摘要
Increasing building construction thermal resistance has been shown to be an effective traditional way of improving building energy efficiency. In this approach, the opaque building envelope is often deemed to be a static system that keeps the indoor environment isolated from the outdoor environment. More recently, active insulation systems (AIS) have been conceptualized to enable active control over building envelope thermal properties, allowing the thermal resistance to be optimally modulated in response to changing environmental conditions. Dynamically tuning the building thermal performance can lead to increased energy savings, reduced operating costs, and reductions in operational carbon emissions. When paired with thermal mass, AIS can also increase building load flexibility for providing demand response and grid services. Building flexibility can further be improved if the building is also equipped with optimized HVAC system controls. In this configuration, the AIS and HVAC systems can be beneficially coordinated to optimally condition the space based on the desired operational objectives. In this work, we quantify the potential benefits of jointly optimizing AIS and HVAC system controls by applying model predictive control to a detailed whole-building energy model. The example building is an all-electric single-family residential building, satisfying IECC 2012, in Baltimore, MD. To highlight the increase in benefits from jointly optimizing HVAC and dynamic envelope systems, we compare the results to the performance achieved when optimizing HVAC and AIS systems individually. Results showed that the combined optimization of HVAC and AIS control was able to achieve 13% peak demand reduction, while savings 3% energy. This is in contrast to only a 10% peak reduction and 16% increase in energy use for the case with optimized HVAC only. These results ultimately motivate further exploration, integration, and joint optimization of dynamic envelope and HVAC system components.
引用
收藏
页码:132 / 139
页数:8
相关论文
共 50 条
  • [41] Model-Based and Data-Driven HVAC Control Strategies for Residential Demand Response
    Kou, Xiao
    Du, Yan
    Li, Fangxing
    Pulgar-Painemal, Hector
    Zandi, Helia
    Dong, Jin
    Olama, Mohammed M.
    IEEE OPEN ACCESS JOURNAL OF POWER AND ENERGY, 2021, 8 : 186 - 197
  • [42] HVAC control in buildings using neural network
    Abida, A.
    Richter, P.
    JOURNAL OF BUILDING ENGINEERING, 2023, 65
  • [43] Optimization of design and control of HVAC
    Nakahara, N
    ISHVAC 99: 3RD INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOLS 1 AND 2, 1999, : 104 - 116
  • [44] Vision-based estimation of clothing insulation for building control: A case study of residential buildings
    Choi, Haneul
    Na, HooSeung
    Kim, Taehung
    Kim, Taeyeon
    BUILDING AND ENVIRONMENT, 2021, 202
  • [45] Hierarchical Nonlinear MPC for Large Buildings HVAC Optimization
    Rastegarpour, Soroush
    Ferrarini, Luca
    2021 IEEE 17TH INTERNATIONAL CONFERENCE ON AUTOMATION SCIENCE AND ENGINEERING (CASE), 2021, : 2175 - 2180
  • [46] Multiobjective Optimization for PI-based Control Strategies for HVAC Systems in Coaches
    Luisa Delgado, Maria
    Ruz, Mario L.
    Vazquez, Francisco
    Jimenez-Hornero, Jorge E.
    IFAC PAPERSONLINE, 2024, 58 (07): : 156 - 161
  • [47] Optimization of Insulation Thickness of External Walls of Residential Buildings in Hot Summer and Cold Winter Zone of China
    Liu, Xiaojun
    Chen, Xin
    Shahrestani, Mehdi
    SUSTAINABILITY, 2020, 12 (04) : 1 - 21
  • [48] Simultaneous optimization of fuel type and exterior walls insulation attributes for residential buildings using a swarm intelligence
    Moloodpoor, M.
    Mortazavi, A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2022, 19 (04) : 2809 - 2822
  • [49] Multi-Objective Optimization of Insulation Thickness with Respect to On-Site RES Generation in Residential Buildings
    Papadopoulos, Agis M.
    Polychronakis, Konstantinos
    Kyriaki, Elli
    Giama, Effrosyni
    ENERGIES, 2024, 17 (22)
  • [50] Simultaneous optimization of fuel type and exterior walls insulation attributes for residential buildings using a swarm intelligence
    M. Moloodpoor
    A. Mortazavi
    International Journal of Environmental Science and Technology, 2022, 19 : 2809 - 2822