Absolute cryogenic radiometer for high-current photometric measurements

被引:0
|
作者
Goloborodko, VT
Gurev, NV
机构
关键词
D O I
10.1007/BF02375386
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A cryogenic radiometer with electrical substitution has been developed for precise photometric measurements. The radiometer design and specifications are described. The radiometer has an accuracy of 0.02%. It main use is to calibrate the spectral response of reference radiometers.
引用
收藏
页码:1104 / 1109
页数:6
相关论文
共 50 条
  • [1] A CRYOGENIC RADIOMETER FOR ABSOLUTE RADIOMETRIC MEASUREMENTS
    MARTIN, JE
    FOX, NP
    KEY, PJ
    METROLOGIA, 1985, 21 (03) : 147 - 155
  • [2] Direct Solar Irradiance Measurements with a Cryogenic Solar Absolute Radiometer
    Walter, Benjamin
    Winkler, Rainer
    Graber, Florian
    Finsterle, Wolfgang
    Fox, Nigel
    Li, Vivian
    Schmutz, Werner
    RADIATION PROCESSES IN THE ATMOSPHERE AND OCEAN, 2017, 1810
  • [3] Space Cryogenic Absolute Radiometer
    Wu D.
    Wang K.
    Ye X.
    Wang Y.-P.
    Fang W.
    Faguang Xuebao/Chinese Journal of Luminescence, 2019, 40 (08): : 1015 - 1021
  • [4] Spectrally integrated window transmittance measurements for a cryogenic solar absolute radiometer
    Walter, Benjamin
    Fehlmann, Andre
    Finsterle, Wolfgang
    Suter, Markus
    Soder, Ricco
    Schmutz, Werner
    METROLOGIA, 2014, 51 (06) : S344 - S349
  • [5] Experimental Study on Traceability of Absolute Radiometer to Cryogenic Radiometer
    Zhang Junchao
    Xu Nan
    Xu Ning
    Meng Haifeng
    Liu Wende
    Cai Chuan
    Zhang Bifeng
    Man Shuai
    Wang Meng
    Li Yinliang
    Xiong Limin
    ACTA OPTICA SINICA, 2022, 42 (05)
  • [6] CRYOGENIC SOLAR ABSOLUTE RADIOMETER (CSAR)
    MARTIN, JE
    FOX, NP
    METROLOGIA, 1993, 30 (04) : 305 - 308
  • [7] CHARACTERIZATION OF AN ABSOLUTE CRYOGENIC RADIOMETER AS A STANDARD DETECTOR FOR RADIANT-POWER MEASUREMENTS
    DATLA, RU
    STOCK, K
    PARR, AC
    HOYT, CC
    MILLER, PJ
    FOUKAL, PV
    APPLIED OPTICS, 1992, 31 (34): : 7219 - 7225
  • [8] A cryogenic radiometer for absolute neutron rate measurement
    Chowdhuri, Z
    Hansen, GL
    Jane, V
    Keith, CD
    Lozowski, WM
    Snow, WM
    Dewey, MS
    Gilliam, DM
    Greene, GL
    Nico, JS
    Thompson, AK
    Wietfeldtd, FE
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (10): : 4280 - 4293
  • [9] Filter radiometer based realization of photometric scale traceable to cryogenic radiometer at UME
    Durak, M
    Samedov, F
    Optical Measurement Systems for Industrial Inspection IV, Pts 1 and 2, 2005, 5856 : 972 - 979
  • [10] Total and spectral radiance measurements of blackbody radiation sources based on an absolute cryogenic radiometer
    Gan, Haiyong
    Xu, Nan
    Liu, Xiangliang
    He, Yingwei
    Wu, Houping
    Feng, Guojin
    Liu, Wende
    Lin, Yandong
    AOPC 2019: OPTICAL SENSING AND IMAGING TECHNOLOGY, 2019, 11338