T-plate fixation for unstable proximal clavicula fractures

被引:5
|
作者
Zheng, Yi [1 ]
Yuan, Xin-Hua [1 ]
Yin, Yi-Hong [2 ]
Wang, Wei-Bin [1 ]
Fu, Qing-Song [1 ]
Pang, Qing-Jiang [1 ]
机构
[1] Dept Orthopaed, Ningbo, Zhejiang, Peoples R China
[2] Ningbo Municipal Hosp TCM, Ningbo, Zhejiang, Peoples R China
关键词
Clavicula fracture; Proximal; Sternoclavicular ligament; Plate; Internal fixation; STERNOCLAVICULAR JOINT DISLOCATION; MEDIAL-END; OUTCOMES;
D O I
10.1016/j.aott.2018.11.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The aim of this study was to evaluate the clinical results of T-plate fixation and anterior sternoclavicular ligament repair in proximal clavicle fractures. Methods: Between August 2013 and August 2016, a total 12 patients (10 men and 2 women; mean age: 44.1 +/- 9.1 years (range, 25-59 years)) with unstable proximal clavicle fractures (Throckmorton, type D) were treated with T-type plate fixation, bridging the sternoclavicular joint, and anterior sternoclavicular ligament repair. Average operative time, associated injuries, postoperative complications, postoperative fracture healing time and follow-up time were recorded. The outcomes were evaluated with radiographic assessment, visual analog scale (VAS) pain score and Rockwood SCJ scoring system. All the patients were evaluated on postoperative 3rd, 6th, and 12th months. Results: The average surgery time was 78.0 +/- 8.47 minutes while fracture healing time was 4.51 +/- 0.95 months. According to Rockwood SCJ scoring system, 9 cases (75%) were in excellent, 2 cases (16.7%) in good and 1 case (8.3%) in fair condition at 12 months follow-up. The average Rockwood SCJ score was 7.7 +/- 0.75 preoperatively, 12.7 +/- 0.86 by 3 months, 13.0 +/- 0.73 by 6 months and 13.3 +/- 0.49 by 12 months. The VAS pain score was 7.9 +/- 1.15 (preoperative score), 3.4 +/- 1.52 (3 months follow-up), 3.0 +/- 1.32 (6 months follow-up) and 2.1 +/- 1.07 (12 months follow-up). The VAS and Rockwood SCJ scores were significantly improved postoperatively (p < 0.05). There was no intraoperative complication, while one patient had redislocation of the sternoclavicular joint after implant removal. Conclusion: T-type plate fixation with anterior sternoclavicular ligament repair might be a reliable and effective treatment method in unstable proximal clavicle fractures (type D) with few complications and satisfactory clinical results after 12 months follow-up. (C) 2018 Publishing services by Elsevier B.V. on behalf of Turkish Association of Orthopaedics and Traumatology.
引用
收藏
页码:464 / 468
页数:5
相关论文
共 50 条
  • [21] Locking Plate Fixation of Proximal Humerus Fractures
    Strohm, Peter C.
    Koestler, Wolfgang
    Suedkamp, Norbert P.
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2005, 6 (01): : 8 - 13
  • [22] Locking Plate Fixation for Proximal Humerus Fractures
    Burke, Neil G.
    Kennedy, Jim
    Green, Connor
    Dodds, Michael K.
    Mullett, Hannan
    ORTHOPEDICS, 2012, 35 (02) : E250 - E254
  • [23] A new locking plate for unstable fractures of the proximal humerus
    Fankhauser, F
    Boldin, C
    Schippinger, G
    Haunschmid, C
    Szyszkowitz, R
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) : 176 - 181
  • [24] Internal fixation of unstable proximal humerus fractures with an anatomically preshaped interlocking plate:: A clinical and radialogic evaluation
    Hirschmann, Michael Tobias
    Quarz, Volker
    Audige, Laurent
    Ludin, Dietmar
    Messmer, Peter
    Regazzoni, Pietro
    Gross, Thomas
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 63 (06): : 1314 - 1323
  • [25] Locking T-Plate Repair of Ilial Fractures in Cats and Small Dogs
    Scrimgeour, Andrew B.
    Craig, Andrew
    Witte, Philip G.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2017, 30 (06) : 453 - 460
  • [26] Percutaneous Fixation of Unstable Proximal Phalanx Fractures: A Biomechanical Study
    Nikci, Valdet
    Effiong, Linda
    Freibott, Christina E.
    Gardner, Thomas R.
    Strauch, Robert J.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2023, 18 (02): : 282 - 287
  • [27] Closed management and percutaneous fixation of unstable proximal humerus fractures
    Chen, CY
    Chao, EK
    Tu, YK
    Ueng, SWN
    Shih, CH
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1998, 45 (06): : 1039 - 1045
  • [28] The plate fixation strategy of complex proximal humeral fractures
    Qi Sun
    Xiaoming Wu
    Lei Wang
    Ming Cai
    International Orthopaedics, 2020, 44 : 1785 - 1795
  • [29] T-plate osteosynthesis - An obsolete osteosynthesis procedure for proximal humeral fractures? Middle-term clinical and radiological results
    Bahrs, C.
    Oehm, J.
    Rolauffs, B.
    Eingartner, C.
    Weise, K.
    Dietz, K.
    Helwig, P.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2007, 145 (02): : 186 - 194
  • [30] Fixation of proximal humerus fractures using the PHILOS plate
    Koukakis, Athanasios
    Apostolou, Constantinos D.
    Taneja, Tarun
    Korres, Dimitrios S.
    Amini, Alexander
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (442) : 115 - 120