Heat transfer measurement in a three-phase spray column direct contact heat exchanger for utilisation in energy recovery from low-grade sources

被引:23
|
作者
Baqir, Ali Sh. [1 ]
Mahood, Hameed B. [2 ]
Hameed, Mudher S. [2 ]
Campbell, Alasdair N. [3 ]
机构
[1] Al Furat Al Awsat Tech Univ, Al Najaf Engn Tech Coll, Dept Aeronaut Engn, Al Najaf, Iran
[2] Univ Misan, Misan, Iraq
[3] Univ Surrey, Dept Chem & Proc Engn, Guildford, Surrey, England
关键词
Spray column three-phase direct contact heat exchanger; Local volumetric heat transfer coefficient; Active height; Sparger configuration; TRANSFER COEFFICIENT; IMMISCIBLE LIQUID; N-PENTANE; CONDENSER; PREDICTION; PHASE; WATER; MODEL; VAPORIZATION; TEMPERATURE;
D O I
10.1016/j.enconman.2016.08.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy recovery from low-grade energy resources requires an efficient thermal conversion system to be economically viable. The use of a liquid-liquid-vapour direct contact heat exchanger in such processes could be suitable due to their high thermal efficiency and low cost in comparison to a surface type heat exchanger. In this paper, the local volumetric heat transfer coefficient (U-v) and the active height (H-v) of a spray column three-phase direct contact heat exchanger (evaporator) have been investigated experimentally. The heat exchanger comprised a cylindrical Perspex tube of 100 cm height and 10 cm diameter. Liquid pentane at its saturation temperature and warm water at 45 degrees C were used as the dispersed phase and the continuous phase respectively. Three different dispersed phase flow rates (10, 15 and 20 L/h) and four different continuous phase flow rates (10, 20, 30 and 40 L/h) were used throughout the experiments. In addition, three different sparger configurations (7, 19 and 36 nozzles) with two different nozzle diameters (1 and 1.25 mm) were tested. The results showed that the local volumetric heat transfer coefficient (U-v) along the column decreases with height. An increase in both the continuous and dispersed phase flow rates had a positive effect on U-v, while an increase in the number of nozzles in the sparger caused U-v to decrease. The active height was significantly affected by the dispersed and continuous phase flow rates, the sparger configuration and the temperature driving force in terms of the Jacob number. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:342 / 351
页数:10
相关论文
共 41 条
  • [1] Heat transfer efficiency and capital cost evaluation of a three-phase direct contact heat exchanger for the utilisation of low-grade energy sources
    Mahood, Hameed B.
    Campbell, Alasdair N.
    Thorpe, Rex B.
    Sharif, Adel O.
    ENERGY CONVERSION AND MANAGEMENT, 2015, 106 : 101 - 109
  • [2] Performance of a Three-Phase, Spray-Column, Direct-Contact Heat Exchanger
    Coban, T.
    Boehm, R.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1989, 111 (1-4): : 166 - 172
  • [3] A numerical study on heat transfer characteristics in a spray column direct contact heat exchanger
    Yong Heack Kang
    Nam Jin Kim
    Byung Ki Hur
    Chong Bo Kim
    KSME International Journal, 2002, 16 : 344 - 353
  • [4] A numerical study on heat transfer characteristics in a spray column direct contact heat exchanger
    Kang, YH
    Kim, NJ
    Hur, BK
    Kim, CB
    KSME INTERNATIONAL JOURNAL, 2002, 16 (03): : 344 - 353
  • [5] DIRECT CONTACT HEAT TRANSFER WITH CHANGE OF PHASE - SPRAY-COLUMN STUDIES OF A 3-PHASE HEAT EXCHANGER
    SIDEMAN, S
    GAT, Y
    AICHE JOURNAL, 1966, 12 (02) : 296 - &
  • [6] Convective heat transfer measurements in a vapour-liquid-liquid three-phase direct contact heat exchanger
    Mahood, Hameed B.
    Campbell, A. N.
    Baqir, Ali Sh.
    Sharif, A. O.
    Thorpe, R. B.
    HEAT AND MASS TRANSFER, 2018, 54 (06) : 1697 - 1705
  • [7] Convective heat transfer measurements in a vapour-liquid-liquid three-phase direct contact heat exchanger
    Hameed B. Mahood
    A. N. Campbell
    Ali Sh. Baqir
    A. O. Sharif
    R. B. Thorpe
    Heat and Mass Transfer, 2018, 54 : 1697 - 1705
  • [8] An experimental study of a three-phase, direct-contact heat exchanger
    Siqueiros, J
    Bonilla, O
    APPLIED THERMAL ENGINEERING, 1999, 19 (05) : 477 - 493
  • [9] Maximum possible efficiency for energy recovery from low-grade heat sources
    Gellender, Martin
    INTERNATIONAL JOURNAL OF EXERGY, 2011, 9 (02) : 235 - 253
  • [10] Heat transfer in gas-liquid-liquid three-phase direct-contact exchanger
    Zhang, P
    Wang, YP
    Guo, CL
    Wang, K
    CHEMICAL ENGINEERING JOURNAL, 2001, 84 (03) : 381 - 388