Absolute cryogenic radiometer for high-current photometric measurements

被引:0
|
作者
Goloborodko, VT
Gurev, NV
机构
关键词
D O I
10.1007/BF02375386
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A cryogenic radiometer with electrical substitution has been developed for precise photometric measurements. The radiometer design and specifications are described. The radiometer has an accuracy of 0.02%. It main use is to calibrate the spectral response of reference radiometers.
引用
收藏
页码:1104 / 1109
页数:6
相关论文
共 50 条
  • [41] BEAM MEASUREMENTS ON THE ELECTRON INJECTOR FOR A HIGH-CURRENT BETATRON
    ZIEHER, KW
    FISHBINE, B
    HUMPHRIES, S
    WOODALL, DM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (05) : 3274 - 3276
  • [42] EXPERIMENTAL MEASUREMENTS ON HIGH-CURRENT RELATIVISTIC ELECTRON BEAMS
    ANDREWS, ML
    BZURA, JJ
    DAVITIAN, HE
    FLEISCHM.HH
    HAMMER, DA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (11): : 1572 - &
  • [43] Study for emittance measurements in a high-current multibeamlet beam
    Sartori E.
    Zaupa M.
    Serianni G.
    Pasqualotto R.
    Plasma and Fusion Research, 2018, 13
  • [44] A flexible high-current lead for use in high-magnetic-field cryogenic environments
    Kirkpatrick, PE
    Ekin, JW
    Bray, SL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (08): : 3338 - 3340
  • [45] ABSOLUTE SPECTRORADIOMETRIC AND PHOTOMETRIC SCALES BASED ON AN ELECTRICALLY CALIBRATED PYROELECTRIC RADIOMETER
    CARRERAS, C
    CORRONS, A
    APPLIED OPTICS, 1981, 20 (07): : 1174 - 1177
  • [46] Long-Wave Infrared Absolute Spectral Responsivity Scale by Using an Absolute Cryogenic Radiometer
    Liu Hong-bo
    Shi Xue-shun
    Xu Wen-bin
    Liu Chang-ming
    Liu Hong-yuani
    Wang Heng-fei
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (12) : 3680 - 3685
  • [47] Prototype of Cryogenic Solar Absolute Radiometer and Transfer Radiometer for On-Board Calibration of Spectral Earth Imager
    Zajiczek, L.
    Winkler, R.
    Hobson, T.
    Green, P.
    Fox, N.
    13TH INTERNATIONAL CONFERENCE ON NEW DEVELOPMENTS AND APPLICATIONS IN OPTICAL RADIOMETRY, 2018, 972
  • [48] Film radiometer based on electrical substitution for use in photometric measurements
    Goloborod'ko, VT
    Gritsai, VV
    Gur'ev, NV
    Tsypko, NK
    MEASUREMENT TECHNIQUES, 1997, 40 (05) : 428 - 432
  • [49] Film radiometer based on electrical substitution for use in photometric measurements
    V. T. Goloborod'ko
    V. V. Gritsai
    N. V. Gur'ev
    N. K. Tsypko
    Measurement Techniques, 1997, 40 : 428 - 432
  • [50] On measurements of the basic parameters of high-current relativistic electron beams
    Fuks, MI
    Goikhman, MB
    Kovalev, NF
    Palitsin, AV
    Schamiloglu, E
    BEAMS 2002, 2002, 650 : 235 - 238