Molten Salt Parabolic Trough System with Synthetic Oil Preheating

被引:4
|
作者
Yuasa, Minoru [1 ]
Hino, Koichi [1 ]
机构
[1] Chiyoda Corp, Nishi Ku, Minato Mirai Grand Cent Tower 4-6-2, Yokohama, Kanagawa 2208765, Japan
关键词
D O I
10.1063/1.4984343
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Molten salt parabolic trough system (MSPT), which can heat the heat transfer fluid (HTF) to 550 degrees C has a better performance than a synthetic oil parabolic trough system (SOPT), which can heat the HTF to 400 degrees C or less. The utilization of HTF at higher temperature in the parabolic trough system is able to realize the design of a smaller size of storage tank and higher heat to electricity conversion efficiency. However, with MSPT there is a great amount of heat loss at night so it is necessary to circulate the HTF at a high temperature of about 290 degrees C in order to prevent solidification. A new MSPT concept with SOPT preheating (MSSOPT) has been developed to reduce the heat loss at night. In this paper, the MSSOPT system, its performance by steady state analysis and annual performance analysis are introduced.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Corrosion monitoring of 321H in contact with a quaternary molten salt for parabolic trough CSP plants
    Encinas-Sanchez, V.
    Lasanta, M. I.
    de Miguel, M. T.
    Garcia-Martin, G.
    Perez, F. J.
    CORROSION SCIENCE, 2021, 178
  • [42] Effects of synthetic oil nanofluids and absorber geometries on the exergetic performance of the parabolic trough collector
    Okonkwo, Eric C.
    Abid, Muhammad
    Ratlamwala, Tahir A. H.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2018, 42 (11) : 3559 - 3574
  • [43] Thermo-economic analysis of a novel parabolic trough solar collector equipped with preheating system and canopy
    Yang, Liu
    Du, Kai
    ENERGY, 2020, 211 (211)
  • [44] Comparative system analysis of direct steam generation and synthetic oil parabolic trough power plants with integrated thermal storage
    Feldhoff, Jan Fabian
    Schmitz, Kai
    Eck, Markus
    Schnatbaum-Laumann, Lars
    Laing, Doerte
    Ortiz-Vives, Francisco
    Schulte-Fischedick, Jan
    SOLAR ENERGY, 2012, 86 (01) : 520 - 530
  • [45] COMPARATIVE SYSTEM ANALYSIS OF DIRECT STEAM GENERATION AND SYNTHETIC OIL PARABOLIC TROUGH POWER PLANTS WITH INTEGRATED THERMAL STORAGE
    Feldhoff, Jan Fabian
    Schmitz, Kai
    Eck, Markus
    Schnatbaum-Laumann, Lars
    Laing, Doerte
    Ortiz-Vives, Francisco
    Schulte-Fischedick, Jan
    PROCEEDINGS OF THE ASME 5TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY 2011, PTS A-C, 2012, : 631 - 640
  • [46] The influence of Solar Field inlet and outlet temperature on the cost of electricity in a Molten Salt Parabolic Trough Power Plant
    Richert, T.
    Riffelmann, K.
    Nava, P.
    INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, SOLARPACES 2014, 2015, 69 : 1143 - 1151
  • [47] Numerical investigation on the thermal performance of parabolic trough solar collector with synthetic oil/Cu nanofluids
    Dou, Lizhuang
    Ding, Bin
    Zhang, Qiang
    Kou, Guiyue
    Mu, Mingfei
    APPLIED THERMAL ENGINEERING, 2023, 227
  • [48] Conceptual Design of a 2x Trough for Use Within Salt and Oil-Based Parabolic Trough Power Plants
    Kolb, Gregory J.
    Diver, Richard B.
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (04):
  • [49] Study on optimization of preheating process of molten salt storage tank
    Yue S.
    Chen Y.
    Xiao H.
    Wang D.
    Li M.
    Zhang Y.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (10): : 113 - 118
  • [50] Comparison of Molten Salts and Thermal Oil in Parabolic Trough Power Plants for Different Sites and Different Storage Capacities
    Dersch, Juergen
    Wittmann, Michael Karl
    Hirsch, Tobias
    ENERGIES, 2025, 18 (02)