Determination of trace palladium in complicated matrices by displacement dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry

被引:21
|
作者
Liang, Pei [1 ]
Zhao, Ehong [1 ]
机构
[1] Cent China Normal Univ, Coll Chem, Key Lab Pesticide & Chem Biol, Minist Educ, Wuhan 430079, Peoples R China
关键词
Displacement dispersive liquid-liquid microextraction; Palladium; Graphite furnace atomic absorption spectrometry; Environmental samples; CLOUD-POINT EXTRACTION; SORPTION PRECONCENTRATION; SPECTROPHOTOMETRIC DETERMINATION; WATER SAMPLES; HEALTH-RISK; SEPARATION; PLATINUM; MERCURY; COPPER;
D O I
10.1007/s00604-011-0611-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We describe a method for displacement dispersive liquid-liquid microextraction (DLLME) along with graphite furnace atomic absorption spectrometry for the determination of Pd(II) in complex environmental samples. In this method, Cu(II) is first complexed with diethyldithiocarbamate (DDTC), and the resultant Cu-DDTC complex added to a sedimented phase and submitted to DLLME. In the second step, the sedimented phase is dispersed into the sample solution containing Pd, and another DLLME procedure is carried out. The Pd ions can displace Cu ions from the pre-extracted Cu-DDTC complex because the stability of the Pd-DDTC complex is higher than that of Cu-DDTC. As a result, Pd is preconcentrated. Potential interferences by transition metal ions of lower complex stability can be largely reduced as they cannot displace Cu from the Cu-DDTC complex. The tolerance limits for such ions are better by 2 to 4 orders of magnitude compared to conventional DLLME. The typical sample volume is 5 mL, and an enhancement factor of 96 and a detection limit (3 s) of 7.6 ng L-1 are achieved.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 50 条
  • [21] One-step displacement dispersive liquid-liquid microextraction coupled with graphite furnace atomic absorption spectrometry for the selective determination of methylmercury in environmental samples
    Liang, Pei
    Kang, Caiyan
    Mo, Yajun
    TALANTA, 2016, 149 : 1 - 5
  • [22] Displacement-Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop of Trace Amounts of Palladium in Water and Road Dust Samples Prior to Graphite Furnace Atomic Absorption Spectrometry Determination
    Ghanbarian, Maryam
    Afzali, Daryoush
    Mostafavi, Ali
    Fathirad, Fariba
    JOURNAL OF AOAC INTERNATIONAL, 2013, 96 (04) : 880 - 886
  • [23] Speciation of As(III) and As(V) in water samples by dispersive liquid-liquid microextraction separation and determination by graphite furnace atomic absorption spectrometry
    Pei Liang
    Lili Peng
    Ping Yan
    Microchimica Acta, 2009, 166 : 47 - 52
  • [24] Determination of Ultra-Trace Amounts of Copper in Environmental Water Samples by Dispersive Liquid-Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry
    Han, Quan
    Yang, Xiaohui
    Huo, Yanyan
    Lu, Jiale
    Liu, Yaqi
    SEPARATIONS, 2023, 10 (02)
  • [25] Trace determination of lead in lipsticks and hair dyes using microwave-assisted dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry
    Sharafi, K.
    Fattahi, N.
    Pirsaheb, M.
    Yarmohamadi, H.
    Davil, M. Fazlzadeh
    INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, 2015, 37 (05) : 489 - 495
  • [26] Speciation of As(III) and As(V) in water samples by dispersive liquid-liquid microextraction separation and determination by graphite furnace atomic absorption spectrometry
    Liang, Pei
    Peng, Lili
    Yan, Ping
    MICROCHIMICA ACTA, 2009, 166 (1-2) : 47 - 52
  • [27] Determination of Cadmium and Lead in Human Teeth Samples Using Dispersive Liquid-liquid Microextraction and Graphite Furnace Atomic Absorption Spectrometry
    Zhang, Chunyan
    Wang, Yining
    Cheng, Xiangrong
    Xia, Haibin
    Liang, Pei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2011, 58 (07) : 919 - 924
  • [28] Trace level enrichment of lead from environmental water samples utilizing dispersive liquid-liquid microextraction and quantitative determination by graphite furnace atomic absorption spectrometry
    Teju, Endale
    Tadesse, Bezuayehu
    Megersa, Negussie
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2014, 49 (07): : 833 - 842
  • [29] Determination of silver(I) ion in water samples by graphite furnace atomic absorption spectrometry after preconcentration with dispersive liquid-liquid microextraction
    Pei Liang
    Lili Peng
    Microchimica Acta, 2010, 168 : 45 - 50
  • [30] Determination of silver(I) ion in water samples by graphite furnace atomic absorption spectrometry after preconcentration with dispersive liquid-liquid microextraction
    Liang, Pei
    Peng, Lili
    MICROCHIMICA ACTA, 2010, 168 (1-2) : 45 - 50