Heat transfer measurement in a three-phase spray column direct contact heat exchanger for utilisation in energy recovery from low-grade sources

被引:23
|
作者
Baqir, Ali Sh. [1 ]
Mahood, Hameed B. [2 ]
Hameed, Mudher S. [2 ]
Campbell, Alasdair N. [3 ]
机构
[1] Al Furat Al Awsat Tech Univ, Al Najaf Engn Tech Coll, Dept Aeronaut Engn, Al Najaf, Iran
[2] Univ Misan, Misan, Iraq
[3] Univ Surrey, Dept Chem & Proc Engn, Guildford, Surrey, England
关键词
Spray column three-phase direct contact heat exchanger; Local volumetric heat transfer coefficient; Active height; Sparger configuration; TRANSFER COEFFICIENT; IMMISCIBLE LIQUID; N-PENTANE; CONDENSER; PREDICTION; PHASE; WATER; MODEL; VAPORIZATION; TEMPERATURE;
D O I
10.1016/j.enconman.2016.08.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy recovery from low-grade energy resources requires an efficient thermal conversion system to be economically viable. The use of a liquid-liquid-vapour direct contact heat exchanger in such processes could be suitable due to their high thermal efficiency and low cost in comparison to a surface type heat exchanger. In this paper, the local volumetric heat transfer coefficient (U-v) and the active height (H-v) of a spray column three-phase direct contact heat exchanger (evaporator) have been investigated experimentally. The heat exchanger comprised a cylindrical Perspex tube of 100 cm height and 10 cm diameter. Liquid pentane at its saturation temperature and warm water at 45 degrees C were used as the dispersed phase and the continuous phase respectively. Three different dispersed phase flow rates (10, 15 and 20 L/h) and four different continuous phase flow rates (10, 20, 30 and 40 L/h) were used throughout the experiments. In addition, three different sparger configurations (7, 19 and 36 nozzles) with two different nozzle diameters (1 and 1.25 mm) were tested. The results showed that the local volumetric heat transfer coefficient (U-v) along the column decreases with height. An increase in both the continuous and dispersed phase flow rates had a positive effect on U-v, while an increase in the number of nozzles in the sparger caused U-v to decrease. The active height was significantly affected by the dispersed and continuous phase flow rates, the sparger configuration and the temperature driving force in terms of the Jacob number. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:342 / 351
页数:10
相关论文
共 41 条
  • [21] An experimental investigation on the performance of TEGs with a compact heat exchanger design towards low-grade thermal energy recovery
    Yang, Wei
    Xie, Heping
    Sun, Licheng
    Ju, Cheng
    Li, Bixiong
    Li, Cunbao
    Zhang, Hongyin
    Liu, Hongtao
    Applied Thermal Engineering, 2021, 194
  • [22] Recovery of Low-Grade Heat (Heat Waste) from a Cogeneration Unit for Woodchips Drying: Energy and Economic Analyses
    Dahou, Tilia
    Dutournie, Patrick
    Limousy, Lionel
    Bennici, Simona
    Perea, Nicolas
    ENERGIES, 2019, 12 (03):
  • [23] Thermionic emission via a nanofluid for direct electrification from low-grade heat energy
    Nguyen, Hoang M.
    Lu, Jian
    Goto, Hiroshi
    Maeda, Ryutaro
    NANO ENERGY, 2018, 49 : 172 - 178
  • [25] The phase separation concept condensation heat transfer in horizontal tubes for low-grade energy utilization
    Xie, Jian
    Xu, Jinliang
    Xing, Feng
    Wang, Zixuan
    Liu, Huan
    ENERGY, 2014, 69 : 787 - 800
  • [27] Heat transfer characteristics of a thermoelectric power generator system for low-grade waste heat recovery from the sugar industry
    Punin, Weera
    Maneewan, Somchai
    Punlek, Chantana
    HEAT AND MASS TRANSFER, 2019, 55 (04) : 979 - 991
  • [28] Heat transfer characteristics of a thermoelectric power generator system for low-grade waste heat recovery from the sugar industry
    Weera Punin
    Somchai Maneewan
    Chantana Punlek
    Heat and Mass Transfer, 2019, 55 : 979 - 991
  • [29] Experimental measurements and theoretical prediction for the volumetric heat transfer coefficient of a three-phase direct contact condenser
    Mahood, Hameed B.
    Campbell, Alasdair N.
    Thorpe, Rex. B.
    Sharif, Ade O.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2015, 66 : 180 - 188
  • [30] An experimental study on the performance of TEGs using uniform flow distribution heat exchanger for low-grade thermal energy recovery
    Lan, Yuncheng
    Lu, Junhui
    Wang, Suilin
    ENERGY, 2024, 292