Transcutaneous monitoring of carbon dioxide tension after cardiothoracic surgery in infants and children

被引:37
|
作者
Tobias, JD
Wilson, WR
Meyer, DJ
机构
[1] Univ Missouri, Hlth Sci Ctr, Dept Child Hlth, Columbia, MO 65212 USA
[2] Univ Missouri, Dept Anesthesiol, Columbia, MO 65212 USA
[3] Univ Missouri, Dept Surg, Columbia, MO 65212 USA
[4] Univ Missouri, Div Pediat Crit Care Pediat Anesthesiol, Columbia, MO 65212 USA
[5] Univ Missouri, Div Pediat Cardiothorac Surg, Columbia, MO 65212 USA
来源
ANESTHESIA AND ANALGESIA | 1999年 / 88卷 / 03期
关键词
D O I
10.1097/00000539-199903000-00012
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
In this prospective investigation, we evaluated the efficacy and accuracy of transcutaneous monitoring of CO2 (TC-CO2) in infants and children after cardiothoracic surgery. Cardiothoracic surgery patients whose ETCO2 and arterial CO2 values did not correlate (gradient greater than or equal to 5 mm Hg) during the first postoperative hour underwent placement of the TC electrode (30 of 33 patients). If the TC-CO2 to arterial difference was greater than or equal to 5 mm Hg,the TC-CO2 electrode was recalibrated and reapplied on another site. If the discrepancy was still greater than or equal to 5 mm Hg, the case was considered a clinical failure and no further data were collected (3 of 30 patients). If the arterial to TC gradient was <5 mm Hg, the patient was included in the data collection (27 of 30 patients). One to five sample sets (TC and arterial CO2) were collected from these patients. Statistical analysis included linear regression analysis and Bland-Altman analysis. The cohort for the study included 27 patients ranging in age from 2 days to 9 yr and in weight from 3.2 to 25 kg. A total of 101 sample sets were analyzed. The mean +/- SD absolute difference between the TC-CO2 and arterial CO2 was 1.7 +/- 1.4 mm Hg (range 0-9 mm Hg). The TC-CO2 to arterial CO2 difference was 0-2 mm Hg in 82 of 101 values (81%), 3-5 mm Hg in 18 of 101 values (18%), and >6 mm Hg in 1 of 101 values (1%). Linear regression analysis revealed a slope of 0.90, an r value of 0.9410, and an r(2) value of 0.8854 (P < 0.0001). Bland-Altman analysis revealed a bias of 0.58 mm Hg with a precision of +/-2.1 nam Hg when comparing the TC-CO2 with the arterial CO2. Implications: We conclude that, with certain caveats in mind, including the need to correlate the transcutaneous CO2 with an initial arterial CO2 value, transcutaneous CO2 monitoring can be used to estimate arterial CO2 in most neonates and children after cardiothoracic surgery.
引用
收藏
页码:531 / 534
页数:4
相关论文
共 50 条
  • [31] Transcutaneous Carbon Dioxide Monitoring During Fiberoptic Bronchoscopy
    Sakata, K. K.
    Yaqub, K.
    Vaszar, L. T.
    Lyng, P.
    Parish, J.
    Viggiano, R. W.
    Wesselius, L.
    Swanson, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [32] Accuracy of transcutaneous carbon dioxide monitoring in hypotensive patients
    Kim, Jung-Youn
    Yoon, Young-Hoon
    Lee, Sung-Woo
    Choi, Sung-Hyuk
    Cho, Young-Duck
    Park, Sang-Min
    EMERGENCY MEDICINE JOURNAL, 2014, 31 (04) : 323 - 326
  • [33] Limitations of transcutaneous carbon dioxide monitoring in apneic oxygenation
    Schweizer, Thilo
    Hartwich, Volker
    Riva, Thomas
    Kaiser, Heiko
    Theiler, Lorenz
    Greif, Robert
    Nabecker, Sabine
    PLOS ONE, 2023, 18 (06):
  • [34] Recent Technologies for Transcutaneous Oxygen and Carbon Dioxide Monitoring
    Bernasconi, Sara
    Angelucci, Alessandra
    De Cesari, Anastasia
    Masotti, Aurora
    Pandocchi, Maurizio
    Vacca, Francesca
    Zhao, Xin
    Paganelli, Chiara
    Aliverti, Andrea
    DIAGNOSTICS, 2024, 14 (08)
  • [35] Noninvasive monitoring of carbon dioxide: End-tidal versus transcutaneous carbon dioxide
    Grenier, B
    Dubreuil, M
    ANESTHESIA AND ANALGESIA, 1998, 86 (03): : 675 - 676
  • [36] Monitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport
    Tingay, DG
    Stewart, MJ
    Morley, CJ
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2005, 90 (06): : F523 - F526
  • [37] Transcutaneous Carbon Dioxide Monitoring with Reduced-Temperature Probes in Very Low Birth Weight Infants
    Aly, Safwat
    Ei-Dib, Mohamed
    Mohamed, Mohamed
    Aly, Hany
    AMERICAN JOURNAL OF PERINATOLOGY, 2017, 34 (05) : 480 - 485
  • [38] Potential role of transcutaneous carbon dioxide monitoring in nonintubated video-assisted thoracic surgery
    Li, Tzu-Ying
    Tse, Jockey
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2021, 84 (02) : 242 - 242
  • [39] Postoperative chylothorax after cardiothoracic surgery in children
    Chan, EH
    Russell, JL
    Williams, WG
    Van Arsdell, GS
    Coles, JG
    McCrindle, BW
    ANNALS OF THORACIC SURGERY, 2005, 80 (05): : 1864 - 1871
  • [40] Validation of the transcutaneous carbon dioxide tension measurements in critical paediatric patients
    Fernandez de Miguel, S.
    Gaboli, M.
    Gonzalez-Celador, R.
    Gomez de Quero, P.
    Murga Herrero, V.
    Sanchez Granados, J. M.
    Payo Perez, R.
    ANALES DE PEDIATRIA, 2010, 72 (03): : 165 - 171