DETECTION OF DYSPLASTIC NEUTROPHILS WITH CELL POPULATION DATA ON THE UNICEL DXH800 COULTER CELLULAR ANALYSIS SYSTEM

被引:0
|
作者
Polyakova, E. [1 ]
Shtaprova, O. [1 ]
Cherednichenko, D. [1 ]
Sukhacheva, E. [2 ]
Mikhalevich, J. [3 ]
Simon, R. [2 ]
机构
[1] Pavlov State Med Univ, Ctr Lab Diagnost, St Petersburg, Russia
[2] Beckman Coulter Euroctr, Nyon, Switzerland
[3] Lab Tech Ltd, St Petersburg, Russia
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
引用
收藏
页码:S488 / S488
页数:1
相关论文
共 50 条
  • [41] EVALUATION OF THE BECKMAN COULTER UNICEL DXH 800, ABBOTT DIAGNOSTICS CELL-DYN SAPPHIRE AND SYSMEX XN 2000 HEMATOLOGY ANALYZERS IN A TERTIARY CARE HOSPITAL
    Rodriguez-Hernandez, Ines
    Galiano, Lucia
    Sierra, Isabel
    Castillo, Alicia
    Gonzalez, Filomena
    Vergara, Sara
    Raya, Minerva
    Vinyets, Esther
    Cinta Arnau, Maria
    Saez, Manuela
    Triguero, Miriam
    Barbera, Angels
    Junca, Jordi
    Milla, Fuensanta
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2013, 35 : 58 - 59
  • [42] EVALUATION OF NEWRED CELL PARAMETERS ON BECKMAN COULTER DXH800IN THE DETECTION OF IRON DEFICIENCY AND THALASSAEMIA CARRIER
    Ng, Esda H. Y.
    Leung, Junior H. W.
    Lau, Y. S.
    Ma, Edmond S. K.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2013, 35 : 56 - 56
  • [43] Evaluation of the Beckman Coulter UniCel DxH 800 and Abbott Diagnostics Cell-Dyn Sapphire Hematology Analyzers on Pediatric and Neonatal Specimens in a Tertiary Care Hospital
    Tan, Brent T.
    Nava, Armando J.
    George, Tracy I.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2011, 135 (06) : 929 - 938
  • [44] CASE REPORT: EARLY DETECTION OF CANDIDA PARAPSILOSIS IN PERIPHERAL BLOOD AS A RESULT OF A PERIPHERAL BLOOD SMEAR PERFORMED AFTER CYTOGRAPHIC CHANGES ON THE BECKMAN COULTER UNICEL DXH 800 HEMATOLOGY
    Lucis, Riccardo
    Poz, Donatella
    Poletto, Monica
    Puzzolante, Liliana
    Sartor, Assunta
    Curcio, Francesco
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2023, 45 : 108 - 108
  • [45] Automated Early Detection of Myelodysplastic Syndrome within the General Population Using the Research Parameters of Beckman-Coulter DxH 800 Hematology Analyzer
    Ravalet, Noemie
    Foucault, Amelie
    Picou, Frederic
    Gombert, Martin
    Renoult, Emmanuel
    Lejeune, Julien
    Vallet, Nicolas
    Lachot, Sebastien
    Rault, Emmanuelle
    Gyan, Emmanuel
    Bene, Marie C.
    Herault, Olivier
    CANCERS, 2021, 13 (03) : 1 - 13
  • [46] DIAGNOSIS OF SEPSIS IN INTENSIVE CARE; ROLE OF THE CELL POPULATION DATA OF THE HEMATOLOGY ANALYZER DXH 800 AND EXPRESSION OF CD64 ON NEUTROPHILS ANALYSED BY THE PLATFORM HEMATOFLOW
    Pradier, Olivier
    Dimoula, Katerina
    Kassengera, Zaina
    Vincent, Jean Louis
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 : 129 - 130
  • [47] SPURIOUS HEMOGLOBIN MEASUREMENT IN HYPERLIPIDEMIC SAMPLES: POPULATION STUDY TO OBTAIN CUT-OFF VALUES FOR RED BLOOD CELL INDICES FOR ITS DETECTION WITH THE BECKMAN COULTER DXH-800 ANALYZER.
    Bigorra, Laura
    Alonso, Xavier
    Larriba, Iciar
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 : 19 - 19
  • [48] SCREENING OF DYSPLASTIC NEUTROPHILS USING CELL POPULATION DATA USING SYSMEX XN-1000 ANALYZER
    Kim, Hyunjung
    Han, Eunhee
    Han, Kyungja
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 : 69 - 69
  • [49] Detection of monoclonal B-lymphocytosis: interest of cellular population data and CytoDiff™ analysis
    Vedrenne, Aurelie
    Devin, Clotilde
    Delcominette, Frederique
    Habarou, Florence
    Vasse, Marc
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (03) : E83 - E86
  • [50] Towards system genetics analysis of head and neck squamous cell carcinoma using the mouse model, cellular platform, and clinical human data
    Zohud, Osayd
    Lone, Iqbal M.
    Nashef, Aysar
    Iraqi, Fuad A.
    ANIMAL MODELS AND EXPERIMENTAL MEDICINE, 2023, 6 (06) : 537 - 558