study, OCT tomograms of artificial skin equivalents were acquired and compared with microscopic images of associated histologies. As a result, a well-defined analogy of the obtained images is presented. Hence, OCT provides a powerful measurement technique for detecting defects and inhomogeneities in tissue products.
引用
收藏
页码:227 / +
页数:2
相关论文
共 50 条
  • [31] Non-Destructive Inspection Methods for LEDs Using Real-Time Displaying Optical Coherence Tomography
    Cho, Nam Hyun
    Jung, Unsang
    Kim, Suhwan
    Kim, Jeehyun
    SENSORS, 2012, 12 (08) : 10395 - 10406
  • [32] Non-destructive quantification of pharmaceutical tablet coatings using terahertz pulsed imaging and optical coherence tomography
    Zhong, Shuncong
    Shen, Yao-Chun
    Ho, Louise
    May, Robert K.
    Zeitler, J. Axel
    Evans, Mike
    Taday, Philip F.
    Pepper, Michael
    Rades, Thomas
    Gordon, Keith C.
    Mueller, Ronny
    Kleinebudde, Peter
    OPTICS AND LASERS IN ENGINEERING, 2011, 49 (03) : 361 - 365
  • [33] Multimodal mid-infrared optical coherence tomography and spectroscopy for non-destructive testing and art diagnosis
    Zorin, Ivan
    Kilgus, Jakob
    Su, Rong
    Lendl, Bernhard
    Brandstetter, Markus
    Heise, Bettina
    OPTICS FOR ARTS, ARCHITECTURE, AND ARCHAEOLOGY VII, 2019, 11058
  • [34] Non-Destructive and Real-time Optical Inspection for Lens Size using Swept Source Optical Coherence Tomography
    Jia, Pingping
    Zhao, Hong
    Zhao, Jinlei
    Fang, Meiqi
    Qin, Yuwei
    OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION XI, 2019, 11056
  • [35] Three-dimensional non-destructive optical evaluation of laser-processing performance using optical coherence tomography
    Kim, Youngseop
    Choi, Eun Sco
    Kwak, Wooseop
    Shin, Yongjin
    Jung, Woonggyu
    Ahn, Yeh-Chan
    Chen, Zhongping
    OPTICS AND LASER TECHNOLOGY, 2008, 40 (04): : 625 - 631
  • [36] Non-destructive detection
    David Gevaux
    Nature Physics, 2014, 10 (1) : 6 - 6
  • [37] Validation of artificial defects for Non-destructive testing measurements on a reference structure
    Stefan, Maack
    Salvador, Villalobos
    David, Scott
    INTERNATIONAL CONFERENCE ON CONCRETE REPAIR, REHABILITATION AND RETROFITTING (ICCRRR 2018), 2018, 199
  • [39] Research of non-destructive detection of micro bulk defects in materials
    Zheng, Y
    Jun, C
    Ren, Y
    NONDESTRUCTIVE EVALUATION OF MATERIALS AND COMPOSITES, 1996, 2944 : 37 - 43
  • [40] Non-destructive and non-contact measurement of semiconductor optical waveguide using optical coherence tomography with a visible broadband light source
    Ishida, Kazumasa
    Ozaki, Nobuhiko
    Ohsato, Hirotaka
    Watanabe, Eiichiro
    Ikeda, Naoki
    Sugimoto, Yoshimasa
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2018, 57 (08)